| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3022 | Sole/Wasser | Junkers STM 60-1 | 5.8 | 2025 | 118 | 4 | 1165.7 | 4726.8 | 4.05 | 298.8 | 1267.0 | 4.24 | 262.5 | 1117.3 | 4.26 | 188.8 | 805.3 | 4.27 | 80.0 | 307.4 | 3.84 | 56.6 | 196.3 | 3.47 | 35.6 | 108.6 | 3.05 | 30.2 | 86.1 | 2.85 | 32.2 | 92.9 | 2.89 | 46.7 | 158.7 | 3.40 | 134.3 | 587.2 | 4.37 | |||||||||||||||||||||||||||||||
| 3022 | Sole/Wasser | Junkers STM 60-1 | 5.8 | 2024 | 118 | 4 | 1548.9 | 6369.6 | 4.11 | 285.7 | 1224.5 | 4.29 | 211.7 | 908.0 | 4.29 | 171.8 | 716.0 | 4.17 | 109.4 | 438.0 | 4.00 | 56.2 | 175.1 | 3.12 | 42.4 | 128.7 | 3.04 | 35.2 | 103.0 | 2.93 | 35.8 | 93.8 | 2.62 | 43.2 | 136.4 | 3.16 | 117.2 | 506.4 | 4.32 | 203.2 | 908.0 | 4.47 | 237.1 | 1031.7 | 4.35 | |||||||||||||||||||||||||
| 3022 | Sole/Wasser | Junkers STM 60-1 | 5.8 | 2023 | 118 | 4 | 1678.1 | 6978.4 | 4.16 | 266.2 | 1161.6 | 4.36 | 254.9 | 1090.5 | 4.28 | 217.0 | 915.6 | 4.22 | 144.4 | 615.4 | 4.26 | 63.8 | 226.7 | 3.55 | 36.3 | 106.3 | 2.93 | 37.6 | 111.3 | 2.96 | 39.1 | 117.2 | 3.00 | 35.6 | 106.0 | 2.98 | 127.4 | 543.2 | 4.26 | 206.7 | 906.3 | 4.38 | 249.1 | 1078.3 | 4.33 | |||||||||||||||||||||||||
| 3022 | Sole/Wasser | Junkers STM 60-1 | 5.8 | 2022 | 118 | 4 | 845.2 | 3490.1 | 4.13 | 42.0 | 136.0 | 3.24 | 31.6 | 91.0 | 2.88 | 31.7 | 93.8 | 2.96 | 79.6 | 318.0 | 3.99 | 122.1 | 525.0 | 4.30 | 220.4 | 966.4 | 4.38 | 317.8 | 1359.9 | 4.28 |
| NR | 3022 |
| Username | snakegott |
| Einbaujahr der WP | 2022-02-23 |
| PLZ des Wohnortes | 17498 |
| Bauart | Sole/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Junkers STM 60-1 |
| modulierend | Nein |
| Leistung (0/35) | 5.8 kW |
| berechneter Primärenergiebedarf | 31.3 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 43 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | 1 Erdbohrung |
| Tiefe | 99.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 0.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 118 m² |
| Lüftung | zenKWLWR |
| Personen | 4 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen |