Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
3147 | Luft/Wasser | Nibe 2120-12 | 9.0 | 2024 | 234 | 5 | 1306.0 | 5952.0 | 1814 | 4.56 | 427.0 | 1882.0 | 518 | 4.41 | 263.0 | 1337.0 | 419 | 5.08 | 226.0 | 1139.0 | 364 | 5.04 | 163.0 | 764.0 | 240 | 4.69 | 62.0 | 227.0 | 78 | 3.66 | 60.0 | 216.0 | 75 | 3.60 | 56.0 | 206.0 | 66 | 3.68 | 49.0 | 181.0 | 54 | 3.69 | ||||||||||||||||||||||||||||
3147 | Luft/Wasser | Nibe 2120-12 | 9.0 | 2023 | 234 | 4 | 2096.0 | 9804.0 | 2882 | 4.68 | 297.0 | 1417.0 | 402 | 4.77 | 335.0 | 1552.0 | 454 | 4.63 | 278.0 | 1319.0 | 385 | 4.74 | 208.0 | 1041.0 | 308 | 5.00 | 83.0 | 359.0 | 114 | 4.33 | 58.0 | 222.0 | 69 | 3.83 | 61.0 | 229.0 | 72 | 3.75 | 58.0 | 227.0 | 71 | 3.91 | 57.0 | 218.0 | 64 | 3.82 | 96.0 | 450.0 | 127 | 4.69 | 227.0 | 1120.0 | 313 | 4.93 | 338.0 | 1650.0 | 503 | 4.88 | ||||||||||||
3147 | Luft/Wasser | Nibe 2120-12 | 9.0 | 2022 | 234 | 4 | 1944.0 | 9102.0 | 2591 | 4.68 | 325.0 | 1541.0 | 436 | 4.74 | 258.0 | 1302.0 | 396 | 5.05 | 226.0 | 1138.0 | 316 | 5.04 | 172.0 | 861.0 | 245 | 5.01 | 71.0 | 275.0 | 90 | 3.87 | 53.0 | 202.0 | 64 | 3.81 | 52.0 | 194.0 | 60 | 3.73 | 51.0 | 185.0 | 56 | 3.63 | 78.0 | 348.0 | 104 | 4.46 | 95.0 | 440.0 | 135 | 4.63 | 198.0 | 996.0 | 274 | 5.03 | 365.0 | 1620.0 | 415 | 4.44 | ||||||||||||
3147 | Luft/Wasser | Nibe 2120-12 | 9.0 | 2021 | 234 | 4 | 2368.0 | 10835.0 | 2948 | 4.58 | 431.0 | 1941.0 | 487 | 4.50 | 373.0 | 1563.0 | 423 | 4.19 | 271.0 | 1320.0 | 320 | 4.87 | 224.0 | 1096.0 | 295 | 4.89 | 115.0 | 532.0 | 160 | 4.63 | 54.0 | 214.0 | 62 | 3.96 | 54.0 | 209.0 | 62 | 3.87 | 56.0 | 218.0 | 65 | 3.89 | 56.0 | 218.0 | 67 | 3.89 | 134.0 | 679.0 | 193 | 5.07 | 257.0 | 1251.0 | 377 | 4.87 | 343.0 | 1594.0 | 437 | 4.65 | ||||||||||||
3147 | Luft/Wasser | Nibe 2120-12 | 9.0 | 2020 | 234 | 3 | 2242.0 | 8857.0 | 2174 | 3.95 | 399.0 | 1569.0 | 375 | 3.93 | 363.0 | 1604.0 | 370 | 4.42 | 330.0 | 1404.0 | 297 | 4.25 | 126.0 | 434.0 | 85 | 3.44 | 90.0 | 248.0 | 77 | 2.76 | 62.0 | 158.0 | 46 | 2.55 | 57.0 | 136.0 | 39 | 2.39 | 52.0 | 123.0 | 33 | 2.37 | 58.0 | 129.0 | 39 | 2.22 | 147.0 | 451.0 | 183 | 3.07 | 215.0 | 965.0 | 250 | 4.49 | 343.0 | 1636.0 | 380 | 4.77 | ||||||||||||
3147 | Luft/Wasser | Nibe 2120-12 | 9.0 | 2019 | 234 | 3 | 2513.0 | 10121.0 | 2221 | 4.03 | 499.0 | 1901.0 | 463 | 3.81 | 215.0 | 1077.0 | 209 | 5.01 | 281.0 | 1223.0 | 254 | 4.35 | 185.0 | 730.0 | 171 | 3.95 | 162.0 | 476.0 | 124 | 2.94 | 58.0 | 201.0 | 34 | 3.47 | 59.0 | 206.0 | 35 | 3.49 | 62.0 | 227.0 | 37 | 3.66 | 77.0 | 268.0 | 44 | 3.48 | 180.0 | 645.0 | 162 | 3.58 | 337.0 | 1391.0 | 301 | 4.13 | 398.0 | 1776.0 | 387 | 4.46 |
NR | 3147 |
Username | PLZ47665 |
Einbaujahr der WP | 2018-11-22 |
PLZ des Wohnortes | 47665 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe 2120-12 |
modulierend | Ja |
Leistung (0/35) | 9.0 kW |
berechneter Primärenergiebedarf | 45.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 500 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 234 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Warmwasser per Zeitfenster möglichst zwischen 10:30 - 14:00 Uhr, Heizen mit Tag +1 von 9:00 - 19:00 Uhr, und Nacht -1 von 21:00 - 7:00 Uhr. PV mit 7,1 kWp (leider ging nicht mehr) ohne Speicher. Gesamte Autarkie ca. 43% (somit PV Unterstützung der WP mindestens 50%) |