Verbrauchsdaten fuer Anlage Nr. 3866
| Jahr | Pers. | GESAMT | Jan | Feb | Mar | Apr | Mai | Jun | Jul | Aug | Sep | Okt | Nov | Dez | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | ||
| 2026 | 4 | 2411 | 7124 | 2.95 | 1104 | 3127 | 2.83 | 758 | 2290 | 3.02 | 549 | 1707 | 3.11 | |||||||||||||||||||||||||||
| 2025 | 4 | 5812 | 16866 | 2.90 | 1121 | 3073 | 2.74 | 1027 | 2857 | 2.78 | 813 | 2484 | 3.06 | 391 | 1217 | 3.11 | 183 | 528 | 2.89 | 116 | 347 | 2.99 | 89 | 247 | 2.78 | 82 | 212 | 2.59 | 174 | 462 | 2.66 | 313 | 888 | 2.84 | 581 | 1770 | 3.05 | 922 | 2781 | 3.02 |
| 2024 | 4 | 735 | 1979 | 2.69 | 735 | 1979 | 2.69 | |||||||||||||||||||||||||||||||||
Vollständige Anlagendetails
Allgemeine Daten
Anlagen Nr.
3866
Username
Ahrtal
Gebäude Daten
PLZ
53474
Heizfläche (m²)
163
Wärmeübertragung
Radiatoren
Raumtemperatur (°C)
20.0
Lüftung
Fenster
Endenergiebedarf (kWh/m²/anno)
130.0
berechnet nach Norm
Wärmepumpe Daten
Hersteller / Typ
Bosch Compress 5800i AW 10 OR-T
Bauart
Luft/Wasser
Heizleistung (kW) (0/35 2/35)
10.0
Betriebsart Mono/Bi/Tri-valent
Mono
Modulierend
Ja
Einbaudatum
2024-12-10
Wärmepumpe Leistungsaufnahme (W)
Umwälzpumpe Leistungsaufnahme (W)
Wärme Quelle & Senke
Quelle
Luft
Tiefe (m)
Fläche (m²)
max. Vorlauftemperatur (°C)
50.0
Spreizung Heizkreise (°K)
Quellenpumpe Leistungsaufnahme (W)
RGK Helfer
Nein
RGK Erfahrung
Warmwasser
über WP erzeugt
Ja
über WMZ erfasst
Ja
Temp (°C)
50
Legionellenschaltung
Nein
Zähler
Stromzähler
intern
Stromzähler erfasst
Kompressor,Steuerung,Pumpen
Wärmemengenzähler
intern
Informationen
Bemerkungen
Links