Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
409 | Luft/Wasser | Daikin Altherma | 11.2 | 2018 | 180 | 2 | 1631.0 | 6066.0 | 1300 | 3.72 | 486.0 | 1975.0 | 390 | 4.06 | 597.0 | 2070.0 | 437 | 3.47 | 548.0 | 2021.0 | 473 | 3.69 | ||||||||||||||||||||||||||||||||||||||||||||||||
409 | Luft/Wasser | Daikin Altherma | 11.2 | 2017 | 180 | 2 | 3022.0 | 11725.0 | 2364 | 3.88 | 690.0 | 2380.0 | 480 | 3.45 | 511.0 | 1933.0 | 450 | 3.78 | 318.0 | 1445.0 | 245 | 4.54 | 225.0 | 1042.0 | 203 | 4.63 | 53.0 | 100.0 | 16 | 1.89 | 50.0 | 100.0 | 18 | 2.00 | 50.0 | 100.0 | 17 | 2.00 | 46.0 | 76.0 | 15 | 1.65 | 55.0 | 104.0 | 18 | 1.89 | 178.0 | 890.0 | 242 | 5.00 | 328.0 | 1480.0 | 242 | 4.51 | 518.0 | 2075.0 | 418 | 4.01 | ||||||||||||
409 | Luft/Wasser | Daikin Altherma | 11.2 | 2016 | 180 | 2 | 2892.0 | 11076.0 | 2331 | 3.83 | 690.0 | 2461.0 | 490 | 3.57 | 450.0 | 1915.0 | 430 | 4.26 | 374.0 | 1630.0 | 360 | 4.36 | 146.0 | 580.0 | 150 | 3.97 | 50.0 | 95.0 | 20 | 1.90 | 50.0 | 95.0 | 21 | 1.90 | 50.0 | 100.0 | 22 | 2.00 | 50.0 | 100.0 | 21 | 2.00 | 40.0 | 60.0 | 12 | 1.50 | 142.0 | 615.0 | 115 | 4.33 | 404.0 | 1661.0 | 320 | 4.11 | 446.0 | 1764.0 | 370 | 3.96 | ||||||||||||
409 | Luft/Wasser | Daikin Altherma | 11.2 | 2015 | 180 | 2 | 2600.0 | 10444.0 | 2230 | 4.02 | 517.0 | 1960.0 | 432 | 3.79 | 495.0 | 2022.0 | 412 | 4.08 | 335.0 | 1528.0 | 340 | 4.56 | 184.0 | 770.0 | 170 | 4.18 | 49.0 | 80.0 | 21 | 1.63 | 53.0 | 100.0 | 20 | 1.89 | 50.0 | 100.0 | 22 | 2.00 | 50.0 | 100.0 | 23 | 2.00 | 50.0 | 100.0 | 18 | 2.00 | 190.0 | 888.0 | 167 | 4.67 | 287.0 | 1272.0 | 280 | 4.43 | 340.0 | 1524.0 | 325 | 4.48 | ||||||||||||
409 | Luft/Wasser | Daikin Altherma | 11.2 | 2014 | 180 | 2 | 2661.0 | 10492.0 | 2148 | 3.94 | 648.0 | 2398.0 | 515 | 3.70 | 365.0 | 1647.0 | 311 | 4.51 | 262.0 | 1257.0 | 300 | 4.80 | 141.0 | 693.0 | 104 | 4.91 | 69.0 | 130.0 | 23 | 1.88 | 51.0 | 105.0 | 20 | 2.06 | 55.0 | 115.0 | 20 | 2.09 | 52.0 | 95.0 | 21 | 1.83 | 55.0 | 115.0 | 20 | 2.09 | 118.0 | 488.0 | 93 | 4.14 | 284.0 | 1272.0 | 271 | 4.48 | 561.0 | 2177.0 | 450 | 3.88 | ||||||||||||
409 | Luft/Wasser | Daikin Altherma | 11.2 | 2013 | 180 | 2 | 4073.0 | 15344.0 | 3220 | 3.77 | 817.0 | 3043.0 | 566 | 3.72 | 785.0 | 2912.0 | 606 | 3.71 | 910.0 | 3218.0 | 680 | 3.54 | 291.0 | 1119.0 | 220 | 3.85 | 40.0 | 45.0 | 11 | 1.13 | 51.0 | 107.0 | 20 | 2.10 | 50.0 | 101.0 | 20 | 2.02 | 51.0 | 102.0 | 20 | 2.00 | 56.0 | 110.0 | 20 | 1.96 | 203.0 | 1004.0 | 284 | 4.95 | 359.0 | 1621.0 | 345 | 4.52 | 460.0 | 1962.0 | 428 | 4.27 | ||||||||||||
409 | Luft/Wasser | Daikin Altherma | 11.2 | 2012 | 180 | 2 | 4132.0 | 16522.0 | 2619 | 4.00 | 748.0 | 3094.0 | 575 | 4.14 | 979.0 | 3435.0 | 580 | 3.51 | 384.0 | 1843.0 | 90 | 4.80 | 287.0 | 1340.0 | 60 | 4.67 | 56.0 | 105.0 | 20 | 1.88 | 52.0 | 115.0 | 19 | 2.21 | 56.0 | 118.0 | 22 | 2.11 | 49.0 | 99.0 | 19 | 2.02 | 53.0 | 113.0 | 22 | 2.13 | 250.0 | 1205.0 | 225 | 4.82 | 434.0 | 2060.0 | 414 | 4.75 | 784.0 | 2995.0 | 573 | 3.82 | ||||||||||||
409 | Luft/Wasser | Daikin Altherma | 11.2 | 2011 | 180 | 2 | 3442.2 | 12451.0 | 2849 | 3.62 | 761.0 | 2652.0 | 699 | 3.48 | 677.0 | 2167.0 | 537 | 3.20 | 390.0 | 1336.0 | 510 | 3.43 | 71.2 | 168.0 | 23 | 2.36 | 53.0 | 98.0 | 10 | 1.85 | 49.0 | 84.0 | 9 | 1.71 | 53.0 | 86.0 | 12 | 1.62 | 52.0 | 98.0 | 12 | 1.88 | 51.0 | 86.0 | 11 | 1.69 | 245.0 | 1091.0 | 186 | 4.45 | 477.0 | 1970.0 | 370 | 4.13 | 563.0 | 2615.0 | 470 | 4.64 | ||||||||||||
409 | Luft/Wasser | Daikin Altherma | 11.2 | 2010 | 180 | 2 | 2306.0 | 8460.0 | 2130 | 3.67 | 615.0 | 2615.0 | 600 | 4.25 | 666.0 | 2737.0 | 680 | 4.11 | 1025.0 | 3108.0 | 850 | 3.03 |
NR | 409 |
Username | kris |
Einbaujahr der WP | 2010-08-01 |
PLZ des Wohnortes | 16540 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Daikin Altherma |
modulierend | |
Leistung (0/35) | 11.2 kW |
berechneter Primärenergiebedarf | 35.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 42 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2240 Watt DB |
elektr. Verbrauch HP gem./DB | 25 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 33.0 °C |
Spreizung Heizkr. | 4.0 |
Heizflaeche | 180 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | ACHTUNG! - Heizungsanlage in 08/2018 gegen SWWP getauscht, diese ist nun unter User "Randberliner" zu finden - Altbau Ende 2013 bis Mitte 2014 gedämmt, Verbrauch incl. UWP LAING E6 auf Stufe 3, ca. 1000l/h, Heizkurve +14: 26°C VL, -14: 33°C VL |