Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
665 | Sole/Wasser | Nibe F1245-6 | 6.3 | 2021 | 159 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
665 | Sole/Wasser | Nibe F1245-6 | 6.3 | 2015 | 159 | 4 | 2376.0 | 8069.0 | 1284 | 3.74 | 386.0 | 1605.0 | 232 | 4.16 | 342.0 | 1422.0 | 205 | 4.16 | 271.0 | 1112.0 | 161 | 4.10 | 185.0 | 694.0 | 101 | 3.75 | 110.0 | 283.0 | 44 | 2.57 | 67.0 | 98.0 | 17 | 1.46 | 47.0 | 38.0 | 7 | 0.81 | 62.0 | 53.0 | 10 | 0.85 | 109.0 | 284.0 | 46 | 2.61 | 221.0 | 124 | 265.0 | 1155.0 | 158 | 4.36 | 311.0 | 1325.0 | 179 | 4.26 | ||||||||||||||
665 | Sole/Wasser | Nibe F1245-6 | 6.3 | 2014 | 159 | 4 | 2499.0 | 9157.0 | 1367 | 3.66 | 419.0 | 1691.0 | 256 | 4.04 | 297.0 | 1171.0 | 174 | 3.94 | 290.0 | 1143.0 | 167 | 3.94 | 168.0 | 607.0 | 89 | 3.61 | 156.0 | 511.0 | 79 | 3.28 | 85.0 | 186.0 | 29 | 2.19 | 60.0 | 62.0 | 11 | 1.03 | 77.0 | 150.0 | 25 | 1.95 | 97.0 | 236.0 | 37 | 2.43 | 183.0 | 668.0 | 99 | 3.65 | 286.0 | 1178.0 | 172 | 4.12 | 381.0 | 1554.0 | 229 | 4.08 | ||||||||||||
665 | Sole/Wasser | Nibe F1245-6 | 6.3 | 2013 | 159 | 4 | 2811.0 | 10774.0 | 1574 | 3.83 | 461.0 | 1941.0 | 281 | 4.21 | 405.0 | 1703.0 | 246 | 4.20 | 465.0 | 1945.0 | 281 | 4.18 | 229.0 | 864.0 | 126 | 3.77 | 119.0 | 327.0 | 50 | 2.75 | 61.0 | 94.0 | 17 | 1.54 | 48.0 | 48.0 | 8 | 1.00 | 55.0 | 59.0 | 12 | 1.07 | 132.0 | 400.0 | 62 | 3.03 | 192.0 | 721.0 | 104 | 3.76 | 298.0 | 1249.0 | 180 | 4.19 | 346.0 | 1423.0 | 207 | 4.11 | ||||||||||||
665 | Sole/Wasser | Nibe F1245-6 | 6.3 | 2012 | 159 | 4 | 3314.0 | 12306.0 | 1765 | 3.71 | 577.0 | 2277.0 | 322 | 3.95 | 600.0 | 2332.0 | 338 | 3.89 | 391.0 | 1412.0 | 199 | 3.61 | 269.0 | 1059.0 | 150 | 3.94 | 134.0 | 369.0 | 54 | 2.75 | 89.0 | 190.0 | 29 | 2.13 | 66.0 | 67.0 | 12 | 1.02 | 65.0 | 72.0 | 14 | 1.11 | 116.0 | 314.0 | 47 | 2.71 | 249.0 | 986.0 | 140 | 3.96 | 326.0 | 1379.0 | 195 | 4.23 | 432.0 | 1849.0 | 265 | 4.28 | ||||||||||||
665 | Sole/Wasser | Nibe F1245-6 | 6.3 | 2011 | 159 | 4 | 1372.0 | 5588.0 | 785 | 4.07 | 363.0 | 1404.0 | 194 | 3.87 | 486.0 | 2046.0 | 285 | 4.21 | 523.0 | 2138.0 | 306 | 4.09 |
NR | 665 |
Username | vuffiraa |
Einbaujahr der WP | 2011-05-20 |
PLZ des Wohnortes | 14612 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe F1245-6 |
modulierend | |
Leistung (0/35) | 6.3 kW |
berechneter Primärenergiebedarf | 45.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 41 °C |
WW Legionellenschaltung | Ja |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 75.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Wandheizung |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 67 Watt |
elektr. Verbrauch WQ P gem./DB | 87 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 159 m² |
Lüftung | dezKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |