Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
3019 | Sole/Wasser | Nibe S1155-6 PC | 6.0 | 2024 | 200 | 2 | 905.7 | 4689.5 | 2074 | 5.18 | 380.7 | 1546.2 | 694 | 4.06 | 197.6 | 978.9 | 586 | 4.95 | 157.2 | 857.8 | 498 | 5.46 | 101.6 | 590.8 | 296 | 5.81 | 14.5 | 176.2 | 0 | 12.15 | 14.8 | 179.8 | 0 | 12.15 | 18.4 | 179.1 | 0 | 9.73 | 20.9 | 180.7 | 0 | 8.65 | ||||||||||||||||||||||||||||
3019 | Sole/Wasser | Nibe S1155-6 PC | 6.0 | 2023 | 200 | 2 | 1536.4 | 7884.8 | 3307 | 5.13 | 338.0 | 1428.1 | 642 | 4.23 | 292.3 | 1225.9 | 588 | 4.19 | 255.1 | 1049.4 | 483 | 4.11 | 146.4 | 759.4 | 342 | 5.19 | 23.5 | 249.5 | 15 | 10.62 | 20.3 | 239.0 | 0 | 11.77 | 19.6 | 164.6 | 0 | 8.40 | 20.0 | 158.6 | 0 | 7.93 | 16.9 | 165.0 | 0 | 9.76 | 49.9 | 265.1 | 89 | 5.31 | 158.0 | 964.0 | 484 | 6.10 | 196.4 | 1216.2 | 664 | 6.19 | ||||||||||||
3019 | Sole/Wasser | Nibe S1155-6 PC | 6.0 | 2022 | 200 | 2 | 1866.2 | 8453.3 | 3265 | 4.53 | 413.0 | 1667.0 | 711 | 4.04 | 326.0 | 1314.0 | 642 | 4.03 | 276.0 | 1238.0 | 515 | 4.49 | 143.0 | 703.0 | 265 | 4.92 | 35.2 | 233.0 | 6 | 6.62 | 30.9 | 229.0 | 0 | 7.41 | 28.1 | 212.0 | 0 | 7.54 | 21.7 | 213.0 | 0 | 9.82 | 31.9 | 211.2 | 37 | 6.62 | 46.2 | 191.1 | 39 | 4.14 | 149.2 | 754.0 | 387 | 5.05 | 365.0 | 1488.0 | 663 | 4.08 | ||||||||||||
3019 | Sole/Wasser | Nibe S1155-6 PC | 6.0 | 2021 | 200 | 2 | 2421.8 | 10809.7 | 4354 | 4.46 | 444.8 | 1844.5 | 747 | 4.15 | 352.1 | 1383.0 | 570 | 3.93 | 357.7 | 1498.1 | 622 | 4.19 | 311.0 | 1249.0 | 513 | 4.02 | 118.0 | 638.5 | 287 | 5.41 | 63.0 | 250.0 | 1 | 3.97 | 34.0 | 187.0 | 1 | 5.50 | 31.6 | 179.7 | 4 | 5.69 | 32.4 | 176.0 | 6 | 5.43 | 114.0 | 656.0 | 251 | 5.75 | 281.6 | 1306.9 | 647 | 4.64 | 281.6 | 1441.0 | 705 | 5.12 | ||||||||||||
3019 | Sole/Wasser | Nibe S1155-6 PC | 6.0 | 2020 | 200 | 2 | 601.8 | 2890.3 | 1337 | 4.80 | 83.0 | 452.1 | 186 | 5.45 | 202.8 | 1050.7 | 457 | 5.18 | 316.0 | 1387.5 | 694 | 4.39 |
NR | 3019 |
Username | jogi54 |
Einbaujahr der WP | 2020-10-10 |
PLZ des Wohnortes | 51063 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe S1155-6 PC |
modulierend | Ja |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 38.0 kWh/m²/anno |
WW über WP | teil |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 1.7 m |
Fläche | 19 m² |
Heizungsart | sonstige |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 60 Watt |
elektr. Verbrauch WQ P gem./DB | 140 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 34.0 °C |
Spreizung Heizkr. | 3.8 |
Heizflaeche | 200 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | eigener RGK senkrecht |
Bemerkungen | HTD senkrechter RGK, -1,0 bis -2,5m, ~38m aktive Grabenlänge. Außenwandheizung, siehe https://www.haustechnikdialog.de/Forum/t/139697/Reihenhaus-Sanierung-mit-Kuehlhauspaneelen-und-Fassadenheizung Strom incl. STA, FriWa und UVR, Wärme incl. pass. Kälte und STA WMZ teils intern, teils extern (STA etc.) |