Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
482 | Sole/Wasser | Vaillant GeoThem VWS 61/2 | 5.9 | 2014 | 166 | 3 | 873.5 | 2453.5 | 2.81 | 873.5 | 2453.5 | 2.81 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
482 | Sole/Wasser | Vaillant GeoThem VWS 61/2 | 5.9 | 2013 | 166 | 3 | 4223.8 | 14952.8 | 3.54 | 663.3 | 2372.3 | 3.58 | 594.6 | 2101.6 | 3.53 | 641.9 | 2205.9 | 3.44 | 407.0 | 1368.0 | 3.36 | 213.4 | 717.4 | 3.36 | 107.4 | 329.4 | 3.07 | 92.0 | 292.0 | 3.17 | 78.0 | 248.0 | 3.18 | 193.4 | 719.4 | 3.72 | 280.6 | 1046.6 | 3.73 | 427.4 | 1648.4 | 3.86 | 524.8 | 1903.8 | 3.63 | |||||||||||||||||||||||||
482 | Sole/Wasser | Vaillant GeoThem VWS 61/2 | 5.9 | 2012 | 166 | 3 | 4150.6 | 14898.3 | 3.59 | 611.0 | 2258.0 | 3.70 | 711.0 | 2438.0 | 3.43 | 503.0 | 1736.0 | 3.45 | 395.0 | 1370.0 | 3.47 | 173.0 | 570.7 | 3.30 | 126.0 | 425.0 | 3.37 | 62.0 | 223.0 | 3.60 | 59.0 | 217.0 | 3.68 | 147.6 | 543.6 | 3.68 | 298.0 | 1153.0 | 3.87 | 418.0 | 1593.0 | 3.81 | 647.0 | 2371.0 | 3.66 | |||||||||||||||||||||||||
482 | Sole/Wasser | Vaillant GeoThem VWS 61/2 | 5.9 | 2011 | 166 | 2 | 4108.6 | 15395.0 | 3.75 | 733.8 | 2742.0 | 3.74 | 701.0 | 2536.0 | 3.62 | 617.0 | 2188.0 | 3.55 | 285.0 | 1045.0 | 3.67 | 194.0 | 712.0 | 3.67 | 97.8 | 346.0 | 3.54 | 90.0 | 329.0 | 3.66 | 70.0 | 248.0 | 3.54 | 136.0 | 538.0 | 3.96 | 267.0 | 1091.0 | 4.09 | 397.5 | 1623.5 | 4.08 | 519.5 | 1996.5 | 3.84 | |||||||||||||||||||||||||
482 | Sole/Wasser | Vaillant GeoThem VWS 61/2 | 5.9 | 2010 | 166 | 2 | 1336.0 | 498.0 | 838.0 |
NR | 482 |
Username | unknown1 |
Einbaujahr der WP | 2010-10-18 |
PLZ des Wohnortes | |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Vaillant GeoThem VWS 61/2 |
modulierend | |
Leistung (0/35) | 5.9 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 59 °C |
WW Legionellenschaltung | Ja |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Flachkollektoren |
Tiefe | 1.4 m |
Fläche | 350 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 8.0 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 3.0 |
Heizflaeche | 166 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |