Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
636 | DV/Wasser | Ochsner GMDW 8 plus | 8.8 | 2018 | 165 | 4 | 1346.0 | 6252.0 | 817 | 4.64 | 264.0 | 1178.0 | 162 | 4.46 | 324.0 | 1399.0 | 198 | 4.32 | 225.0 | 985.0 | 138 | 4.38 | 33.0 | 156.0 | 21 | 4.73 | 14.0 | 36.0 | 7 | 2.57 | 2.0 | 8.0 | 1 | 4.00 | 1.0 | 7.0 | 1 | 7.00 | 1.0 | 4.0 | 1 | 4.00 | 13.0 | 74.0 | 7 | 5.69 | 41.0 | 216.0 | 23 | 5.27 | 174.0 | 929.0 | 104 | 5.34 | 254.0 | 1260.0 | 154 | 4.96 | ||||||||||||
636 | DV/Wasser | Ochsner GMDW 8 plus | 8.8 | 2017 | 165 | 4 | 1478.0 | 5973.0 | 885 | 4.04 | 382.0 | 1380.0 | 230 | 3.61 | 257.0 | 962.0 | 156 | 3.74 | 132.0 | 507.0 | 81 | 3.84 | 111.0 | 449.0 | 66 | 4.05 | 32.0 | 123.0 | 17 | 3.84 | 4.0 | 16.0 | 2 | 4.00 | 5.0 | 18.0 | 3 | 3.60 | 1.0 | 4.0 | 4.00 | 34.0 | 154.0 | 19 | 4.53 | 70.0 | 330.0 | 41 | 4.71 | 191.0 | 888.0 | 113 | 4.65 | 259.0 | 1142.0 | 157 | 4.41 | |||||||||||||
636 | DV/Wasser | Ochsner GMDW 8 plus | 8.8 | 2016 | 165 | 4 | 1332.0 | 4943.0 | 810 | 3.71 | 308.0 | 1066.0 | 188 | 3.46 | 208.0 | 734.0 | 128 | 3.53 | 177.0 | 630.0 | 108 | 3.56 | 52.0 | 199.0 | 32 | 3.83 | 28.0 | 96.0 | 15 | 3.43 | 0 | 0 | 0 | 0 | 0 | 0 | 5.0 | 20.0 | 3 | 4.00 | 2.0 | 13.0 | 1 | 6.50 | 88.0 | 367.0 | 52 | 4.17 | 179.0 | 736.0 | 109 | 4.11 | 285.0 | 1082.0 | 174 | 3.80 | ||||||||||||||
636 | DV/Wasser | Ochsner GMDW 8 plus | 8.8 | 2015 | 165 | 3 | 1192.0 | 4199.0 | 722 | 3.52 | 279.0 | 939.0 | 170 | 3.37 | 218.0 | 721.0 | 133 | 3.31 | 163.0 | 551.0 | 100 | 3.38 | 54.0 | 183.0 | 32 | 3.39 | 39.0 | 147.0 | 23 | 3.77 | 5.0 | 20.0 | 3 | 4.00 | 4.0 | 11.0 | 2 | 2.75 | 0 | 0 | 0 | 8.0 | 34.0 | 4 | 4.25 | 85.0 | 340.0 | 51 | 4.00 | 108.0 | 414.0 | 64 | 3.83 | 229.0 | 839.0 | 140 | 3.66 | |||||||||||||
636 | DV/Wasser | Ochsner GMDW 8 plus | 8.8 | 2014 | 165 | 3 | 1111.0 | 3939.0 | 672 | 3.55 | 270.0 | 911.0 | 164 | 3.37 | 213.0 | 700.0 | 131 | 3.29 | 67.0 | 233.0 | 40 | 3.48 | 38.0 | 136.0 | 25 | 3.58 | 32.0 | 122.0 | 19 | 3.81 | 2.0 | 6.0 | 1 | 3.00 | 2.0 | 8.0 | 1 | 4.00 | 1.0 | 3.0 | 0 | 3.00 | 14.0 | 54.0 | 8 | 3.86 | 57.0 | 233.0 | 34 | 4.09 | 151.0 | 581.0 | 89 | 3.85 | 264.0 | 952.0 | 160 | 3.61 | ||||||||||||
636 | DV/Wasser | Ochsner GMDW 8 plus | 8.8 | 2013 | 165 | 2 | 1376.0 | 4738.0 | 839 | 3.44 | 316.0 | 1055.0 | 192 | 3.34 | 253.0 | 829.0 | 155 | 3.28 | 197.0 | 651.0 | 122 | 3.30 | 87.0 | 294.0 | 55 | 3.38 | 27.0 | 102.0 | 16 | 3.78 | 10.0 | 33.0 | 5 | 3.30 | 0 | 0 | 0 | 1.0 | 2.0 | 0 | 2.00 | 25.0 | 105.0 | 16 | 4.20 | 36.0 | 142.0 | 21 | 3.94 | 174.0 | 655.0 | 105 | 3.76 | 250.0 | 870.0 | 152 | 3.48 | |||||||||||||
636 | DV/Wasser | Ochsner GMDW 8 plus | 8.8 | 2012 | 165 | 2 | 1202.0 | 4120.0 | 732 | 3.43 | 251.0 | 825.0 | 153 | 3.29 | 295.0 | 1024.0 | 180 | 3.47 | 85.0 | 182.0 | 53 | 2.14 | 51.0 | 183.0 | 32 | 3.59 | 14.0 | 56.0 | 9 | 4.00 | 5.0 | 15.0 | 2 | 3.00 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 68.0 | 271.0 | 40 | 3.99 | 151.0 | 573.0 | 90 | 3.79 | 282.0 | 991.0 | 173 | 3.51 | |||||||||||||||
636 | DV/Wasser | Ochsner GMDW 8 plus | 8.8 | 2011 | 165 | 2 | 1031.0 | 3486.0 | 622 | 3.38 | 251.0 | 802.0 | 153 | 3.20 | 163.0 | 528.0 | 100 | 3.24 | 43.0 | 141.0 | 32 | 3.28 | 23.0 | 78.0 | 7 | 3.39 | 2.0 | 7.0 | 1 | 3.50 | 9.0 | 27.0 | 4 | 3.00 | 1.0 | 2.0 | 0 | 2.00 | 0 | 0 | 0 | 81.0 | 319.0 | 49 | 3.94 | 201.0 | 715.0 | 121 | 3.56 | 257.0 | 867.0 | 155 | 3.37 |
NR | 636 |
Username | me68 |
Einbaujahr der WP | 2010-07-19 |
PLZ des Wohnortes | A- |
Bauart | DV/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Ochsner GMDW 8 plus |
modulierend | |
Leistung (0/35) | 8.8 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 49 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Flachkollektoren |
Tiefe | 1.4 m |
Fläche | 130 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1600 Watt DB |
elektr. Verbrauch HP gem./DB | 67 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Mittlere Raumtemp. | 22 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 165 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Flachkollektor: 7x75lfm, Abstand 50cm. Pufferspeicher: Ochsner Unifresh 800. Solaranlage für WW+Heizungsunterstützung: Sonnenkollektor: 3 Stk. Buderus Logasol SKN 3.0 (Gesamtbruttofläche: 7,14m2) Lt. Energieausweis EKZ=14 Warmwasser Temperatur: bis 31.12.2016: 47°C, ab 1.1.2017: 49°C, ab 3.1.2018: 48°C |