Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
782 | Sole/Wasser | Nibe 1145 | 8.0 | 2016 | 350 | 3 | 1709.0 | 8949.0 | 937 | 5.24 | 514.0 | 2673.0 | 295 | 5.20 | 364.0 | 1920.0 | 206 | 5.27 | 284.0 | 1549.0 | 160 | 5.45 | 122.0 | 658.0 | 65 | 5.39 | 83.0 | 417.0 | 42 | 5.02 | 51.0 | 235.0 | 24 | 4.61 | 53.0 | 248.0 | 25 | 4.68 | 52.0 | 244.0 | 24 | 4.69 | 49.0 | 232.0 | 23 | 4.73 | 137.0 | 773.0 | 73 | 5.64 | ||||||||||||||||||||
782 | Sole/Wasser | Nibe 1145 | 8.0 | 2015 | 350 | 3 | 2346.0 | 11757.0 | 1270 | 5.01 | 560.0 | 2582.0 | 311 | 4.61 | 415.0 | 2048.0 | 233 | 4.93 | 277.0 | 1422.0 | 155 | 5.13 | 134.0 | 672.0 | 71 | 5.01 | 91.0 | 453.0 | 45 | 4.98 | 56.0 | 262.0 | 26 | 4.68 | 36.0 | 164.0 | 16 | 4.56 | 39.0 | 181.0 | 18 | 4.64 | 43.0 | 194.0 | 20 | 4.51 | 138.0 | 731.0 | 74 | 5.30 | 209.0 | 1123.0 | 111 | 5.37 | 348.0 | 1925.0 | 190 | 5.53 | ||||||||||||
782 | Sole/Wasser | Nibe 1145 | 8.0 | 2014 | 350 | 3 | 2886.0 | 12786.0 | 1566 | 4.43 | 700.0 | 2940.0 | 388 | 4.20 | 457.0 | 1986.0 | 252 | 4.35 | 250.0 | 1182.0 | 137 | 4.73 | 130.0 | 602.0 | 69 | 4.63 | 109.0 | 509.0 | 56 | 4.67 | 48.0 | 200.0 | 23 | 4.17 | 51.0 | 217.0 | 24 | 4.25 | 49.0 | 202.0 | 23 | 4.12 | 46.0 | 196.0 | 21 | 4.26 | 137.0 | 642.0 | 73 | 4.69 | 353.0 | 1681.0 | 193 | 4.76 | 556.0 | 2429.0 | 307 | 4.37 | ||||||||||||
782 | Sole/Wasser | Nibe 1145 | 8.0 | 2013 | 350 | 3 | 3986.0 | 16508.0 | 2126 | 4.14 | 778.0 | 3119.0 | 427 | 4.01 | 674.0 | 2705.0 | 372 | 4.01 | 351.0 | 1465.0 | 186 | 4.17 | 169.0 | 687.0 | 85 | 4.07 | 76.0 | 318.0 | 37 | 4.18 | 75.0 | 306.0 | 35 | 4.08 | 66.0 | 274.0 | 32 | 4.15 | 57.0 | 238.0 | 25 | 4.18 | 425.0 | 1576.0 | 207 | 3.71 | 158.0 | 751.0 | 84 | 4.75 | 453.0 | 2079.0 | 248 | 4.59 | 704.0 | 2990.0 | 388 | 4.25 | ||||||||||||
782 | Sole/Wasser | Nibe 1145 | 8.0 | 2012 | 350 | 3 | 3945.0 | 16210.0 | 2127 | 4.11 | 851.0 | 3283.0 | 456 | 3.86 | 922.0 | 3415.0 | 513 | 3.70 | 352.0 | 1528.0 | 190 | 4.34 | 207.0 | 973.0 | 112 | 4.70 | 67.0 | 304.0 | 33 | 4.54 | 49.0 | 214.0 | 24 | 4.37 | 51.0 | 224.0 | 24 | 4.39 | 43.0 | 192.0 | 20 | 4.47 | 45.0 | 200.0 | 21 | 4.44 | 194.0 | 886.0 | 100 | 4.57 | 441.0 | 2014.0 | 241 | 4.57 | 723.0 | 2977.0 | 393 | 4.12 | ||||||||||||
782 | Sole/Wasser | Nibe 1145 | 8.0 | 2011 | 350 | 3 | 5453.0 | 20445.0 | 720 | 3.75 | 1140.0 | 3842.0 | 3.37 | 1138.0 | 3835.0 | 3.37 | 652.0 | 2537.0 | 3.89 | 354.0 | 1472.0 | 4.16 | 166.0 | 703.0 | 4.23 | 60.0 | 251.0 | 4.18 | 62.0 | 264.0 | 4.26 | 58.0 | 247.0 | 4.26 | 54.0 | 222.0 | 4.11 | 398.0 | 1666.0 | 4.19 | 636.0 | 2498.0 | 325 | 3.93 | 735.0 | 2908.0 | 395 | 3.96 |
NR | 782 |
Username | dyarne |
Einbaujahr der WP | 2010-10-15 |
PLZ des Wohnortes | A-4611 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe 1145 |
modulierend | |
Leistung (0/35) | 8.0 kW |
berechneter Primärenergiebedarf | 25.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 46 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 1 Erdbohrung |
Tiefe | 160.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 1700 Watt DB |
elektr. Verbrauch HP gem./DB | 7 Watt |
elektr. Verbrauch WQ P gem./DB | 35 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 5.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 350 m² |
Lüftung | Fenster |
Personen | >=3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | Unterstützung bei Planung & Ausführung, Musteranlagen in der Nähe |
Bemerkungen | ESH - thermische sanierung der gebäudehülle noch nicht abgeschlossen. - wp ürsprünglich an kombischichtpuffer, 2011/12 erst stichanbindung, dann direktheizung auf heizkörper; ww per friwa-system vom schichtpuffer; solare anbindung vorbereitet - september 2013 im eg tlw fbh eingebaut und ausgeheizt! - anfang 2015 dach gedämmt, dachboden im ausbau in warmer hülle - anfang 2015 sole gespült, schaumbildung durch gasdiffusion in die sole -> +10% effizienz --> seit 2016/11 auf modulierende wp umgestellt -> KNV 1155-6 siehe nr.1892 http://www.waermepumpen-verbrauchsdatenbank.de/index.php?button=verbrauchanl&showver=1892 |