Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
3755 | DV/Wasser | Heliotherm HP08E-M-BC | 8.0 | 2024 | 220 | 2 | 311.0 | 1496.0 | 229 | 4.81 | 311.0 | 1496.0 | 229 | 4.81 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
3755 | DV/Wasser | Heliotherm HP08E-M-BC | 8.0 | 2013 | 220 | 4 | 1373.0 | 4865.0 | 493 | 5.28 | 486.0 | 2523.0 | 259 | 5.19 | 435.0 | 2342.0 | 234 | 5.38 | 452.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
3755 | DV/Wasser | Heliotherm HP08E-M-BC | 8.0 | 2012 | 220 | 4 | 2654.0 | 13472.0 | 1370 | 5.08 | 485.0 | 2370.0 | 262 | 4.89 | 507.0 | 2555.0 | 275 | 5.04 | 290.0 | 1432.0 | 150 | 4.94 | 227.0 | 1105.0 | 114 | 4.87 | 56.0 | 259.0 | 25 | 4.63 | 46.0 | 209.0 | 18 | 4.54 | 39.0 | 188.0 | 17 | 4.82 | 35.0 | 173.0 | 14 | 4.94 | 35.0 | 175.0 | 15 | 5.00 | 176.0 | 953.0 | 80 | 5.41 | 297.0 | 1636.0 | 155 | 5.51 | 461.0 | 2417.0 | 245 | 5.24 | ||||||||||||
3755 | DV/Wasser | Heliotherm HP08E-M-BC | 8.0 | 2011 | 220 | 4 | 2954.0 | 13916.0 | 1608 | 4.71 | 324.0 | 1512.0 | 109 | 4.67 | 324.0 | 1512.0 | 190 | 4.67 | 324.0 | 1512.0 | 190 | 4.67 | 324.0 | 1512.0 | 190 | 4.67 | 324.0 | 1512.0 | 190 | 4.67 | 324.0 | 1512.0 | 190 | 4.67 | 41.0 | 172.0 | 18 | 4.20 | 41.0 | 172.0 | 18 | 4.20 | 41.0 | 172.0 | 18 | 4.20 | 151.0 | 769.0 | 76 | 5.09 | 323.0 | 1584.0 | 174 | 4.90 | 413.0 | 1975.0 | 245 | 4.78 | ||||||||||||
3755 | DV/Wasser | Heliotherm HP08E-M-BC | 8.0 | 2010 | 220 | 4 | 1269.0 | 6048.0 | 760 | 4.77 | 1269.0 | 6048.0 | 760 | 4.77 |
NR | 3755 |
Username | ersthausbauer |
Einbaujahr der WP | 2024-12-06 |
PLZ des Wohnortes | 39126 |
Bauart | DV/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Heliotherm HP08E-M-BC |
modulierend | Ja |
Leistung (0/35) | 8.0 kW |
berechneter Primärenergiebedarf | 37.2 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Flachkollektoren |
Tiefe | 1.2 m |
Fläche | 180 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1440 Watt DB |
elektr. Verbrauch HP gem./DB | 65 Watt |
elektr. Verbrauch WQ P gem./DB | 40 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 3.0 °C |
Heizung max. Vorlauf Temp. | 29.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 220 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | nein |
Bemerkungen | Haus aus 2010 mit DV Heliotherm Hp08 Web Oktober 2024 Verdichter Tot. Anlage alt 691 Anlage wurde im Dezember 2024 durch eine Neue Heliotherm DV WP ersetzt. HP08E-M-BC |