Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2025 | 189 | 2 | 881.8 | 3276.0 | 3.72 | 491.8 | 1824.0 | 3.71 | 390.0 | 1452.0 | 3.72 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2024 | 189 | 2 | 2067.3 | 8549.0 | 4.14 | 539.0 | 1985.0 | 3.68 | 270.5 | 1207.0 | 4.46 | 227.4 | 1009.0 | 4.44 | 144.1 | 611.0 | 4.24 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 59.9 | 232.0 | 3.87 | 140.3 | 658.0 | 4.69 | 318.6 | 1326.0 | 4.16 | 367.1 | 1519.0 | 4.14 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2023 | 189 | 2 | 2099.5 | 8679.0 | 4.13 | 422.7 | 1707.0 | 4.04 | 331.9 | 1342.0 | 4.04 | 300.8 | 1226.0 | 4.08 | 149.9 | 616.0 | 4.11 | 10.3 | 26.0 | 2.52 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 111.1 | 552.0 | 4.97 | 383.7 | 1604.0 | 4.18 | 388.7 | 1604.0 | 4.13 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2022 | 189 | 2 | 2108.2 | 8399.5 | 3.98 | 432.9 | 1716.0 | 3.96 | 316.1 | 1305.0 | 4.13 | 256.7 | 978.0 | 3.81 | 168.5 | 666.0 | 3.95 | 7.9 | 20.0 | 2.53 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 37.0 | 170.0 | 4.59 | 87.8 | 434.0 | 4.94 | 276.1 | 1182.0 | 4.28 | 524.9 | 1927.0 | 3.67 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2021 | 189 | 2 | 2424.8 | 9610.9 | 3.96 | 485.5 | 1852.0 | 3.81 | 405.4 | 1437.0 | 3.54 | 262.5 | 1079.0 | 4.11 | 226.9 | 895.0 | 3.94 | 97.5 | 417.0 | 4.28 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 139.6 | 700.9 | 5.02 | 326.4 | 1426.0 | 4.37 | 480.6 | 1802.0 | 3.75 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2020 | 189 | 2 | 1708.0 | 7437.5 | 4.35 | 334.2 | 1384.0 | 4.14 | 267.0 | 1179.0 | 4.42 | 226.9 | 937.0 | 4.13 | 39.6 | 165.0 | 4.17 | 51.9 | 193.0 | 3.72 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 15.2 | 83.0 | 5.46 | 145.0 | 758.0 | 5.23 | 246.0 | 1115.0 | 4.53 | 381.9 | 1622.0 | 4.25 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2019 | 189 | 2 | 1939.9 | 8119.0 | 4.19 | 481.2 | 1828.0 | 3.80 | 265.5 | 1057.0 | 3.98 | 224.6 | 1058.0 | 4.71 | 82.9 | 336.0 | 4.05 | 57.8 | 256.0 | 4.43 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 122.3 | 573.0 | 4.69 | 374.3 | 1567.0 | 4.19 | 330.9 | 1442.0 | 4.36 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2018 | 189 | 2 | 2205.4 | 8706.0 | 3.95 | 423.8 | 1745.0 | 4.12 | 587.0 | 2021.0 | 3.44 | 400.3 | 1526.0 | 3.81 | 45.9 | 196.0 | 4.27 | 19.0 | 89.0 | 4.68 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 93.0 | 424.0 | 4.56 | 319.1 | 1340.0 | 4.20 | 316.9 | 1363.0 | 4.30 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2017 | 189 | 2 | 2857.7 | 11769.3 | 4.12 | 668.1 | 2707.0 | 4.05 | 459.8 | 1847.0 | 4.02 | 257.9 | 1113.0 | 4.32 | 254.4 | 1013.0 | 3.98 | 92.8 | 343.0 | 3.70 | 36.2 | 83.0 | 2.29 | 35.4 | 73.0 | 2.06 | 0.1 | 0.3 | 3.00 | 17.7 | 101.0 | 5.71 | 125.4 | 675.0 | 5.38 | 405.5 | 1789.0 | 4.41 | 504.4 | 2025.0 | 4.01 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2016 | 189 | 2 | 3206.9 | 12067.0 | 3.76 | 572.0 | 2079.0 | 3.63 | 459.8 | 1720.0 | 3.74 | 421.2 | 1600.0 | 3.80 | 232.0 | 897.0 | 3.87 | 78.7 | 246.0 | 3.13 | 34.9 | 68.0 | 1.95 | 42.0 | 108.0 | 2.57 | 39.1 | 88.0 | 2.25 | 41.1 | 101.0 | 2.46 | 245.2 | 1116.0 | 4.55 | 505.2 | 1975.0 | 3.91 | 535.7 | 2069.0 | 3.86 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2015 | 189 | 2 | 2880.9 | 11275.0 | 3.91 | 647.0 | 2410.0 | 3.72 | 489.9 | 1793.0 | 3.66 | 381.0 | 1509.0 | 3.96 | 223.0 | 860.0 | 3.86 | 130.3 | 504.0 | 3.87 | 45.7 | 134.0 | 2.93 | 37.0 | 62.0 | 1.68 | 49.0 | 129.0 | 2.63 | 90.0 | 336.0 | 3.73 | 228.0 | 1027.0 | 4.50 | 275.0 | 1204.0 | 4.38 | 285.0 | 1307.0 | 4.59 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2014 | 189 | 2 | 3161.7 | 11251.6 | 3.56 | 669.7 | 2360.0 | 3.52 | 478.3 | 1781.0 | 3.72 | 409.3 | 998.0 | 2.44 | 155.4 | 441.0 | 2.84 | 113.1 | 400.0 | 3.54 | 35.6 | 82.0 | 2.30 | 43.9 | 102.0 | 2.32 | 66.9 | 199.0 | 2.97 | 61.1 | 207.0 | 3.39 | 138.5 | 667.0 | 4.82 | 353.9 | 1652.6 | 4.67 | 636.0 | 2362.0 | 3.71 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2013 | 189 | 2 | 5551.7 | 18676.0 | 3.36 | 1046.8 | 3366.0 | 3.22 | 896.6 | 2983.0 | 3.33 | 918.1 | 2962.0 | 3.23 | 378.9 | 1379.0 | 3.64 | 235.8 | 1002.0 | 4.25 | 231.7 | 517.0 | 2.23 | 119.1 | 192.0 | 1.61 | 47.3 | 151.0 | 3.19 | 123.7 | 692.0 | 5.59 | 268.0 | 1054.0 | 3.93 | 595.7 | 2045.0 | 3.43 | 690.0 | 2333.0 | 3.38 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2012 | 189 | 2 | 4849.2 | 17033.0 | 3.51 | 847.9 | 2986.0 | 3.52 | 1062.5 | 3224.0 | 3.03 | 403.9 | 1605.0 | 3.97 | 319.8 | 1248.0 | 3.90 | 183.4 | 662.0 | 3.61 | 107.3 | 292.0 | 2.72 | 58.9 | 107.0 | 1.82 | 54.6 | 127.0 | 2.33 | 142.9 | 581.0 | 4.07 | 343.2 | 1363.0 | 3.97 | 553.9 | 2069.0 | 3.74 | 770.9 | 2769.0 | 3.59 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2011 | 189 | 2 | 3708.8 | 15875.2 | 4.28 | 641.2 | 3127.8 | 4.88 | 455.5 | 2475.0 | 5.43 | 425.9 | 2216.7 | 5.20 | 181.8 | 725.7 | 3.99 | 46.0 | 115.0 | 2.50 | 47.3 | 122.0 | 2.58 | 106.3 | 341.0 | 3.21 | 52.0 | 137.0 | 2.63 | 159.9 | 569.0 | 3.56 | 329.4 | 1297.0 | 3.94 | 629.1 | 2286.0 | 3.63 | 634.4 | 2463.0 | 3.88 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2010 | 189 | 2 | 6571.7 | 20379.5 | 3.10 | 1338.6 | 3138.3 | 2.34 | 1001.2 | 3079.4 | 3.08 | 626.2 | 2179.2 | 3.48 | 343.1 | 1243.8 | 3.63 | 325.3 | 1207.2 | 3.71 | 86.2 | 235.0 | 2.73 | 54.8 | 138.3 | 2.52 | 102.4 | 133.7 | 1.31 | 219.4 | 703.3 | 3.21 | 420.4 | 1463.0 | 3.48 | 718.3 | 2497.2 | 3.48 | 1335.8 | 4361.1 | 3.26 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2009 | 189 | 2 | 2290.5 | 6708.4 | 2.93 | 264.0 | 299.0 | 1.13 | 107.1 | 248.0 | 2.32 | 419.2 | 1383.6 | 3.30 | 429.9 | 1639.4 | 3.81 | 1070.3 | 3138.4 | 2.93 |
NR | 323 |
Username | Zwerius |
Einbaujahr der WP | 2009-06-18 |
PLZ des Wohnortes | NL-7631J |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Zubadan PUHZ-HRP 100 YHA |
modulierend | Ja |
Leistung (0/35) | 11.2 kW |
berechneter Primärenergiebedarf | 44.8 kWh/m²/anno |
WW über WP | Nein |
WW Temperatur | 52 °C |
WW Legionellenschaltung | Ja |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 3100 Watt DB |
elektr. Verbrauch HP gem./DB | 155 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | extern_geeicht |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 5.0 °C |
Heizung max. Vorlauf Temp. | 32.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 189 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Brauchwasserspeicher 120 liter, mit separater Wärmepumpe. Vorlauftemperatur der Heizung ist 25-32°C (Aussentemperaturgeregelt über PAC-IF021B-E), also ohne Mischventile. Das wasser vom WP geht direkt in die FBH. Wir haben kein Speicher und kein Kaminofen. Seit 15-02-2011 ist am Zubadan das Startpunkt der Flash-Injektion auf -3°C eingestellt (ab Werk ist +3°C eingestellt) um damit die AZ (bei Aussentemperaturen rund 0°C) weiter zu verbessern. Die guten Ergebnisse von Anfang 2011 wurden leider verursacht durch ein fehlerhaften kWh-Messung! Seit März 2014 ist ein PUHZ-SHW112YHA eingebaut. Wegen kaputte Verdampfer der erste Maschine (Garantie). Seit August 2017 haben wir eine separate Warm Wasser Wärmepumpe für Brauchwasser. Die daten sind seit dem also nur für Heizung. Bis Ende 2018 FBH und Radiatoren e-mail:z.kriegsman@gmail.com |