Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
672 | Luft/Wasser | Viessmann - Vitocal 300 A | 9.0 | 2013 | 200 | 3 | 2432.0 | 9994.0 | 1075 | 4.11 | 638.0 | 2668.0 | 288 | 4.18 | 533.0 | 2225.0 | 245 | 4.17 | 544.0 | 2222.0 | 251 | 4.08 | 265.0 | 1049.0 | 117 | 3.96 | 152.0 | 662.0 | 61 | 4.36 | 72.0 | 289.0 | 25 | 4.01 | 58.0 | 219.0 | 21 | 3.78 | 60.0 | 240.0 | 22 | 4.00 | 110.0 | 420.0 | 45 | 3.82 | ||||||||||||||||||||||||
672 | Luft/Wasser | Viessmann - Vitocal 300 A | 9.0 | 2012 | 200 | 3 | 3638.0 | 16537.7 | 1420 | 4.55 | 541.0 | 2503.0 | 222 | 4.63 | 893.0 | 3739.0 | 394 | 4.19 | 367.0 | 1883.0 | 157 | 5.13 | 312.0 | 1330.0 | 135 | 4.26 | 85.0 | 355.0 | 17 | 4.18 | 64.0 | 324.0 | 22 | 5.06 | 42.7 | 230.4 | 19 | 5.40 | 45.3 | 264.3 | 21 | 5.83 | 93.0 | 504.0 | 43 | 5.42 | 260.0 | 1286.0 | 118 | 4.95 | 395.0 | 1737.0 | 4.40 | 540.0 | 2382.0 | 272 | 4.41 | |||||||||||||
672 | Luft/Wasser | Viessmann - Vitocal 300 A | 9.0 | 2011 | 200 | 3 | 1252.0 | 5922.0 | 217 | 4.73 | 71.0 | 283.0 | 3.99 | 61.0 | 303.0 | 4.97 | 66.0 | 320.0 | 4.85 | 221.0 | 1160.0 | 5.25 | 398.0 | 1960.0 | 4.92 | 435.0 | 1896.0 | 217 | 4.36 |
NR | 672 |
Username | Seg |
Einbaujahr der WP | 2011-07-01 |
PLZ des Wohnortes | 35519 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Viessmann - Vitocal 300 A |
modulierend | Ja |
Leistung (0/35) | 9.0 kW |
berechneter Primärenergiebedarf | 68.7 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 47 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 8.0 |
Heizflaeche | 200 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |