Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
337 | Sole/Wasser | Alpha Innotec WZS 80H | 8.4 | 2012 | 125 | 1876.7 | 8468.0 | 937 | 4.51 | 362.3 | 1684.0 | 185 | 4.65 | 452.8 | 2006.8 | 228 | 4.43 | 280.5 | 1314.5 | 144 | 4.69 | 179.6 | 824.3 | 91 | 4.59 | 43.4 | 159.6 | 19 | 3.68 | 13.8 | 38.1 | 6 | 2.76 | 21.4 | 55.8 | 7 | 2.61 | 20.6 | 51.5 | 8 | 2.50 | 21.9 | 55.1 | 8 | 2.52 | 189.8 | 910.7 | 95 | 4.80 | 290.6 | 1367.6 | 146 | 4.71 | |||||||||||||||||
337 | Sole/Wasser | Alpha Innotec WZS 80H | 8.4 | 2011 | 125 | 2101.8 | 9765.3 | 1050 | 4.65 | 424.1 | 2047.9 | 216 | 4.83 | 387.2 | 1753.7 | 198 | 4.53 | 276.8 | 1293.2 | 133 | 4.67 | 123.6 | 573.1 | 63 | 4.64 | 72.6 | 315.5 | 34 | 4.35 | 13.6 | 37.2 | 4 | 2.74 | 19.8 | 50.4 | 7 | 2.55 | 18.8 | 50.3 | 7 | 2.68 | 14.5 | 40.7 | 6 | 2.81 | 124.0 | 606.5 | 61 | 4.89 | 270.7 | 1309.1 | 138 | 4.84 | 356.1 | 1687.7 | 183 | 4.74 | |||||||||||||
337 | Sole/Wasser | Alpha Innotec WZS 80H | 8.4 | 2010 | 125 | 1452.3 | 7043.0 | 731 | 4.85 | 175.6 | 715.8 | 91 | 4.08 | 126.2 | 575.6 | 62 | 4.56 | 33.5 | 126.1 | 15 | 3.76 | 16.9 | 47.2 | 6 | 2.79 | 16.5 | 47.9 | 7 | 2.90 | 63.3 | 295.9 | 30 | 4.67 | 196.1 | 990.9 | 101 | 5.05 | 321.2 | 1496.6 | 164 | 4.66 | 503.0 | 2747.0 | 255 | 5.46 |
NR | 337 |
Username | zergman |
Einbaujahr der WP | 2009-12-28 |
PLZ des Wohnortes | 01900 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Alpha Innotec WZS 80H |
modulierend | |
Leistung (0/35) | 8.4 kW |
berechneter Primärenergiebedarf | 63.1 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 70.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1910 Watt DB |
elektr. Verbrauch HP gem./DB | 80 Watt |
elektr. Verbrauch WQ P gem./DB | 100 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 20.0 °C |
Mittlere Wärmequellentemperatur | 5.0 °C |
Heizung max. Vorlauf Temp. | 33.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 125 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |