Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
516 | Luft/Wasser | Alpha Innotec LWA 90 A/RX | 9.4 | 2015 | 210 | 4 | 1648.0 | 863.0 | 785.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
516 | Luft/Wasser | Alpha Innotec LWA 90 A/RX | 9.4 | 2014 | 210 | 4 | 5388.0 | 902.0 | 694.0 | 600.0 | 315.0 | 284.0 | 171.0 | 165.0 | 183.0 | 177.0 | 315.0 | 570.0 | 1012.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
516 | Luft/Wasser | Alpha Innotec LWA 90 A/RX | 9.4 | 2013 | 210 | 3 | 7229.0 | 1135.0 | 1071.0 | 1006.0 | 499.0 | 332.0 | 330.0 | 344.0 | 230.0 | 285.0 | 338.0 | 758.0 | 901.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
516 | Luft/Wasser | Alpha Innotec LWA 90 A/RX | 9.4 | 2012 | 210 | 2 | 6672.0 | 1041.0 | 1412.0 | 539.0 | 457.0 | 226.0 | 192.0 | 162.0 | 245.0 | 393.0 | 469.0 | 644.0 | 892.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
516 | Luft/Wasser | Alpha Innotec LWA 90 A/RX | 9.4 | 2011 | 210 | 2 | 5992.0 | 1116.0 | 856.0 | 723.0 | 306.0 | 254.0 | 190.0 | 206.0 | 187.0 | 222.0 | 464.0 | 607.0 | 861.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
516 | Luft/Wasser | Alpha Innotec LWA 90 A/RX | 9.4 | 2010 | 210 | 2 | 4415.0 | 653.0 | 940.0 | 916.0 | 1906.0 |
NR | 516 |
Username | Joef |
Einbaujahr der WP | 0000-00-00 |
PLZ des Wohnortes | 58706 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Alpha Innotec LWA 90 A/RX |
modulierend | |
Leistung (0/35) | 9.4 kW |
berechneter Primärenergiebedarf | 74.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 46 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 0.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 210 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |