Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
3183 | Wasser/Wasser | Alpha Innotec SWCV 122H3 | 14.0 | 2025 | 250 | 5 | 984.0 | 4093.0 | 730 | 4.16 | 984.0 | 4093.0 | 730 | 4.16 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
3183 | Wasser/Wasser | Alpha Innotec SWCV 122H3 | 14.0 | 2024 | 250 | 5 | 5697.0 | 24369.0 | 4606 | 4.28 | 968.0 | 4136.0 | 738 | 4.27 | 647.0 | 3364.0 | 693 | 5.20 | 602.0 | 3271.0 | 669 | 5.43 | 498.0 | 2566.0 | 530 | 5.15 | 577.0 | 963.0 | 171 | 1.67 | 352.0 | 366.0 | 36 | 1.04 | 79.0 | 254.0 | 29 | 3.22 | 68.0 | 245.0 | 26 | 3.60 | 164.0 | 738.0 | 101 | 4.50 | 346.0 | 1449.0 | 239 | 4.19 | 597.0 | 3006.0 | 632 | 5.04 | 799.0 | 4011.0 | 742 | 5.02 | ||||||||||||
3183 | Wasser/Wasser | Alpha Innotec SWCV 122H3 | 14.0 | 2023 | 250 | 5 | 5007.0 | 24296.0 | 4455 | 4.85 | 835.0 | 3949.0 | 729 | 4.73 | 882.0 | 3539.0 | 668 | 4.01 | 685.0 | 3446.0 | 705 | 5.03 | 514.0 | 2801.0 | 553 | 5.45 | 249.0 | 1128.0 | 179 | 4.53 | 93.0 | 357.0 | 44 | 3.84 | 72.0 | 285.0 | 34 | 3.96 | 88.0 | 357.0 | 43 | 4.06 | 114.0 | 460.0 | 56 | 4.04 | 258.0 | 1233.0 | 177 | 4.78 | 496.0 | 2938.0 | 529 | 5.92 | 721.0 | 3803.0 | 738 | 5.27 | ||||||||||||
3183 | Wasser/Wasser | Alpha Innotec SWCV 122H3 | 14.0 | 2022 | 250 | 5 | 3369.0 | 15344.0 | 2467 | 4.55 | 422.0 | 1247.0 | 223 | 2.95 | 635.0 | 3105.0 | 539 | 4.89 | 433.0 | 1943.0 | 250 | 4.49 | 194.0 | 773.0 | 89 | 3.98 | 81.0 | 350.0 | 29 | 4.32 | 81.0 | 380.0 | 28 | 4.69 | 69.0 | 290.0 | 28 | 4.20 | 118.0 | 470.0 | 59 | 3.98 | 189.0 | 1200.0 | 110 | 6.35 | 410.0 | 1809.0 | 376 | 4.41 | 737.0 | 3777.0 | 736 | 5.12 |
NR | 3183 |
Username | rSSamSee |
Einbaujahr der WP | 2022-02-08 |
PLZ des Wohnortes | 79279 |
Bauart | Wasser/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Alpha Innotec SWCV 122H3 |
modulierend | Ja |
Leistung (0/35) | 14.0 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 49 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Förder- und Schluckbrunnen |
Tiefe | 16.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 5000 Watt gem. |
elektr. Verbrauch HP gem./DB | 35 Watt |
elektr. Verbrauch WQ P gem./DB | 75 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 12.0 °C |
Heizung max. Vorlauf Temp. | 45.0 °C |
Spreizung Heizkr. | 10.0 |
Heizflaeche | 250 m² |
Lüftung | Fenster |
Personen | 5 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Freistehendes Haus. Baujahr 1972 Energetische Sanierung 2006. Brunnen mit Saugheber Lösung mit Trinkwasserpumpe Magna 3 25-80 N. von 2006 bis 15.12.2021 Nibe 1250 ohne WMZ Verbrauch im ø 6700 kWh. Neue WP seit 18.02.2022 im Einsatz. Die WMZ Daten stimmen im Monat nicht alle. Habe bei fehlenden Monatsdaten geschätzt. Die Wärmemenge im Jahr 2022 = 15150 kWh, Stromverbrauch seit 18.02 = 3369 kWh. |