Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3282 | Luft/Wasser | Vaillant aroTHERM plus VWL 1256 A | 5.9 | 2025 | 275 | 5 | 5239.0 | 19220.0 | 3.67 | 926.0 | 3449.0 | 3.72 | 809.0 | 3064.0 | 3.79 | 648.0 | 2523.0 | 3.89 | 295.0 | 1124.0 | 3.81 | 171.0 | 486.0 | 2.84 | 101.0 | 215.0 | 2.13 | 94.0 | 201.0 | 2.14 | 95.0 | 203.0 | 2.14 | 106.0 | 282.0 | 2.66 | 337.0 | 1554.0 | 4.61 | 691.0 | 2576.0 | 3.73 | 966.0 | 3543.0 | 3.67 | |||||||||||||||||||||||||
| 3282 | Luft/Wasser | Vaillant aroTHERM plus VWL 1256 A | 5.9 | 2024 | 275 | 5 | 4712.0 | 16494.0 | 3.50 | 1042.0 | 3348.0 | 3.21 | 475.0 | 1908.0 | 4.02 | 419.0 | 1616.0 | 3.86 | 294.0 | 1052.0 | 3.58 | 160.0 | 443.0 | 2.77 | 126.0 | 291.0 | 2.31 | 117.0 | 252.0 | 2.15 | 115.0 | 245.0 | 2.13 | 138.0 | 362.0 | 2.62 | 231.0 | 824.0 | 3.57 | 665.0 | 2701.0 | 4.06 | 930.0 | 3452.0 | 3.71 | |||||||||||||||||||||||||
| 3282 | Luft/Wasser | Vaillant aroTHERM plus VWL 1256 A | 5.9 | 2023 | 275 | 5 | 4804.0 | 16835.0 | 3.50 | 903.0 | 3201.0 | 3.54 | 710.0 | 2581.0 | 3.64 | 541.0 | 1962.0 | 3.63 | 388.0 | 1572.0 | 4.05 | 181.0 | 586.0 | 3.24 | 115.0 | 258.0 | 2.24 | 115.0 | 261.0 | 2.27 | 118.0 | 279.0 | 2.36 | 119.0 | 280.0 | 2.35 | 182.0 | 565.0 | 3.10 | 609.0 | 2338.0 | 3.84 | 823.0 | 2952.0 | 3.59 | |||||||||||||||||||||||||
| 3282 | Luft/Wasser | Vaillant aroTHERM plus VWL 1256 A | 5.9 | 2022 | 275 | 5 | 5659.0 | 19906.0 | 3.52 | 1164.0 | 4002.0 | 3.44 | 776.0 | 2962.0 | 3.82 | 679.0 | 2503.0 | 3.69 | 440.0 | 1573.0 | 3.58 | 188.0 | 592.0 | 3.15 | 135.0 | 338.0 | 2.50 | 125.0 | 296.0 | 2.37 | 118.0 | 263.0 | 2.23 | 187.0 | 652.0 | 3.49 | 224.0 | 832.0 | 3.71 | 586.0 | 2335.0 | 3.98 | 1037.0 | 3558.0 | 3.43 |
| NR | 3282 |
| Username | makowaep |
| Einbaujahr der WP | 2021-07-07 |
| PLZ des Wohnortes | 86453 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Vaillant aroTHERM plus VWL 1256 A |
| modulierend | Ja |
| Leistung (0/35) | 5.9 kW |
| berechneter Primärenergiebedarf | 5.8 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 54 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 8000 Watt DB |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 50 Watt |
| Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 21.0 °C |
| Mittlere Wärmequellentemperatur | 3.1 °C |
| Heizung max. Vorlauf Temp. | 35.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 275 m² |
| Lüftung | zenKWLWR |
| Personen | 5 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Nicht bekannte Werte habe ich auf 0 belassen. Primärenergiebedarf gem. EnEV ist auf Sole-WP mit Grabenkollektor bezogen, der jedoch dann nicht umgesetzt wurde. Stromverbrauch und Wärmeertrag inkludieren kontrollierte Wohnraumlüftung und Nebenaggregate (Umwälzpumpen). |