Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 4065 | Luft/Wasser | Nibe S2125-12 | 9.0 | 2026 | 235 | 3 | 1090.0 | 4641.0 | 4.26 | 1090.0 | 4641.0 | 4.26 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 4065 | Luft/Wasser | Nibe S2125-12 | 9.0 | 2025 | 235 | 3 | 5172.0 | 25780.0 | 4.98 | 1114.0 | 5006.0 | 4.49 | 820.0 | 3774.0 | 4.60 | 490.0 | 2639.0 | 5.39 | 267.0 | 1600.0 | 5.99 | 242.0 | 1327.0 | 5.48 | 64.0 | 359.0 | 5.61 | 58.0 | 304.0 | 5.24 | 68.0 | 391.0 | 5.75 | 147.0 | 966.0 | 6.57 | 341.0 | 1977.0 | 5.80 | 692.0 | 3299.0 | 4.77 | 869.0 | 4138.0 | 4.76 | |||||||||||||||||||||||||
| 4065 | Luft/Wasser | Nibe S2125-12 | 9.0 | 2024 | 235 | 3 | 3004.0 | 13024.0 | 4.34 | 212.0 | 1522.0 | 7.18 | 71.0 | 455.0 | 6.41 | 599.0 | 102.0 | 0.17 | 65.0 | 308.0 | 4.74 | 59.0 | 293.0 | 4.97 | 149.0 | 928.0 | 6.23 | 252.0 | 1753.0 | 6.96 | 624.0 | 3300.0 | 5.29 | 973.0 | 4363.0 | 4.48 |
| NR | 4065 |
| Username | Username1 |
| Einbaujahr der WP | 2024-03-11 |
| PLZ des Wohnortes | A-4663 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Nibe S2125-12 |
| modulierend | Ja |
| Leistung (0/35) | 9.0 kW |
| berechneter Primärenergiebedarf | 44.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 49 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 3 Watt DB |
| elektr. Verbrauch HP gem./DB | 55 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 23.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 31.0 °C |
| Spreizung Heizkr. | 4.0 |
| Heizflaeche | 235 m² |
| Lüftung | Fenster |
| Personen | 3 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Hanglage südliche Ausrichtung |