Verbrauchsdaten fuer Anlage Nr. 52
| Jahr | Pers. | GESAMT | Jan | Feb | Mar | Apr | Mai | Jun | Jul | Aug | Sep | Okt | Nov | Dez | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | ||
| 2017 | 2 | 7629 | 21900 | 2.87 | 2858 | 7970 | 2.79 | 2120 | 5880 | 2.77 | 1592 | 4860 | 3.05 | 708 | 2170 | 3.06 | 351 | 1020 | 2.91 | |||||||||||||||||||||
| 2016 | 2 | 8961 | 25980 | 2.90 | 1537 | 4260 | 2.77 | 1113 | 3150 | 2.83 | 1186 | 3350 | 2.82 | 684 | 1910 | 2.79 | 320 | 890 | 2.78 | 89 | 230 | 2.58 | 64 | 190 | 2.97 | 64 | 190 | 2.97 | 81 | 260 | 3.21 | 573 | 1990 | 3.47 | 999 | 3230 | 3.23 | 2251 | 6330 | 2.81 |
| 2015 | 2 | 7875 | 22630 | 2.87 | 1342 | 3910 | 2.91 | 1266 | 3560 | 2.81 | 1008 | 2900 | 2.88 | 651 | 1850 | 2.84 | 298 | 810 | 2.72 | 166 | 440 | 2.65 | 110 | 280 | 2.55 | 85 | 230 | 2.71 | 225 | 620 | 2.76 | 730 | 2150 | 2.95 | 894 | 2610 | 2.92 | 1100 | 3270 | 2.97 |
| 2014 | 2 | 7620 | 22750 | 2.99 | 1252 | 4280 | 3.42 | 1130 | 3220 | 2.85 | 872 | 2510 | 2.88 | 515 | 1610 | 3.13 | 379 | 1160 | 3.06 | 173 | 490 | 2.83 | 102 | 300 | 2.94 | 149 | 380 | 2.55 | 269 | 780 | 2.90 | 484 | 1450 | 3.00 | 883 | 2590 | 2.93 | 1412 | 3980 | 2.82 |
| 2013 | 2 | 9829 | 27620 | 2.81 | 1564 | 4430 | 2.83 | 1435 | 4200 | 2.93 | 1615 | 4420 | 2.74 | 830 | 2380 | 2.87 | 371 | 1130 | 3.05 | 218 | 640 | 2.94 | 121 | 330 | 2.73 | 120 | 330 | 2.75 | 366 | 1130 | 3.09 | 564 | 1750 | 3.10 | 1007 | 3030 | 3.01 | 1618 | 3850 | 2.38 |
| 2012 | 2 | 9237 | 26450 | 2.86 | 1559 | 4410 | 2.83 | 1823 | 5020 | 2.75 | 978 | 2820 | 2.88 | 776 | 2290 | 2.95 | 276 | 760 | 2.75 | 235 | 650 | 2.77 | 124 | 340 | 2.74 | 108 | 290 | 2.69 | 243 | 690 | 2.84 | 591 | 1820 | 3.08 | 1008 | 3040 | 3.02 | 1516 | 4320 | 2.85 |
| 2011 | 2 | 9288 | 26320 | 2.83 | 1656 | 4540 | 2.74 | 1667 | 4450 | 2.67 | 1208 | 3470 | 2.87 | 544 | 1600 | 2.94 | 317 | 910 | 2.87 | 163 | 440 | 2.70 | 174 | 470 | 2.70 | 132 | 360 | 2.73 | 261 | 760 | 2.91 | 673 | 2060 | 3.06 | 1129 | 3310 | 2.93 | 1364 | 3950 | 2.90 |
| 2010 | 2 | 11153 | 31902 | 2.86 | 1964 | 5391 | 2.74 | 1563 | 4341 | 2.78 | 1271 | 3634 | 2.86 | 708 | 2129 | 3.01 | 537 | 1687 | 3.14 | 222 | 653 | 2.94 | 96 | 266 | 2.77 | 177 | 524 | 2.96 | 474 | 1434 | 3.03 | 900 | 2703 | 3.00 | 1165 | 3400 | 2.92 | 2076 | 5740 | 2.76 |
| 2009 | 2 | 9044 | 17606 | 1.95 | 1811 | 1446 | 1179 | 3761 | 3.19 | 444 | 1369 | 3.08 | 279 | 864 | 3.10 | 264 | 814 | 3.08 | 102 | 306 | 3.00 | 97 | 267 | 2.75 | 222 | 684 | 3.08 | 771 | 2337 | 3.03 | 978 | 3040 | 3.11 | 1451 | 4164 | 2.87 | ||||
| 2008 | 2 | 5458 | 0 | 991 | 687 | 240 | 100 | 76 | 82 | 324 | 619 | 874 | 1465 | |||||||||||||||||||||||||||
Vollständige Anlagendetails
Allgemeine Daten
Anlagen Nr.
52
Username
Steffen.09
Gebäude Daten
PLZ
01968
Heizfläche (m²)
115
Wärmeübertragung
FBH
Raumtemperatur (°C)
23.0
Lüftung
dezKWLWR
Endenergiebedarf (kWh/m²/anno)
50.0
berechnet nach Norm
Wärmepumpe Daten
Hersteller / Typ
Viessmann Vitocal 300 bw226
Bauart
Sole/Wasser
Heizleistung (kW) (0/35 2/35)
28.0
Betriebsart Mono/Bi/Tri-valent
Bi
Modulierend
Einbaudatum
2008-03-15
Wärmepumpe Leistungsaufnahme (W)
6100 DB
Umwälzpumpe Leistungsaufnahme (W)
400 DB
Wärme Quelle & Senke
Quelle
sonstige
Tiefe (m)
50.0
Fläche (m²)
max. Vorlauftemperatur (°C)
48.0
Spreizung Heizkreise (°K)
Quellenpumpe Leistungsaufnahme (W)
400 DB
RGK Helfer
Nein
RGK Erfahrung
Warmwasser
über WP erzeugt
Ja
über WMZ erfasst
Ja
Temp (°C)
Legionellenschaltung
Zähler
Stromzähler
Stromzähler erfasst
Wärmemengenzähler
Informationen
Bemerkungen
Teilsaniertes 4-Familienhaus (Bj ca.1910, 106m NN, 2 Vollgeschosse, ber. Wärmebedarf 50 kW mit +2 WE Dachausbau). Derzeit 1 WE beheizt, daher 115 m² FBH mit 400l Puffer- und 390l WW-Speicher, bei Vollausbau 800/780 Liter geplant.
12 Bohrungen Doppel-U zw. 30 und 45 Meter tief, Abstandshalter, Bentonit, Schacht mit Soleverteiler. Abstand der Bohrungen untereinander 5 m. Soleseitig wird bei Vollausbau mit zweiter Sole-WP per Kugelhahn auf 2x6 Bohrlöcher getrennt, deshalb auch 2x Solepumpe WILO TOP S30/10 im Einsatz. WW und FBH ebenfalls WILO TOP S30/10. Heizstab für WW ist vorhanden. Verbrauchsdaten beziehen sich auf WP und Solepumpen. EVU-Sperrzeit z.Z. 2x am Tag je 1,5 Stunden.
Ab 12/2016 werden 2 weitere WE provisorisch mitgeheizt.
Links