| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3094 | Sole/Wasser | Nibe S1255-6 PC | 5.0 | 2026 | 173 | 4 | 207.1 | 1032.1 | 310 | 4.98 | 207.1 | 1032.1 | 310 | 4.98 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 3094 | Sole/Wasser | Nibe S1255-6 PC | 5.0 | 2025 | 173 | 4 | 2414.7 | 12530.6 | 4882 | 5.19 | 475.7 | 2595.1 | 797 | 5.46 | 409.2 | 2167.3 | 705 | 5.30 | 322.4 | 1630.6 | 603 | 5.06 | 182.7 | 934.7 | 410 | 5.12 | 82.5 | 300.0 | 148 | 3.64 | 66.2 | 157.0 | 87 | 2.37 | 64.5 | 62.3 | 40 | 0.97 | 67.7 | 97.8 | 64 | 1.44 | 63.7 | 199.6 | 109 | 3.13 | 139.9 | 980.6 | 481 | 7.01 | 225.9 | 1501.8 | 651 | 6.65 | 314.3 | 1903.8 | 787 | 6.06 | ||||||||||||
| 3094 | Sole/Wasser | Nibe S1255-6 PC | 5.0 | 2024 | 173 | 4 | 2050.1 | 11148.5 | 4255 | 5.44 | 472.2 | 2545.8 | 790 | 5.39 | 311.8 | 1830.6 | 738 | 5.87 | 182.8 | 1040.4 | 440 | 5.69 | 57.0 | 108.2 | 59 | 1.90 | 62.1 | 135.7 | 79 | 2.19 | 63.0 | 67.5 | 41 | 1.07 | 73.2 | 99.6 | 66 | 1.36 | 73.7 | 289.5 | 143 | 3.93 | 124.8 | 875.4 | 386 | 7.01 | 252.4 | 1845.8 | 721 | 7.31 | 377.1 | 2310.0 | 792 | 6.13 | ||||||||||||||||
| 3094 | Sole/Wasser | Nibe S1255-6 PC | 5.0 | 2023 | 173 | 4 | 2578.2 | 13997.5 | 5152 | 5.43 | 473.4 | 2703.2 | 738 | 5.71 | 389.5 | 2152.8 | 671 | 5.53 | 392.1 | 2117.8 | 1014 | 5.40 | 277.6 | 1531.5 | 618 | 5.52 | 79.8 | 272.5 | 125 | 3.41 | 50.6 | 70.3 | 44 | 1.39 | 66.7 | 113.6 | 1.70 | 62.0 | 118.1 | 1.90 | 62.0 | 143.6 | 79 | 2.32 | 120.2 | 764.4 | 330 | 6.36 | 247.7 | 1793.7 | 735 | 7.24 | 356.6 | 2216.0 | 798 | 6.21 | ||||||||||||||
| 3094 | Sole/Wasser | Nibe S1255-6 PC | 5.0 | 2022 | 173 | 4 | 955.1 | 5842.4 | 1775 | 6.12 | 88.0 | 447.0 | 252 | 5.08 | 122.0 | 951.0 | 217 | 7.80 | 273.0 | 1826.0 | 601 | 6.69 | 472.1 | 2618.4 | 705 | 5.55 |
| NR | 3094 |
| Username | fritzemann |
| Einbaujahr der WP | 2022-09-17 |
| PLZ des Wohnortes | 51491 |
| Bauart | Sole/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Nibe S1255-6 PC |
| modulierend | Ja |
| Leistung (0/35) | 5.0 kW |
| berechneter Primärenergiebedarf | 20.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 47 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Grabenkollektor |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH und Wandheizung |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 21.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 28.0 °C |
| Spreizung Heizkr. | 3.0 |
| Heizflaeche | 173 m² |
| Lüftung | zenKWLWR |
| Personen | 4 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | 1x als Helfer und 1x fuer Eigenheim |
| Bemerkungen | Anlage seit knapp einem Monat in Betrieb. HA und TA fehlt noch. Interner WMZ der Nibe, dafür extra Eastron Stromzähler installiert. |