Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
537 | Luft/Wasser | Wolf BWL08A | 8.1 | 2014 | 160 | 682.0 | * | 210.0 | 472.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
537 | Luft/Wasser | Wolf BWL08A | 8.1 | 2012 | 160 | 3 | 2290.0 | * | 759 | 140.0 | 48 | 85.0 | 23 | 306.0 | 105 | 140.0 | 47 | 78.0 | 27 | 1.0 | 1 | 1.0 | 1 | 1.0 | 1 | 81.0 | 26 | 331.0 | 106 | 482.0 | 157 | 644.0 | 217 | |||||||||||||||||||||||||||||||||||||
537 | Luft/Wasser | Wolf BWL08A | 8.1 | 2011 | 160 | 3 | 2552.0 | * | 1027 | 706.0 | 229 | 233.0 | 69 | 291.0 | 149 | 94.0 | 34 | 1.0 | 1 | 1.0 | 1 | 1.0 | 1 | 133.0 | 32 | 70.0 | 21 | 365.0 | 127 | 635.0 | 192 | 22.0 | 171 | |||||||||||||||||||||||||||||||||||||
537 | Luft/Wasser | Wolf BWL08A | 8.1 | 2010 | 160 | 3 | 3000.0 | * | 1029 | 421.0 | 144 | 404.0 | 129 | 396.0 | 136 | 248.0 | 94 | 196.0 | 62 | 59.0 | 18 | 1.0 | 1 | 34.0 | 10 | 100.0 | 30 | 333.0 | 120 | 534.0 | 187 | 274.0 | 98 | |||||||||||||||||||||||||||||||||||||
537 | Luft/Wasser | Wolf BWL08A | 8.1 | 2009 | 160 | 3 | 2944.0 | * | 1018 | 321.0 | 106 | 504.0 | 171 | 449.0 | 185 | 40.0 | 12 | 1.0 | 1 | 1.0 | 1 | 1.0 | 1 | 32.0 | 10 | 53.0 | 19 | 475.0 | 148 | 560.0 | 190 | 507.0 | 174 |
NR | 537 |
Username | frel24 |
Einbaujahr der WP | 2008-08-01 |
PLZ des Wohnortes | A-4240 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Wolf BWL08A |
modulierend | |
Leistung (0/35) | 8.1 kW |
berechneter Primärenergiebedarf | 61.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 47 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 160 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Niedrigenergiehaus, erbaut 2007, 25cm Ziegel + 16 cm Volwärmeschutz. In den kältemonaten wird mit Holz dazu geheitzt |