Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
691 | DV/Wasser | Heliotherm HP08E-Web | 8.8 | 2024 | 220 | 2 | 1326.3 | 5865.0 | 680 | 4.42 | 460.0 | 2058.0 | 263 | 4.47 | 298.7 | 1342.0 | 152 | 4.49 | 243.5 | 1089.0 | 123 | 4.47 | 150.0 | 667.0 | 73 | 4.45 | 50.7 | 195.0 | 22 | 3.85 | 36.4 | 154.0 | 14 | 4.23 | 42.6 | 176.0 | 17 | 4.13 | 44.4 | 184.0 | 16 | 4.14 | ||||||||||||||||||||||||||||
691 | DV/Wasser | Heliotherm HP08E-Web | 8.8 | 2023 | 220 | 3 | 2435.3 | 11163.0 | 1228 | 4.58 | 454.0 | 2053.0 | 238 | 4.52 | 367.8 | 1632.0 | 195 | 4.44 | 319.4 | 1415.0 | 163 | 4.43 | 244.3 | 1101.0 | 122 | 4.51 | 69.3 | 283.0 | 30 | 4.08 | 47.6 | 199.0 | 19 | 4.18 | 47.6 | 199.0 | 19 | 4.18 | 35.7 | 155.0 | 13 | 4.34 | 36.9 | 155.0 | 14 | 4.20 | 126.1 | 658.0 | 63 | 5.22 | 295.0 | 1487.0 | 151 | 5.04 | 391.6 | 1826.0 | 201 | 4.66 | ||||||||||||
691 | DV/Wasser | Heliotherm HP08E-Web | 8.8 | 2022 | 220 | 3 | 2469.2 | 11171.0 | 1266 | 4.52 | 508.3 | 2260.0 | 270 | 4.45 | 319.6 | 1422.0 | 168 | 4.45 | 322.1 | 1414.0 | 168 | 4.39 | 238.6 | 1058.0 | 120 | 4.43 | 55.0 | 202.0 | 23 | 3.67 | 47.8 | 201.0 | 19 | 4.21 | 30.4 | 127.0 | 12 | 4.18 | 42.9 | 185.0 | 17 | 4.31 | 68.9 | 333.0 | 29 | 4.83 | 104.7 | 516.0 | 49 | 4.93 | 271.0 | 1358.0 | 149 | 5.01 | 459.9 | 2095.0 | 242 | 4.56 | ||||||||||||
691 | DV/Wasser | Heliotherm HP08E-Web | 8.8 | 2021 | 220 | 3 | 2741.1 | 12331.0 | 1416 | 4.50 | 465.7 | 2057.0 | 251 | 4.42 | 435.9 | 2018.0 | 229 | 4.63 | 343.8 | 1421.0 | 181 | 4.13 | 269.9 | 1183.0 | 139 | 4.38 | 106.8 | 440.0 | 49 | 4.12 | 46.8 | 184.0 | 21 | 3.93 | 45.8 | 189.0 | 19 | 4.13 | 46.7 | 189.0 | 19 | 4.05 | 44.4 | 189.0 | 21 | 4.26 | 179.6 | 917.0 | 91 | 5.11 | 326.3 | 1580.0 | 169 | 4.84 | 429.4 | 1964.0 | 227 | 4.57 | ||||||||||||
691 | DV/Wasser | Heliotherm HP08E-Web | 8.8 | 2020 | 220 | 3 | 2206.8 | 10015.0 | 1128 | 4.54 | 417.7 | 1851.0 | 224 | 4.43 | 312.3 | 1425.0 | 166 | 4.56 | 303.2 | 1351.0 | 159 | 4.46 | 118.6 | 493.0 | 58 | 4.16 | 92.6 | 407.0 | 44 | 4.40 | 41.3 | 161.0 | 16 | 3.90 | 39.1 | 160.0 | 15 | 4.09 | 33.6 | 139.0 | 13 | 4.14 | 37.2 | 157.0 | 15 | 4.22 | 169.3 | 849.0 | 84 | 5.01 | 255.3 | 1241.0 | 130 | 4.86 | 386.6 | 1781.0 | 204 | 4.61 | ||||||||||||
691 | DV/Wasser | Heliotherm HP08E-Web | 8.8 | 2019 | 220 | 3 | 2322.1 | 10455.4 | 1212 | 4.50 | 470.5 | 2131.0 | 254 | 4.53 | 341.0 | 1423.0 | 183 | 4.17 | 304.3 | 1322.0 | 165 | 4.34 | 161.9 | 690.0 | 81 | 4.26 | 101.7 | 456.0 | 49 | 4.48 | 30.9 | 125.0 | 14 | 4.05 | 29.9 | 124.0 | 14 | 4.15 | 35.3 | 142.0 | 15 | 4.02 | 32.0 | 131.4 | 14 | 4.11 | 150.8 | 769.0 | 72 | 5.10 | 289.6 | 1403.0 | 152 | 4.84 | 374.2 | 1739.0 | 199 | 4.65 | ||||||||||||
691 | DV/Wasser | Heliotherm HP08E-Web | 8.8 | 2018 | 220 | 3 | 2427.6 | 11189.0 | 1259 | 4.61 | 418.7 | 1918.0 | 223 | 4.58 | 453.0 | 2055.0 | 242 | 4.54 | 410.1 | 1890.0 | 218 | 4.61 | 105.6 | 434.0 | 49 | 4.11 | 44.1 | 170.0 | 17 | 3.85 | 33.3 | 201.0 | 13 | 6.04 | 33.2 | 202.0 | 12 | 6.08 | 30.6 | 178.0 | 13 | 5.82 | 39.0 | 165.0 | 19 | 4.23 | 154.6 | 751.0 | 76 | 4.86 | 323.7 | 1510.0 | 172 | 4.66 | 381.7 | 1715.0 | 205 | 4.49 | ||||||||||||
691 | DV/Wasser | Heliotherm HP08E-Web | 8.8 | 2017 | 220 | 4 | 2473.2 | 11722.0 | 1284 | 4.74 | 490.5 | 2296.0 | 265 | 4.68 | 371.0 | 1793.0 | 193 | 4.83 | 271.4 | 1215.0 | 142 | 4.48 | 212.0 | 969.0 | 106 | 4.57 | 171.5 | 730.0 | 69 | 4.26 | 37.7 | 165.0 | 13 | 4.38 | 55.6 | 256.0 | 23 | 4.60 | 143.1 | 757.0 | 71 | 5.29 | 292.0 | 1511.0 | 175 | 5.17 | 428.4 | 2030.0 | 227 | 4.74 | ||||||||||||||||||||
691 | DV/Wasser | Heliotherm HP08E-Web | 8.8 | 2016 | 220 | 4 | 2504.8 | 12828.0 | 1311 | 5.12 | 470.7 | 2531.0 | 258 | 5.38 | 387.1 | 2001.0 | 210 | 5.17 | 359.0 | 1835.0 | 193 | 5.11 | 187.2 | 969.0 | 96 | 5.18 | 61.1 | 275.0 | 25 | 4.50 | 38.1 | 175.0 | 15 | 4.59 | 31.8 | 154.0 | 12 | 4.84 | 36.3 | 172.0 | 13 | 4.74 | 34.1 | 155.0 | 14 | 4.55 | 173.0 | 949.0 | 87 | 5.49 | 329.3 | 1701.0 | 174 | 5.17 | 397.1 | 1911.0 | 214 | 4.81 | ||||||||||||
691 | DV/Wasser | Heliotherm HP08E-Web | 8.8 | 2015 | 220 | 4 | 2324.5 | 12772.0 | 1195 | 5.49 | 421.0 | 2283.0 | 228 | 5.42 | 383.7 | 2058.0 | 206 | 5.36 | 315.7 | 1654.0 | 164 | 5.24 | 191.3 | 994.0 | 95 | 5.20 | 81.8 | 384.0 | 32 | 4.69 | 35.1 | 170.0 | 16 | 4.84 | 29.3 | 148.0 | 12 | 5.05 | 35.6 | 187.0 | 14 | 5.25 | 48.1 | 264.0 | 18 | 5.49 | 213.8 | 1342.0 | 110 | 6.28 | 255.4 | 1520.0 | 134 | 5.95 | 313.7 | 1768.0 | 166 | 5.64 | ||||||||||||
691 | DV/Wasser | Heliotherm HP08E-Web | 8.8 | 2014 | 220 | 4 | 2172.0 | 11978.0 | 1103 | 5.51 | 448.0 | 2532.0 | 241 | 5.65 | 318.0 | 1706.0 | 166 | 5.36 | 267.0 | 1394.0 | 136 | 5.22 | 134.0 | 696.0 | 64 | 5.19 | 81.0 | 393.0 | 32 | 4.85 | 39.0 | 191.0 | 16 | 4.90 | 37.2 | 190.0 | 16 | 5.11 | 35.0 | 182.0 | 15 | 5.20 | 36.8 | 187.0 | 14 | 5.08 | 108.1 | 644.0 | 51 | 5.96 | 253.2 | 1531.0 | 131 | 6.05 | 414.7 | 2332.0 | 221 | 5.62 | ||||||||||||
691 | DV/Wasser | Heliotherm HP08E-Web | 8.8 | 2013 | 220 | 4 | 2566.3 | 14014.0 | 1309 | 5.46 | 486.3 | 2554.0 | 259 | 5.25 | 435.3 | 2342.0 | 234 | 5.38 | 452.4 | 2412.0 | 241 | 5.33 | 206.2 | 1027.0 | 100 | 4.98 | 76.0 | 351.0 | 30 | 4.62 | 37.2 | 186.0 | 15 | 5.00 | 31.7 | 165.0 | 12 | 5.21 | 26.1 | 142.0 | 10 | 5.44 | 52.7 | 291.0 | 21 | 5.52 | 129.2 | 739.0 | 56 | 5.72 | 270.3 | 1693.0 | 140 | 6.26 | 362.9 | 2112.0 | 191 | 5.82 | ||||||||||||
691 | DV/Wasser | Heliotherm HP08E-Web | 8.8 | 2012 | 220 | 4 | 2653.8 | 13467.0 | 1369 | 5.07 | 485.0 | 2370.0 | 262 | 4.89 | 507.0 | 2555.0 | 275 | 5.04 | 290.0 | 1432.0 | 150 | 4.94 | 227.0 | 1105.0 | 114 | 4.87 | 56.0 | 259.0 | 25 | 4.63 | 46.0 | 209.0 | 18 | 4.54 | 39.0 | 188.0 | 17 | 4.82 | 35.0 | 173.0 | 14 | 4.94 | 34.8 | 170.0 | 14 | 4.89 | 176.0 | 953.0 | 80 | 5.41 | 297.0 | 1636.0 | 155 | 5.51 | 461.0 | 2417.0 | 245 | 5.24 | ||||||||||||
691 | DV/Wasser | Heliotherm HP08E-Web | 8.8 | 2011 | 220 | 4 | 2954.0 | 13906.0 | 1667 | 4.71 | 324.0 | 1512.0 | 190 | 4.67 | 324.0 | 1512.0 | 190 | 4.67 | 324.0 | 1512.0 | 190 | 4.67 | 324.0 | 1512.0 | 190 | 4.67 | 324.0 | 1512.0 | 190 | 4.67 | 324.0 | 1512.0 | 190 | 4.67 | 41.0 | 172.0 | 18 | 4.20 | 41.0 | 172.0 | 18 | 4.20 | 41.0 | 172.0 | 18 | 4.20 | 151.0 | 759.0 | 76 | 5.03 | 323.0 | 1584.0 | 174 | 4.90 | 413.0 | 1975.0 | 223 | 4.78 | ||||||||||||
691 | DV/Wasser | Heliotherm HP08E-Web | 8.8 | 2010 | 220 | 4 | 1296.0 | 6048.0 | 760 | 4.67 | 324.0 | 1512.0 | 190 | 4.67 | 324.0 | 1512.0 | 190 | 4.67 | 324.0 | 1512.0 | 190 | 4.67 | 324.0 | 1512.0 | 190 | 4.67 |
NR | 691 |
Username | ersthausbauer-alt |
Einbaujahr der WP | 2010-08-26 |
PLZ des Wohnortes | 39126 |
Bauart | DV/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Heliotherm HP08E-Web |
modulierend | Nein |
Leistung (0/35) | 8.8 kW |
berechneter Primärenergiebedarf | 37.2 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Flachkollektoren |
Tiefe | 1.2 m |
Fläche | 180 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1440 Watt gem. |
elektr. Verbrauch HP gem./DB | 90 Watt |
elektr. Verbrauch WQ P gem./DB | 40 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | extern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 3.0 °C |
Heizung max. Vorlauf Temp. | 29.0 °C |
Spreizung Heizkr. | 6.0 |
Heizflaeche | 220 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | nein |
Bemerkungen | Vom September 2010 bis Juni2011 sind alle Werte nur Generiert aus Gesamtdaten. Inklusive Ströme :HKP und Zirku Leitung und BWP errechnet nach Betriebdauer+ Leistung Ab Juli Externer Stromzähler mit allen Hilfströmen. Ab Oktober 2011 sind Daten Pro Tag vorhanden Oktober 2024 Verdichter Tot |