Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3225 | Sole/Wasser | Nibe S1155 PC | 6.0 | 2025 | 240 | 3 | 1296.0 | 8297.0 | 6.40 | 245.0 | 1721.0 | 0 | 7.02 | 223.0 | 1432.0 | 0 | 6.42 | 152.0 | 860.0 | 0 | 5.66 | 70.0 | 321.0 | 0 | 4.59 | 50.0 | 219.0 | 0 | 4.38 | 47.0 | 204.0 | 0 | 4.34 | 44.0 | 199.0 | 0 | 4.52 | 53.0 | 240.0 | 0 | 4.53 | 32.0 | 178.0 | 0 | 5.56 | 65.0 | 534.0 | 0 | 8.22 | 125.0 | 1000.0 | 0 | 8.00 | 190.0 | 1389.0 | 7.31 | ||||||||||||||
| 3225 | Sole/Wasser | Nibe S1155 PC | 6.0 | 2024 | 240 | 3 | 1318.0 | 7982.0 | 2180 | 6.06 | 286.0 | 1675.0 | 735 | 5.86 | 194.0 | 1069.0 | 628 | 5.51 | 162.0 | 879.0 | 521 | 5.43 | 98.0 | 588.0 | 296 | 6.00 | 58.0 | 226.0 | 0 | 3.90 | 37.0 | 158.0 | 0 | 4.27 | 33.0 | 157.0 | 0 | 4.76 | 42.0 | 197.0 | 0 | 4.69 | 37.0 | 190.0 | 0 | 5.14 | 50.0 | 342.0 | 0 | 6.84 | 133.0 | 1087.0 | 0 | 8.17 | 188.0 | 1414.0 | 0 | 7.52 | ||||||||||||
| 3225 | Sole/Wasser | Nibe S1155 PC | 6.0 | 2023 | 240 | 3 | 1688.0 | 9787.0 | 4228 | 5.80 | 328.0 | 2024.0 | 0 | 6.17 | 311.0 | 1677.0 | 0 | 5.39 | 250.0 | 1371.0 | 0 | 5.48 | 48.0 | 279.0 | 0 | 5.81 | 91.0 | 354.0 | 0 | 3.89 | 71.0 | 314.0 | 0 | 4.42 | 72.0 | 348.0 | 0 | 4.83 | 64.0 | 311.0 | 0 | 4.86 | 50.0 | 241.0 | 0 | 4.82 | 57.0 | 330.0 | 0 | 5.79 | 124.0 | 1050.0 | 0 | 8.47 | 222.0 | 1488.0 | 4228 | 6.70 |
| NR | 3225 |
| Username | SilvioK |
| Einbaujahr der WP | 2023-01-12 |
| PLZ des Wohnortes | 48485 |
| Bauart | Sole/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Nibe S1155 PC |
| modulierend | Ja |
| Leistung (0/35) | 6.0 kW |
| berechneter Primärenergiebedarf | 12.5 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 50 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Grabenkollektor |
| Tiefe | 1.7 m |
| Fläche | 1 m² |
| Heizungsart | FBH und Wandheizung |
| elektr. Verbrauch WP ohne NA gem./DB | 1400 Watt DB |
| elektr. Verbrauch HP gem./DB | 60 Watt |
| elektr. Verbrauch WQ P gem./DB | 140 Watt |
| Stromzähler | intern > erfasst: Kompressor |
| WMZ | intern |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 10.0 °C |
| Heizung max. Vorlauf Temp. | 27.0 °C |
| Spreizung Heizkr. | 3.0 |
| Heizflaeche | 240 m² |
| Lüftung | zenKWL |
| Personen | 3 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | Keine |
| Bemerkungen |