Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
539 | Luft/Wasser | Vaillant Geotherm VWL91 | 10.3 | 2023 | 160 | 4 | 3135.0 | 7732.0* | 1351 | 2.74 | 876.0 | 2033.0 | 212 | 2.64 | 749.0 | 1705.0 | 175 | 2.65 | 703.0 | 1692.0 | 171 | 2.81 | 497.0 | 1182.0 | 113 | 2.94 | 310.0 | 680 | ||||||||||||||||||||||||||||||||||||||||||
539 | Luft/Wasser | Vaillant Geotherm VWL91 | 10.3 | 2022 | 160 | 4 | 5696.0 | 14719.0* | 1272 | 2.58 | 926.0 | 1216.0 | 234 | 1.62 | 926.0 | 1216.0 | 189 | 1.62 | 586.0 | 1330.0 | 145 | 2.75 | 499.0 | 1330.0 | 114 | 3.23 | 247.0 | 541.0 | 45 | 3.32 | 179.0 | 386.0 | 30 | 3.72 | 127.0 | 269.0 | 21 | 4.32 | 97.0 | 216.0 | 26 | 5.11 | 189.0 | 441.0 | 29 | 3.81 | 497.0 | 1100.0 | 106 | 2.78 | 510.0 | 1260.0 | 107 | 3.02 | 913.0 | 2054.0 | 226 | 2.56 | ||||||||||||
539 | Luft/Wasser | Vaillant Geotherm VWL91 | 10.3 | 2021 | 160 | 4 | 6643.0 | * | 1608 | 1017.0 | 264 | 878.0 | 230 | 1016.0 | 254 | 378.0 | 89 | 532.0 | 126 | 155.0 | 27 | 160.0 | 28 | 404.0 | 91 | 404.0 | 91 | 404.0 | 91 | 404.0 | 91 | 891.0 | 226 | |||||||||||||||||||||||||||||||||||||
539 | Luft/Wasser | Vaillant Geotherm VWL91 | 10.3 | 2020 | 160 | 4 | 5994.0 | 16288.0* | 1313 | 2.72 | 997.0 | 1891.0 | 224 | 2.18 | 997.0 | 1891.0 | 224 | 2.18 | 588.0 | 1048.0 | 127 | 2.26 | 588.0 | 1048.0 | 127 | 2.26 | 281.0 | 1048.0 | 28 | 4.73 | 149.0 | 65.0 | 28 | 2.32 | 149.0 | 65.0 | 28 | 2.32 | 275.0 | 109.0 | 28 | 1.41 | 275.0 | 510.0 | 46 | 2.87 | 275.0 | 1751.0 | 99 | 7.39 | 710.0 | 1751.0 | 177 | 2.86 | 710.0 | 1751.0 | 177 | 2.86 | ||||||||||||
539 | Luft/Wasser | Vaillant Geotherm VWL91 | 10.3 | 2011 | 160 | 4 | 2576.0 | 8098.0* | 698 | 3.14 | 761.0 | 1816.0 | 263 | 2.75 | 612.0 | 1537.0 | 164 | 2.97 | 532.0 | 1307.0 | 137 | 2.98 | 227.0 | 523.0 | 50 | 3.54 | 177.0 | 380.0 | 35 | 3.73 | 140.0 | 308.0 | 26 | 4.20 | 127.0 | 267.0 | 23 | 4.31 | ||||||||||||||||||||||||||||||||
539 | Luft/Wasser | Vaillant Geotherm VWL91 | 10.3 | 2010 | 160 | 4 | 5915.0 | 17530.0* | 1617 | 2.96 | 1001.0 | 2202.0 | 419 | 2.48 | 854.0 | 1979.0 | 233 | 2.65 | 710.0 | 1785.0 | 183 | 2.91 | 416.0 | 1062.0 | 107 | 3.23 | 416.0 | 1082.0 | 102 | 3.27 | 167.0 | 392.0 | 34 | 4.02 | 78.0 | 182.0 | 13 | 5.92 | 78.0 | 182.0 | 13 | 5.92 | 131.0 | 319.0 | 124 | 4.57 | 478.0 | 1311.0 | 147 | 3.33 | 545.0 | 1357.0 | 242 | 3.00 | 1041.0 | 2317.0 | 2.49 | |||||||||||||
539 | Luft/Wasser | Vaillant Geotherm VWL91 | 10.3 | 2009 | 160 | 4 | 2697.0 | 8860.0* | 526 | 3.29 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 350.0 | 876.0 | 78 | 3.30 | 172.0 | 373.0 | 33 | 3.80 | 128.0 | 293.0 | 25 | 4.48 | 120.0 | 272.0 | 22 | 4.60 | 131.0 | 289.0 | 28 | 4.34 | 443.0 | 613.0 | 113 | 2.02 | 451.0 | 1774.0 | 118 | 4.55 | 902.0 | 2130.0 | 109 | 2.67 |
NR | 539 |
Username | 1701 |
Einbaujahr der WP | 2009-02-25 |
PLZ des Wohnortes | 44795 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Vaillant Geotherm VWL91 |
modulierend | |
Leistung (0/35) | 10.3 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 39 °C |
WW Legionellenschaltung | wöchentlich |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 10.0 °C |
Heizung max. Vorlauf Temp. | 34.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 160 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Kein WMZ eingebaut (soll noch geschehen). Wärmezahlen aus der WP-Anzeige. |