| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 55 | Luft/Wasser | Stiebel Eltron WPL 18 | 11.6 | 2011 | 179 | 3 | 2255.0 | 417 | 322.0 | 68 | 332.0 | 70 | 352.0 | 74 | 244.0 | 43 | 140.0 | 21 | 144.0 | 20 | 114.0 | 17 | 68.0 | 12 | 109.0 | 23 | 100.0 | 13 | 156.0 | 26 | 174.0 | 30 | ||||||||||||||||||||||||||||||||||||||
| 55 | Luft/Wasser | Stiebel Eltron WPL 18 | 11.6 | 2010 | 179 | 4 | 2667.0 | 528 | 458.0 | 110 | 328.0 | 69 | 299.0 | 60 | 295.0 | 61 | 141.0 | 24 | 94.0 | 17 | 79.0 | 11 | 92.0 | 14 | 117.0 | 18 | 199.0 | 35 | 200.0 | 33 | 365.0 | 76 | ||||||||||||||||||||||||||||||||||||||
| 55 | Luft/Wasser | Stiebel Eltron WPL 18 | 11.6 | 2009 | 179 | 4 | 3215.0 | 650 | 561.0 | 141 | 399.0 | 86 | 462.0 | 100 | 279.0 | 48 | 200.0 | 32 | 93.0 | 17 | 103.0 | 19 | 89.0 | 16 | 102.0 | 265.0 | 51 | 266.0 | 51 | 396.0 | 89 | |||||||||||||||||||||||||||||||||||||||
| 55 | Luft/Wasser | Stiebel Eltron WPL 18 | 11.6 | 2008 | 179 | 4 | 929.0 | 449.0 | 480.0 |
| NR | 55 |
| Username | Ralf670 |
| Einbaujahr der WP | 2008-08-08 |
| PLZ des Wohnortes | 37293 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Bi |
| Hersteller Typ | Stiebel Eltron WPL 18 |
| modulierend | |
| Leistung (0/35) | 11.6 kW |
| berechneter Primärenergiebedarf | 73.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 45 °C |
| WW Legionellenschaltung | |
| WW über WMZ erfasst | (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 3400 Watt DB |
| elektr. Verbrauch HP gem./DB | 328 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | > erfasst: |
| WMZ | |
| Mittlere Raumtemp. | 21.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 26.0 °C |
| Spreizung Heizkr. | 6.5 |
| Heizflaeche | 179 m² |
| Lüftung | Fenster |
| Personen | 4 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Wasserführendenkamin mit 9,0kw (4,4 kw Raumseitig 4,6 kw Wasserseitig) |