Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
3748 | Luft/Wasser | Daikin Altherma 3 R ECH2O 504 | 5.4 | 2024 | 135 | 3 | 1586.3 | 6672.0 | 4.21 | 398.0 | 1486.0 | 3.73 | 221.0 | 980.0 | 4.43 | 227.0 | 968.0 | 4.26 | 148.0 | 635.0 | 4.29 | 51.0 | 182.0 | 3.57 | 42.0 | 171.0 | 4.07 | 36.0 | 115.0 | 3.19 | 27.0 | 114.0 | 4.22 | 51.3 | 205.0 | 4.00 | 136.0 | 669.0 | 4.92 | 249.0 | 1147.0 | 4.61 | 0 | 0 | ||||||||||||||||||||||||||
3748 | Luft/Wasser | Daikin Altherma 3 R ECH2O 504 | 5.4 | 2023 | 135 | 3 | 2138.1 | 7154.0 | 3.35 | 311.9 | 960.0 | 3.08 | 326.1 | 914.0 | 2.80 | 312.3 | 1061.0 | 3.40 | 221.7 | 742.0 | 3.35 | 91.8 | 267.0 | 2.91 | 33.6 | 102.0 | 3.04 | 36.2 | 115.0 | 3.18 | 37.5 | 109.0 | 2.91 | 38.5 | 112.0 | 2.91 | 116.5 | 357.0 | 3.06 | 274.0 | 964.0 | 3.52 | 338.0 | 1451.0 | 4.29 | |||||||||||||||||||||||||
3748 | Luft/Wasser | Daikin Altherma 3 R ECH2O 504 | 5.4 | 2022 | 135 | 791.8 | 2515.0 | 3.18 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 65.0 | 167.0 | 2.57 | 279.6 | 950.0 | 3.40 | 447.2 | 1398.0 | 3.13 |
NR | 3748 |
Username | ekim |
Einbaujahr der WP | 2022-09-01 |
PLZ des Wohnortes | 15741 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Daikin Altherma 3 R ECH2O 504 |
modulierend | Ja |
Leistung (0/35) | 5.4 kW |
berechneter Primärenergiebedarf | 26.8 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 40 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor |
WMZ | intern |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 10.5 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 2.0 |
Heizflaeche | 135 m² |
Lüftung | dezKWLWR |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | nein |
Bemerkungen | KFW 55 Neubau 2022 Seit 11/23 ohne ERR -> konstanter Voluemstrom >= 550 l/h |