| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3723 | Luft/Wasser | Viessmann Vitocal 200-S 201.D09 | 7.3 | 2025 | 215 | 4 | 5436.2 | 20197.9 | 3539 | 3.72 | 1185.1 | 3959.1 | 651 | 3.34 | 785.4 | 2900.5 | 572 | 3.69 | 535.9 | 2086.5 | 423 | 3.89 | 346.7 | 1411.5 | 226 | 4.07 | 241.2 | 947.8 | 127 | 3.93 | 85.3 | 302.2 | 33 | 3.54 | 58.6 | 180.3 | 15 | 3.08 | 77.8 | 248.9 | 18 | 3.20 | 127.7 | 515.3 | 78 | 4.04 | 388.2 | 1622.8 | 290 | 4.18 | 651.9 | 2474.4 | 514 | 3.80 | 952.4 | 3548.6 | 592 | 3.73 | ||||||||||||
| 3723 | Luft/Wasser | Viessmann Vitocal 200-S 201.D09 | 7.3 | 2024 | 215 | 4 | 5403.3 | 20075.0 | 3303 | 3.72 | 1157.1 | 3881.1 | 623 | 3.35 | 568.0 | 2251.3 | 391 | 3.96 | 513.4 | 2055.0 | 382 | 4.00 | 414.1 | 1635.8 | 276 | 3.95 | 201.4 | 869.1 | 91 | 4.32 | 142.8 | 585.4 | 73 | 4.10 | 94.8 | 346.6 | 34 | 3.66 | 98.2 | 340.9 | 26 | 3.47 | 148.1 | 601.4 | 85 | 4.06 | 338.7 | 1477.6 | 233 | 4.36 | 650.4 | 2379.6 | 450 | 3.66 | 1076.3 | 3651.2 | 639 | 3.39 | ||||||||||||
| 3723 | Luft/Wasser | Viessmann Vitocal 200-S 201.D09 | 7.3 | 2023 | 215 | 4 | 5488.9 | 21814.9 | 3554 | 3.97 | 1079.8 | 4127.0 | 620 | 3.82 | 857.2 | 3236.8 | 521 | 3.78 | 627.4 | 2518.9 | 538 | 4.01 | 483.8 | 2086.8 | 351 | 4.31 | 255.6 | 1197.3 | 143 | 4.68 | 76.4 | 273.0 | 34 | 3.57 | 87.0 | 334.7 | 37 | 3.85 | 113.2 | 485.8 | 44 | 4.29 | 116.3 | 499.4 | 58 | 4.29 | 279.9 | 1327.6 | 207 | 4.74 | 567.2 | 2275.9 | 464 | 4.01 | 945.1 | 3451.7 | 537 | 3.65 |
| NR | 3723 |
| Username | Deaddog |
| Einbaujahr der WP | 2021-06-01 |
| PLZ des Wohnortes | 35713 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Viessmann Vitocal 200-S 201.D09 |
| modulierend | Ja |
| Leistung (0/35) | 7.3 kW |
| berechneter Primärenergiebedarf | 33.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 48 °C |
| WW Legionellenschaltung | wöchentlich |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 5130 Watt DB |
| elektr. Verbrauch HP gem./DB | 60 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 21.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 40.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 215 m² |
| Lüftung | Fenster |
| Personen | 4 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen |