Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
300 | Luft/Wasser | CTC / Sanyo 4,5 | 4.5 | 2011 | 130 | 2 | 7703.0 | 12238.0 | 3073 | 1.59 | 1834.0 | 2601.0 | 674 | 1.42 | 1319.0 | 2045.0 | 522 | 1.55 | 583.0 | 961.0 | 229 | 1.65 | 190.0 | 330.0 | 89 | 1.74 | 139.0 | 268.0 | 79 | 1.93 | 104.0 | 218.0 | 67 | 2.10 | 109.0 | 223.0 | 72 | 2.05 | 76.0 | 163.0 | 51 | 2.14 | 98.0 | 205.0 | 62 | 2.09 | 367.0 | 647.0 | 169 | 1.76 | 1190.0 | 1975.0 | 459 | 1.66 | 1694.0 | 2602.0 | 600 | 1.54 | ||||||||||||
300 | Luft/Wasser | CTC / Sanyo 4,5 | 4.5 | 2010 | 130 | 2 | 8297.0 | 5383.0 | 3261 | 1.50 | 2300.0 | 744 | 1039.0 | 422 | 749.0 | 294 | 427.0 | 205 | 183.0 | 94 | 137.0 | 202.0 | 73 | 1.47 | 72.0 | 172.0 | 49 | 2.39 | 71.0 | 166.0 | 43 | 2.34 | 68.0 | 159.0 | 39 | 2.34 | 530.0 | 942.0 | 247 | 1.78 | 811.0 | 1307.0 | 371 | 1.61 | 1910.0 | 2435.0 | 680 | 1.27 | ||||||||||||||||||||||
300 | Luft/Wasser | CTC / Sanyo 4,5 | 4.5 | 2009 | 130 | 2 | 3913 | 744 | 672 | 300 | 240 | 160 | 110 | 110 | 150 | 110 | 220 | 420 | 677 | |||||||||||||||||||||||||||||||||||||||||||||||||||
300 | Luft/Wasser | CTC / Sanyo 4,5 | 4.5 | 2008 | 130 | 2 | 792 | 48 | 744 |
NR | 300 |
Username | sailaway |
Einbaujahr der WP | 2008-11-28 |
PLZ des Wohnortes | A-913 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | CTC / Sanyo 4,5 |
modulierend | |
Leistung (0/35) | 4.5 kW |
berechneter Primärenergiebedarf | 42.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 52 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1200 Watt DB |
elektr. Verbrauch HP gem./DB | 70 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 130 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Seit 2012 neue WP, neue Anlage Nr:862 |