Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
465 | Luft/Wasser | Stiebel-Eltron WPL 13E | 8.0 | 2016 | 190 | 4 | 658.2 | 2242.0 | 3.41 | 658.2 | 2242.0 | 3.41 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
465 | Luft/Wasser | Stiebel-Eltron WPL 13E | 8.0 | 2015 | 190 | 5 | 3630.4 | 13741.0 | 3.78 | 694.2 | 2345.0 | 3.38 | 539.0 | 1886.0 | 3.50 | 434.6 | 1615.0 | 3.72 | 258.7 | 1042.0 | 4.03 | 258.7 | 1042.0 | 4.03 | 1017.2 | 4085.0 | 4.02 | 428.0 | 1726.0 | 4.03 | ||||||||||||||||||||||||||||||||||||||||
465 | Luft/Wasser | Stiebel-Eltron WPL 13E | 8.0 | 2014 | 190 | 5 | 3272.8 | 12641.0 | 3.86 | 625.5 | 2198.0 | 3.51 | 436.2 | 1666.0 | 3.82 | 361.7 | 1429.0 | 3.95 | 206.3 | 853.0 | 4.13 | 186.9 | 870.0 | 4.65 | 88.0 | 409.0 | 4.65 | 34.9 | 144.0 | 4.13 | 71.8 | 335.0 | 4.67 | 107.1 | 464.0 | 4.33 | 186.9 | 787.0 | 4.21 | 366.0 | 1384.0 | 3.78 | 601.5 | 2102.0 | 3.49 | |||||||||||||||||||||||||
465 | Luft/Wasser | Stiebel-Eltron WPL 13E | 8.0 | 2013 | 190 | 4 | 3999.9 | 14631.0 | 3.66 | 729.5 | 2481.0 | 3.40 | 658.6 | 2217.0 | 3.37 | 685.0 | 2345.0 | 3.42 | 318.9 | 1251.0 | 3.92 | 177.2 | 783.0 | 4.42 | 65.8 | 304.0 | 4.62 | 15.0 | 85.0 | 5.67 | 18.8 | 84.0 | 4.47 | 103.4 | 427.0 | 4.13 | 219.2 | 932.0 | 4.25 | 512.0 | 1871.0 | 3.65 | 496.5 | 1851.0 | 3.73 | |||||||||||||||||||||||||
465 | Luft/Wasser | Stiebel-Eltron WPL 13E | 8.0 | 2012 | 190 | 4 | 3369.9 | 12367.0 | 3.67 | 548.0 | 1945.0 | 3.55 | 780.1 | 2325.0 | 2.98 | 276.7 | 1212.0 | 4.38 | 248.0 | 1036.0 | 4.18 | 61.4 | 271.0 | 4.41 | 68.2 | 314.0 | 4.60 | 21.5 | 110.0 | 5.12 | 11.6 | 57.0 | 4.91 | 64.3 | 295.0 | 4.59 | 222.3 | 904.0 | 4.07 | 422.2 | 1639.0 | 3.88 | 645.6 | 2259.0 | 3.50 | |||||||||||||||||||||||||
465 | Luft/Wasser | Stiebel-Eltron WPL 13E | 8.0 | 2011 | 190 | 4 | 2871.0 | 10477.0 | 3.65 | 638.0 | 2160.0 | 3.39 | 546.0 | 1857.0 | 3.40 | 344.0 | 1284.0 | 3.73 | 126.0 | 518.0 | 4.11 | 65.0 | 269.0 | 4.14 | 33.0 | 130.0 | 3.94 | 44.0 | 172.0 | 3.91 | 15.0 | 60.0 | 4.00 | 27.0 | 114.0 | 4.22 | 152.0 | 625.0 | 4.11 | 371.0 | 1381.0 | 3.72 | 510.0 | 1907.0 | 3.74 | |||||||||||||||||||||||||
465 | Luft/Wasser | Stiebel-Eltron WPL 13E | 8.0 | 2010 | 190 | 4 | 1597.0 | 5269.0 | 3.30 | 319.0 | 1178.0 | 3.69 | 427.0 | 1491.0 | 3.49 | 851.0 | 2600.0 | 3.06 |
NR | 465 |
Username | fengel |
Einbaujahr der WP | 2010-07-01 |
PLZ des Wohnortes | 37085 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Stiebel-Eltron WPL 13E |
modulierend | |
Leistung (0/35) | 8.0 kW |
berechneter Primärenergiebedarf | 62.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2400 Watt DB |
elektr. Verbrauch HP gem./DB | 63 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 190 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Pufferspeicher 400L WW-Speicher 400L mit Solar Unterstützung Einzelraumreglung mit Fensterkontakt-Abschaltung Aufstellung im Haus BJ 1966, saniert 2010 (Fassadendämmung 14cm, Fenster 3-fach Verglasung, Geschoßdecke gedämmt, Kaltdach) |