Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3224 | Luft/Wasser | Daikin Altherma 3 R Ech20 308508 HC H Biv 8 kW | 6.1 | 2025 | 110 | 2 | 3058.0 | 10695.0 | 4515 | 3.50 | 794.0 | 2603.0 | 862 | 3.28 | 397.0 | 1352.0 | 561 | 3.41 | 313.0 | 1075.0 | 686 | 3.43 | 150.0 | 502.0 | 229 | 3.35 | 87.0 | 239.0 | 60 | 2.75 | 52.0 | 109.0 | 16 | 2.10 | 61.0 | 180.0 | 27 | 2.95 | 43.0 | 156.0 | 21 | 3.63 | 94.0 | 365.0 | 122 | 3.88 | 228.0 | 959.0 | 554 | 4.21 | 348.0 | 1312.0 | 636 | 3.77 | 491.0 | 1843.0 | 741 | 3.75 | ||||||||||||
| 3224 | Luft/Wasser | Daikin Altherma 3 R Ech20 308508 HC H Biv 8 kW | 6.1 | 2024 | 110 | 2 | 2921.0 | 10231.0 | 4547 | 3.50 | 650.0 | 2106.0 | 734 | 3.24 | 325.0 | 1256.0 | 675 | 3.86 | 270.0 | 1038.0 | 521 | 3.84 | 237.0 | 896.0 | 374 | 3.78 | 67.0 | 213.0 | 53 | 3.18 | 62.0 | 137.0 | 19 | 2.21 | 62.0 | 130.0 | 19 | 2.10 | 68.0 | 149.0 | 21 | 2.19 | 81.0 | 298.0 | 109 | 3.68 | 231.0 | 899.0 | 598 | 3.89 | 367.0 | 1294.0 | 666 | 3.53 | 501.0 | 1815.0 | 758 | 3.62 | ||||||||||||
| 3224 | Luft/Wasser | Daikin Altherma 3 R Ech20 308508 HC H Biv 8 kW | 6.1 | 2023 | 110 | 2 | 2851.0 | 9890.0 | 4257 | 3.47 | 515.0 | 1609.0 | 700 | 3.12 | 440.0 | 1562.0 | 600 | 3.55 | 409.0 | 1372.0 | 460 | 3.35 | 243.0 | 825.0 | 506 | 3.40 | 103.0 | 294.0 | 182 | 2.85 | 60.0 | 135.0 | 19 | 2.25 | 60.0 | 150.0 | 22 | 2.50 | 59.0 | 189.0 | 22 | 3.20 | 45.0 | 99.0 | 22 | 2.20 | 182.0 | 693.0 | 368 | 3.81 | 319.0 | 1284.0 | 626 | 4.03 | 416.0 | 1678.0 | 730 | 4.03 |
| NR | 3224 |
| Username | horstman |
| Einbaujahr der WP | 2022-07-01 |
| PLZ des Wohnortes | 42799 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Daikin Altherma 3 R Ech20 308508 HC H Biv 8 kW |
| modulierend | Ja |
| Leistung (0/35) | 6.1 kW |
| berechneter Primärenergiebedarf | 83.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 42 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | Radiatoren |
| elektr. Verbrauch WP ohne NA gem./DB | 18 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 23.0 °C |
| Mittlere Wärmequellentemperatur | 11.0 °C |
| Heizung max. Vorlauf Temp. | 40.0 °C |
| Spreizung Heizkr. | 5.0 |
| Heizflaeche | 110 m² |
| Lüftung | dezKWLWR |
| Personen | 2 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Mittleres Reihenhaus Baujahr 1999. Installiert mit Soundcover und Zirkulationspumpe. Reserveheizung ab -10° möglich. Neue Bedienoberfläche Daikin 2022. Ab Januar 2023 wird der Stromverbrauch mit einem geeichten 3Phasenzähler ermittelt. |