Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
3731 | Luft/Wasser | IDM iPump ALM 2-8 | 3.5 | 2024 | 254 | 2 | 1859.0 | 9931.0 | 2976 | 5.34 | 434.0 | 1978.0 | 620 | 4.56 | 220.0 | 1171.0 | 420 | 5.32 | 163.0 | 984.0 | 357 | 6.04 | 165.0 | 770.0 | 253 | 4.67 | 55.0 | 205.0 | 35 | 3.73 | 66.0 | 392.0 | 76 | 5.94 | 97.0 | 680.0 | 150 | 7.01 | 88.0 | 615.0 | 147 | 6.99 | 110.0 | 663.0 | 170 | 6.03 | 143.0 | 857.0 | 229 | 5.99 | 318.0 | 1616.0 | 519 | 5.08 | ||||||||||||||||
3731 | Luft/Wasser | IDM iPump ALM 2-8 | 3.5 | 2023 | 254 | 2 | 1850.0 | 10053.0 | 3227 | 5.43 | 353.0 | 1782.0 | 624 | 5.05 | 304.0 | 1457.0 | 545 | 4.79 | 203.0 | 1176.0 | 363 | 5.79 | 172.0 | 1036.0 | 317 | 6.02 | 64.0 | 344.0 | 87 | 5.38 | 68.0 | 596.0 | 147 | 8.76 | 47.0 | 323.0 | 84 | 6.87 | 24.0 | 117.0 | 17 | 4.88 | 21.0 | 107.0 | 20 | 5.10 | 39.0 | 176.0 | 40 | 4.51 | 200.0 | 1177.0 | 378 | 5.89 | 355.0 | 1762.0 | 605 | 4.96 | ||||||||||||
3731 | Luft/Wasser | IDM iPump ALM 2-8 | 3.5 | 2022 | 254 | 2 | 1826.0 | 8086.0 | 1729 | 4.43 | 240.0 | 935.0 | 212 | 3.90 | 246.0 | 982.0 | 216 | 3.99 | 107.0 | 414.0 | 73 | 3.87 | 118.0 | 685.0 | 108 | 5.81 | 127.0 | 717.0 | 128 | 5.65 | 133.0 | 671.0 | 112 | 5.05 | 97.0 | 415.0 | 75 | 4.28 | 82.0 | 301.0 | 48 | 3.67 | 233.0 | 1003.0 | 230 | 4.30 | 443.0 | 1963.0 | 527 | 4.43 |
NR | 3731 |
Username | chris.wege |
Einbaujahr der WP | 2022-03-31 |
PLZ des Wohnortes | 85462 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | IDM iPump ALM 2-8 |
modulierend | Ja |
Leistung (0/35) | 3.5 kW |
berechneter Primärenergiebedarf | 38.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 46 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 770 Watt DB |
elektr. Verbrauch HP gem./DB | 42 Watt |
elektr. Verbrauch WQ P gem./DB | 4 Watt |
Stromzähler | intern > erfasst: Kompressor |
WMZ | intern |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 1.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 2.5 |
Heizflaeche | 254 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | EFH Bj. 2022, FBH mit aktiver Kühlung, Keller, OG, EG mit 250m², keine ERR, hydr. und thermischer Abgleich, PV Anlage 11,25kWp mit Speicher 7,7kWh. kein Pufferbetrieb (Mischer voll auf) und Abgleich beider Heizkreispumpen auf gleichen Volumenstrom. |