Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
3093 | Luft/Wasser | Panasonic-WH-MDC05J3E5 | 5.0 | 2025 | 150 | 4 | 1010.0 | 3904.0 | 1196 | 3.87 | 535.0 | 2077.0 | 646 | 3.88 | 475.0 | 1827.0 | 550 | 3.85 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
3093 | Luft/Wasser | Panasonic-WH-MDC05J3E5 | 5.0 | 2024 | 150 | 4 | 2651.0 | 11606.0 | 3448 | 4.38 | 549.0 | 2086.0 | 655 | 3.80 | 318.6 | 1419.0 | 445 | 4.45 | 330.0 | 1418.0 | 416 | 4.30 | 219.0 | 1034.0 | 280 | 4.72 | 60.0 | 298.0 | 69 | 4.97 | 70.0 | 305.0 | 72 | 4.36 | 33.0 | 154.0 | 25 | 4.67 | 36.0 | 171.0 | 38 | 4.75 | 60.0 | 334.0 | 83 | 5.57 | 168.4 | 870.0 | 246 | 5.17 | 342.0 | 1517.0 | 485 | 4.44 | 465.0 | 2000.0 | 634 | 4.30 | ||||||||||||
3093 | Luft/Wasser | Panasonic-WH-MDC05J3E5 | 5.0 | 2023 | 150 | 4 | 2673.9 | 10774.0 | 3474 | 4.03 | 434.0 | 1677.0 | 560 | 3.86 | 388.4 | 1541.0 | 523 | 3.97 | 419.0 | 1628.0 | 548 | 3.89 | 262.1 | 1086.0 | 371 | 4.14 | 130.1 | 506.0 | 165 | 3.89 | 48.3 | 168.0 | 35 | 3.48 | 38.0 | 122.0 | 22 | 3.21 | 29.0 | 98.0 | 20 | 3.38 | 35.5 | 147.0 | 25 | 4.14 | 127.4 | 604.0 | 187 | 4.74 | 338.4 | 1446.0 | 443 | 4.27 | 423.7 | 1751.0 | 575 | 4.13 | ||||||||||||
3093 | Luft/Wasser | Panasonic-WH-MDC05J3E5 | 5.0 | 2022 | 150 | 4 | 977.0 | 3752.0 | 1155 | 3.84 | 50.0 | 207.0 | 60 | 4.14 | 112.5 | 508.0 | 159 | 4.52 | 291.4 | 1193.0 | 400 | 4.09 | 523.1 | 1844.0 | 536 | 3.53 | ||||||||||||||||||||||||||||||||||||||||||||
3093 | Luft/Wasser | Panasonic-WH-MDC05J3E5 | 5.0 | 150 |
NR | 3093 |
Username | schletti |
Einbaujahr der WP | 2022-09-20 |
PLZ des Wohnortes | 49152 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Panasonic-WH-MDC05J3E5 |
modulierend | Ja |
Leistung (0/35) | 5.0 kW |
berechneter Primärenergiebedarf | 75.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 44 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | extern_geeicht |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 40.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 150 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |