Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3166 | Luft/Wasser | Daikin Altherma 3R ECH2O 6kW 500L Speicher | 6.0 | 2025 | 140 | 2 | 2111.0 | 8365.0 | 2216 | 3.96 | 485.0 | 1752.0 | 614 | 3.61 | 398.0 | 1381.0 | 443 | 3.47 | 241.0 | 1002.0 | 194 | 4.16 | 131.0 | 557.0 | 88 | 4.25 | 69.0 | 244.0 | 41 | 3.54 | 89.0 | 453.0 | 114 | 5.09 | 77.0 | 419.0 | 97 | 5.44 | 78.0 | 370.0 | 86 | 4.74 | 75.0 | 245.0 | 38 | 3.27 | 161.0 | 730.0 | 125 | 4.53 | 307.0 | 1212.0 | 376 | 3.95 | ||||||||||||||||
| 3166 | Luft/Wasser | Daikin Altherma 3R ECH2O 6kW 500L Speicher | 6.0 | 2024 | 140 | 2 | 2384.0 | 9744.0 | 2707 | 4.09 | 476.0 | 1730.0 | 555 | 3.63 | 258.0 | 1148.0 | 305 | 4.45 | 225.0 | 1020.0 | 211 | 4.53 | 173.0 | 752.0 | 149 | 4.35 | 66.0 | 213.0 | 36 | 3.23 | 63.0 | 241.0 | 49 | 3.83 | 82.0 | 419.0 | 100 | 5.11 | 89.0 | 489.0 | 117 | 5.49 | 76.0 | 303.0 | 67 | 3.99 | 140.0 | 612.0 | 120 | 4.37 | 288.0 | 1198.0 | 370 | 4.16 | 448.0 | 1619.0 | 628 | 3.61 | ||||||||||||
| 3166 | Luft/Wasser | Daikin Altherma 3R ECH2O 6kW 500L Speicher | 6.0 | 2023 | 140 | 2 | 2327.0 | 9454.0 | 3098 | 4.06 | 421.0 | 1594.0 | 640 | 3.79 | 357.0 | 1387.0 | 510 | 3.89 | 295.0 | 1233.0 | 434 | 4.18 | 195.0 | 837.0 | 212 | 4.29 | 58.0 | 164.0 | 28 | 2.83 | 75.0 | 331.0 | 76 | 4.41 | 59.0 | 284.0 | 66 | 4.81 | 68.0 | 297.0 | 62 | 4.37 | 62.0 | 237.0 | 47 | 3.82 | 120.0 | 522.0 | 149 | 4.35 | 258.0 | 1132.0 | 371 | 4.39 | 359.0 | 1436.0 | 503 | 4.00 | ||||||||||||
| 3166 | Luft/Wasser | Daikin Altherma 3R ECH2O 6kW 500L Speicher | 6.0 | 2022 | 140 | 2 | 1565.0 | 6307.0 | 4.03 | 299.0 | 1501.0 | 5.02 | 93.0 | 267.0 | 2.87 | 51.0 | 134.0 | 2.63 | 68.0 | 274.0 | 4.03 | 124.0 | 567.0 | 4.57 | 76.0 | 245.0 | 3.22 | 120.0 | 516.0 | 4.30 | 245.0 | 1065.0 | 4.35 | 489.0 | 1738.0 | 3.55 |
| NR | 3166 |
| Username | stasihasi |
| Einbaujahr der WP | 2022-04-01 |
| PLZ des Wohnortes | 66773 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Daikin Altherma 3R ECH2O 6kW 500L Speicher |
| modulierend | Ja |
| Leistung (0/35) | 6.0 kW |
| berechneter Primärenergiebedarf | 35.8 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 47 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 22.5 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 35.0 °C |
| Spreizung Heizkr. | 2.0 |
| Heizflaeche | 140 m² |
| Lüftung | Fenster |
| Personen | 2 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Baugleich mit Rotex HPSU Compact 508 (aufgekauft von Daikin) - Im Sommer wird mit der Wärmepumpe gekühlt • Kühlleistung nom. A35 / W18: 5,96 kW - Herstellerangaben Wirkungsgrad: • COP A-7 / W35: 2,90 • COP A2 / W35: 3,75 • COP A7 / W35: 4,85 • COP A10 / W35: 5,15 |