Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
47 | Sole/Wasser | Waterkotte | 9.4 | 2014 | 209 | 2 | 3300.0 | 14260.0 | 1412 | 4.32 | 971.0 | 4061.0 | 441 | 4.18 | 724.0 | 3143.0 | 338 | 4.34 | 595.0 | 2562.0 | 268 | 4.31 | 337.0 | 1543.0 | 154 | 4.58 | 307.0 | 1366.0 | 134 | 4.45 | 123.0 | 539.0 | 51 | 4.38 | 71.0 | 270.0 | 26 | 3.80 | 172.0 | 776.0 | 4.51 | |||||||||||||||||||||||||||||
47 | Sole/Wasser | Waterkotte | 9.4 | 2013 | 209 | 3 | 7111.0 | 30383.0 | 3269 | 4.27 | 1185.0 | 4998.0 | 557 | 4.22 | 1102.0 | 4581.0 | 518 | 4.16 | 1131.0 | 4703.0 | 531 | 4.16 | 584.0 | 2495.0 | 271 | 4.27 | 363.0 | 1635.0 | 166 | 4.50 | 170.0 | 756.0 | 74 | 4.45 | 104.0 | 413.0 | 39 | 3.97 | 99.0 | 393.0 | 37 | 3.97 | 254.0 | 1196.0 | 114 | 4.71 | 403.0 | 1806.0 | 173 | 4.48 | 790.0 | 3517.0 | 369 | 4.45 | 926.0 | 3890.0 | 420 | 4.20 | ||||||||||||
47 | Sole/Wasser | Waterkotte | 9.4 | 2012 | 209 | 3 | 6551.0 | 28679.0 | 2938 | 4.38 | 1117.0 | 4638.0 | 509 | 4.15 | 1093.0 | 4622.0 | 423 | 4.23 | 643.0 | 2832.0 | 299 | 4.40 | 582.0 | 2584.0 | 270 | 4.44 | 246.0 | 1104.0 | 110 | 4.49 | 203.0 | 935.0 | 90 | 4.61 | 124.0 | 547.0 | 52 | 4.41 | 86.0 | 359.0 | 34 | 4.17 | 244.0 | 1172.0 | 109 | 4.80 | 477.0 | 2229.0 | 230 | 4.67 | 736.0 | 3331.0 | 343 | 4.53 | 1000.0 | 4326.0 | 469 | 4.33 | ||||||||||||
47 | Sole/Wasser | Waterkotte | 9.4 | 2011 | 209 | 3 | 6404.0 | 24469.0 | 2706 | 3.82 | 1093.0 | 4450.0 | 482 | 4.07 | 1014.0 | 4003.0 | 448 | 3.95 | 807.0 | 3155.0 | 354 | 3.91 | 406.0 | 1481.0 | 170 | 3.65 | 296.0 | 941.0 | 107 | 3.18 | 246.0 | 627.0 | 75 | 2.55 | 290.0 | 787.0 | 97 | 2.71 | 222.0 | 536.0 | 65 | 2.41 | 251.0 | 665.0 | 83 | 2.65 | 259.0 | 1175.0 | 132 | 4.54 | 568.0 | 2546.0 | 255 | 4.48 | 952.0 | 4103.0 | 438 | 4.31 | ||||||||||||
47 | Sole/Wasser | Waterkotte | 9.4 | 2010 | 209 | 4 | 7666.0 | 31099.0 | 3104 | 4.06 | 1378.0 | 5530.0 | 572 | 4.01 | 1130.0 | 4522.0 | 474 | 4.00 | 956.0 | 3888.0 | 397 | 4.07 | 588.0 | 2430.0 | 234 | 4.13 | 465.0 | 1955.0 | 185 | 4.20 | 156.0 | 460.0 | 41 | 2.95 | 137.0 | 302.0 | 25 | 2.20 | 174.0 | 453.0 | 40 | 2.60 | 244.0 | 991.0 | 86 | 4.06 | 430.0 | 1997.0 | 181 | 4.64 | 694.0 | 3116.0 | 292 | 4.49 | 1314.0 | 5455.0 | 577 | 4.15 | ||||||||||||
47 | Sole/Wasser | Waterkotte | 9.4 | 2009 | 209 | 4 | 6454.0 | 27463.0 | 2615 | 4.26 | 1202.0 | 4953.0 | 501 | 4.12 | 999.0 | 4146.0 | 417 | 4.15 | 888.0 | 3793.0 | 371 | 4.27 | 324.0 | 1456.0 | 129 | 4.49 | 282.0 | 1285.0 | 110 | 4.56 | 191.0 | 815.0 | 68 | 4.27 | 86.0 | 261.0 | 21 | 3.03 | 93.0 | 311.0 | 25 | 3.34 | 134.0 | 544.0 | 44 | 4.06 | 555.0 | 2539.0 | 222 | 4.57 | 616.0 | 2793.0 | 252 | 4.53 | 1084.0 | 4567.0 | 455 | 4.21 | ||||||||||||
47 | Sole/Wasser | Waterkotte | 9.4 | 2008 | 209 | 4 | 2699.0 | 11756.0 | 1052 | 4.36 | 127.0 | 440.0 | 35 | 3.46 | 297.0 | 1287.0 | 103 | 4.33 | 485.0 | 2254.0 | 189 | 4.65 | 729.0 | 3292.0 | 295 | 4.52 | 1061.0 | 4483.0 | 430 | 4.23 |
NR | 47 |
Username | RalliDWP |
Einbaujahr der WP | 2008-08-08 |
PLZ des Wohnortes | 59609 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Waterkotte |
modulierend | |
Leistung (0/35) | 9.4 kW |
berechneter Primärenergiebedarf | 8.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 46 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 75.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 2100 Watt DB |
elektr. Verbrauch HP gem./DB | 120 Watt |
elektr. Verbrauch WQ P gem./DB | 120 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 20.0 °C |
Mittlere Wärmequellentemperatur | 4.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 4.0 |
Heizflaeche | 209 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |