Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3835 | Luft/Wasser | IDM ALM 6-15 | 14.0 | 2025 | 260 | 4 | 2811.0 | 13602.0 | 1901 | 4.84 | 697.0 | 3450.0 | 572 | 4.95 | 610.0 | 2912.0 | 455 | 4.77 | 461.0 | 2283.0 | 342 | 4.95 | 270.0 | 1319.0 | 178 | 4.89 | 168.0 | 722.0 | 75 | 4.30 | 99.0 | 397.0 | 27 | 4.01 | 97.0 | 377.0 | 27 | 3.89 | 81.0 | 325.0 | 22 | 4.01 | 95.0 | 491.0 | 38 | 5.17 | 233.0 | 1326.0 | 165 | 5.69 | ||||||||||||||||||||
| 3835 | Luft/Wasser | IDM ALM 6-15 | 14.0 | 2024 | 260 | 4 | 3472.0 | 16874.0 | 2648 | 4.86 | 651.0 | 3100.0 | 542 | 4.76 | 347.0 | 1840.0 | 314 | 5.30 | 346.0 | 1770.0 | 291 | 5.12 | 295.0 | 1380.0 | 204 | 4.68 | 148.0 | 534.0 | 48 | 3.61 | 127.0 | 453.0 | 37 | 3.57 | 82.0 | 334.0 | 26 | 4.07 | 75.0 | 303.0 | 24 | 4.04 | 112.0 | 441.0 | 36 | 3.94 | 192.0 | 1029.0 | 149 | 5.36 | 434.0 | 2390.0 | 431 | 5.51 | 663.0 | 3300.0 | 546 | 4.98 | ||||||||||||
| 3835 | Luft/Wasser | IDM ALM 6-15 | 14.0 | 2023 | 260 | 4 | 1189.0 | 6591.0 | 1057 | 5.54 | 76.0 | 336.0 | 23 | 4.42 | 78.0 | 331.0 | 27 | 4.24 | 172.0 | 764.0 | 81 | 4.44 | 398.0 | 2580.0 | 411 | 6.48 | 465.0 | 2580.0 | 515 | 5.55 |
| NR | 3835 |
| Username | Pepe |
| Einbaujahr der WP | 2023-09-30 |
| PLZ des Wohnortes | 70563 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | IDM ALM 6-15 |
| modulierend | Ja |
| Leistung (0/35) | 14.0 kW |
| berechneter Primärenergiebedarf | 44.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 48 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | Radiatoren |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | intern > erfasst: |
| WMZ | intern |
| Mittlere Raumtemp. | 21.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 45.0 °C |
| Spreizung Heizkr. | 5.0 |
| Heizflaeche | 260 m² |
| Lüftung | Fenster |
| Personen | 4 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Baujahr 1958, saniert 2010 (Dach, Fassande, Fenster, Kellerdecke) PV 21,5 KWp, 17,5 KWh Speicher |