Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3103 | Luft/Wasser | Panasonic WH-MDC05J3E5 | 5.0 | 2025 | 98 | 2 | 1221.0 | 5619.0 | 4.60 | 297.0 | 1315.0 | 4.43 | 293.0 | 1214.0 | 4.14 | 199.0 | 950.0 | 4.77 | 81.0 | 411.0 | 5.07 | 75.0 | 402.0 | 5.36 | 32.0 | 126.0 | 3.94 | 32.0 | 119.0 | 3.72 | 34.0 | 128.0 | 3.76 | 45.0 | 220.0 | 4.89 | 133.0 | 734.0 | 5.52 | |||||||||||||||||||||||||||||||
| 3103 | Luft/Wasser | Panasonic WH-MDC05J3E5 | 5.0 | 2024 | 98 | 2 | 1567.0 | 7568.0 | 4.83 | 333.0 | 1390.0 | 4.17 | 198.0 | 1027.0 | 5.19 | 174.0 | 902.0 | 5.18 | 115.0 | 601.0 | 5.23 | 38.0 | 185.0 | 4.87 | 33.0 | 151.0 | 4.58 | 30.0 | 125.0 | 4.17 | 29.0 | 118.0 | 4.07 | 41.0 | 218.0 | 5.32 | 108.0 | 637.0 | 5.90 | 213.0 | 1035.0 | 4.86 | 255.0 | 1179.0 | 4.62 | |||||||||||||||||||||||||
| 3103 | Luft/Wasser | Panasonic WH-MDC05J3E5 | 5.0 | 2023 | 98 | 2 | 1666.0 | 7802.0 | 4.68 | 271.0 | 1230.0 | 4.54 | 264.0 | 1155.0 | 4.38 | 229.0 | 1079.0 | 4.71 | 152.0 | 804.0 | 5.29 | 51.0 | 257.0 | 5.04 | 31.0 | 123.0 | 3.97 | 30.0 | 121.0 | 4.03 | 31.0 | 120.0 | 3.87 | 26.0 | 94.0 | 3.62 | 107.0 | 607.0 | 5.67 | 205.0 | 996.0 | 4.86 | 269.0 | 1216.0 | 4.52 | |||||||||||||||||||||||||
| 3103 | Luft/Wasser | Panasonic WH-MDC05J3E5 | 5.0 | 2022 | 98 | 2 | 697.0 | 3117.0 | 4.47 | 14.0 | 49.0 | 3.50 | 62.0 | 288.0 | 4.65 | 96.0 | 511.0 | 5.32 | 200.0 | 931.0 | 4.66 | 325.0 | 1338.0 | 4.12 |
| NR | 3103 |
| Username | JockelBln |
| Einbaujahr der WP | 2022-08-16 |
| PLZ des Wohnortes | 12683 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Panasonic WH-MDC05J3E5 |
| modulierend | Ja |
| Leistung (0/35) | 5.0 kW |
| berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 45 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | extern_geeicht |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 32.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 98 m² |
| Lüftung | Fenster |
| Personen | 2 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen |