Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
839 | Sole/Wasser | Viessmann Vitocal 300 G Typ BWC 301 | 7.7 | 2025 | 140 | 3 | 1432.0 | 6303.0 | 679 | 4.40 | 525.0 | 2352.0 | 252 | 4.48 | 494.0 | 2104.0 | 229 | 4.26 | 413.0 | 1847.0 | 198 | 4.47 | ||||||||||||||||||||||||||||||||||||||||||||||||
839 | Sole/Wasser | Viessmann Vitocal 300 G Typ BWC 301 | 7.7 | 2024 | 140 | 3 | 3174.0 | 13257.0 | 1428 | 4.18 | 555.0 | 2394.0 | 266 | 4.31 | 434.0 | 1901.0 | 208 | 4.38 | 415.0 | 1816.0 | 196 | 4.38 | 300.0 | 1374.0 | 146 | 4.58 | 140.0 | 347.0 | 30 | 2.48 | 90.0 | 246.0 | 38 | 2.73 | 70.0 | 194.0 | 24 | 2.77 | 70.0 | 187.0 | 24 | 2.67 | 100.0 | 263.0 | 29 | 2.63 | 230.0 | 986.0 | 99 | 4.29 | 353.0 | 1637.0 | 169 | 4.64 | 417.0 | 1912.0 | 199 | 4.59 | ||||||||||||
839 | Sole/Wasser | Viessmann Vitocal 300 G Typ BWC 301 | 7.7 | 2023 | 140 | 3 | 3068.0 | 12879.0 | 1425 | 4.20 | 432.0 | 1870.0 | 208 | 4.33 | 394.0 | 1709.0 | 191 | 4.34 | 402.0 | 1756.0 | 193 | 4.37 | 311.0 | 1344.0 | 145 | 4.32 | 199.0 | 829.0 | 88 | 4.17 | 64.0 | 178.0 | 24 | 2.78 | 70.0 | 195.0 | 25 | 2.79 | 67.0 | 178.0 | 24 | 2.66 | 68.0 | 201.0 | 25 | 2.96 | 216.0 | 889.0 | 96 | 4.12 | 376.0 | 1670.0 | 179 | 4.44 | 469.0 | 2060.0 | 227 | 4.39 | ||||||||||||
839 | Sole/Wasser | Viessmann Vitocal 300 G Typ BWC 301 | 7.7 | 2022 | 140 | 3 | 3298.0 | 13345.0 | 1526 | 4.05 | 491.0 | 2074.0 | 238 | 4.22 | 441.0 | 1756.0 | 215 | 3.98 | 457.0 | 1859.0 | 219 | 4.07 | 363.0 | 1469.0 | 120 | 4.05 | 171.0 | 646.0 | 125 | 3.78 | 107.0 | 340.0 | 43 | 3.18 | 80.0 | 213.0 | 29 | 2.66 | 70.0 | 182.0 | 24 | 2.60 | 113.0 | 365.0 | 44 | 3.23 | 201.0 | 905.0 | 86 | 4.50 | 336.0 | 1530.0 | 158 | 4.55 | 468.0 | 2006.0 | 225 | 4.29 | ||||||||||||
839 | Sole/Wasser | Viessmann Vitocal 300 G Typ BWC 301 | 7.7 | 2021 | 140 | 3 | 3650.0 | 14422.0 | 1707 | 3.95 | 533.0 | 2147.0 | 258 | 4.03 | 496.0 | 1979.0 | 241 | 3.99 | 455.0 | 1856.0 | 221 | 4.08 | 393.0 | 1602.0 | 188 | 4.08 | 292.0 | 1167.0 | 134 | 4.00 | 81.0 | 240.0 | 32 | 2.96 | 73.0 | 188.0 | 25 | 2.58 | 99.0 | 311.0 | 37 | 3.14 | 131.0 | 454.0 | 53 | 3.47 | 254.0 | 1018.0 | 114 | 4.01 | 338.0 | 1410.0 | 161 | 4.17 | 505.0 | 2050.0 | 243 | 4.06 | ||||||||||||
839 | Sole/Wasser | Viessmann Vitocal 300 G Typ BWC 301 | 7.7 | 2020 | 140 | 3 | 3534.0 | 13696.0 | 1636 | 3.88 | 524.0 | 2083.0 | 251 | 3.98 | 482.0 | 1906.0 | 234 | 3.95 | 485.0 | 1913.0 | 233 | 3.94 | 321.0 | 1235.0 | 149 | 3.85 | 211.0 | 799.0 | 94 | 3.79 | 93.0 | 285.0 | 36 | 3.06 | 114.0 | 362.0 | 44 | 3.18 | 75.0 | 205.0 | 26 | 2.73 | 151.0 | 524.0 | 60 | 3.47 | 253.0 | 1019.0 | 115 | 4.03 | 364.0 | 1492.0 | 172 | 4.10 | 461.0 | 1873.0 | 222 | 4.06 | ||||||||||||
839 | Sole/Wasser | Viessmann Vitocal 300 G Typ BWC 301 | 7.7 | 2019 | 140 | 3 | 3657.0 | 14370.0 | 1700 | 3.93 | 529.0 | 2119.0 | 256 | 4.01 | 462.0 | 1848.0 | 222 | 4.00 | 463.0 | 1858.0 | 221 | 4.01 | 319.0 | 1263.0 | 148 | 3.96 | 254.0 | 987.0 | 114 | 3.89 | 81.0 | 252.0 | 31 | 3.11 | 100.0 | 327.0 | 39 | 3.27 | 63.0 | 187.0 | 23 | 2.97 | 139.0 | 505.0 | 56 | 3.63 | 318.0 | 1283.0 | 145 | 4.03 | 403.0 | 1650.0 | 193 | 4.09 | 526.0 | 2091.0 | 252 | 3.98 | ||||||||||||
839 | Sole/Wasser | Viessmann Vitocal 300 G Typ BWC 301 | 7.7 | 2018 | 140 | 3 | 3524.0 | 13939.0 | 1679 | 3.96 | 556.0 | 2255.0 | 270 | 4.06 | 612.0 | 2381.0 | 295 | 3.89 | 564.0 | 2419.0 | 301 | 4.29 | 279.0 | 1072.0 | 129 | 3.84 | 114.0 | 399.0 | 47 | 3.50 | 80.0 | 248.0 | 31 | 3.10 | 59.0 | 159.0 | 21 | 2.69 | 66.0 | 185.0 | 23 | 2.80 | 103.0 | 383.0 | 44 | 3.72 | 245.0 | 983.0 | 112 | 4.01 | 375.0 | 1546.0 | 180 | 4.12 | 471.0 | 1909.0 | 226 | 4.05 | ||||||||||||
839 | Sole/Wasser | Viessmann Vitocal 300 G Typ BWC 301 | 7.7 | 2017 | 140 | 3 | 3597.0 | 14116.0 | 1639 | 3.92 | 539.0 | 2249.0 | 266 | 4.17 | 461.0 | 1908.0 | 227 | 4.14 | 393.0 | 1617.0 | 189 | 4.11 | 367.0 | 1487.0 | 174 | 4.05 | 174.0 | 662.0 | 81 | 3.80 | 97.0 | 300.0 | 33 | 3.09 | 72.0 | 202.0 | 26 | 2.81 | 95.0 | 314.0 | 36 | 3.31 | 178.0 | 699.0 | 75 | 3.93 | 259.0 | 1048.0 | 115 | 4.05 | 385.0 | 1646.0 | 186 | 4.28 | 577.0 | 1984.0 | 231 | 3.44 | ||||||||||||
839 | Sole/Wasser | Viessmann Vitocal 300 G Typ BWC 301 | 7.7 | 2016 | 140 | 3 | 3349.0 | 13394.0 | 1541 | 4.00 | 489.0 | 2066.0 | 238 | 4.22 | 461.0 | 1923.0 | 223 | 4.17 | 458.0 | 1899.0 | 219 | 4.15 | 336.0 | 1339.0 | 152 | 3.99 | 131.0 | 445.0 | 51 | 3.40 | 73.0 | 194.0 | 26 | 2.66 | 75.0 | 196.0 | 26 | 2.61 | 78.0 | 194.0 | 26 | 2.49 | 72.0 | 209.0 | 26 | 2.90 | 281.0 | 1140.0 | 123 | 4.06 | 424.0 | 1796.0 | 202 | 4.24 | 471.0 | 1993.0 | 229 | 4.23 | ||||||||||||
839 | Sole/Wasser | Viessmann Vitocal 300 G Typ BWC 301 | 7.7 | 2015 | 140 | 3 | 3287.0 | 13737.0 | 1511 | 4.18 | 497.0 | 2176.0 | 245 | 4.38 | 417.0 | 1851.0 | 206 | 4.44 | 430.0 | 1872.0 | 207 | 4.35 | 328.0 | 1401.0 | 153 | 4.27 | 200.0 | 788.0 | 83 | 3.94 | 103.0 | 360.0 | 37 | 3.50 | 64.0 | 219.0 | 23 | 3.42 | 63.0 | 219.0 | 23 | 3.48 | 138.0 | 553.0 | 57 | 4.01 | 311.0 | 1315.0 | 142 | 4.23 | 342.0 | 1390.0 | 155 | 4.06 | 394.0 | 1593.0 | 180 | 4.04 | ||||||||||||
839 | Sole/Wasser | Viessmann Vitocal 300 G Typ BWC 301 | 7.7 | 2014 | 140 | 2 | 2875.0 | 12238.0 | 1314 | 4.26 | 487.0 | 2211.0 | 244 | 4.54 | 363.0 | 1642.0 | 180 | 4.52 | 319.0 | 1399.0 | 152 | 4.39 | 212.0 | 888.0 | 94 | 4.19 | 135.0 | 478.0 | 49 | 3.54 | 82.0 | 244.0 | 24 | 2.98 | 49.0 | 161.0 | 16 | 3.29 | 86.0 | 288.0 | 29 | 3.35 | 76.0 | 248.0 | 25 | 3.26 | 221.0 | 907.0 | 93 | 4.10 | 342.0 | 1525.0 | 160 | 4.46 | 503.0 | 2247.0 | 248 | 4.47 | ||||||||||||
839 | Sole/Wasser | Viessmann Vitocal 300 G Typ BWC 301 | 7.7 | 2013 | 140 | 3 | 3309.0 | 14860.0 | 1616 | 4.49 | 517.0 | 2323.0 | 266 | 4.49 | 483.0 | 2206.0 | 247 | 4.57 | 528.0 | 2379.0 | 269 | 4.51 | 309.0 | 1409.0 | 148 | 4.56 | 162.0 | 705.0 | 72 | 4.35 | 78.0 | 304.0 | 31 | 3.90 | 51.0 | 184.0 | 19 | 3.61 | 61.0 | 213.0 | 22 | 3.49 | 111.0 | 480.0 | 48 | 4.32 | 250.0 | 1140.0 | 117 | 4.56 | 356.0 | 1677.0 | 177 | 4.71 | 403.0 | 1840.0 | 200 | 4.57 | ||||||||||||
839 | Sole/Wasser | Viessmann Vitocal 300 G Typ BWC 301 | 7.7 | 2012 | 140 | 3 | 3457.0 | 15427.0 | 1675 | 4.46 | 486.0 | 2324.0 | 246 | 4.78 | 556.0 | 2497.0 | 283 | 4.49 | 364.0 | 1655.0 | 179 | 4.55 | 337.0 | 1486.0 | 164 | 4.41 | 133.0 | 560.0 | 59 | 4.21 | 109.0 | 405.0 | 46 | 3.72 | 87.0 | 315.0 | 33 | 3.62 | 78.0 | 290.0 | 29 | 3.72 | 130.0 | 570.0 | 56 | 4.38 | 296.0 | 1351.0 | 139 | 4.56 | 382.0 | 1721.0 | 188 | 4.51 | 499.0 | 2253.0 | 253 | 4.52 |
NR | 839 |
Username | diefri |
Einbaujahr der WP | 2011-10-04 |
PLZ des Wohnortes | 21717 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Viessmann Vitocal 300 G Typ BWC 301 |
modulierend | Ja |
Leistung (0/35) | 7.7 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 90.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 1640 Watt DB |
elektr. Verbrauch HP gem./DB | 30 Watt |
elektr. Verbrauch WQ P gem./DB | 30 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | extern_geeicht |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 7.0 °C |
Heizung max. Vorlauf Temp. | 33.0 °C |
Spreizung Heizkr. | 6.0 |
Heizflaeche | 140 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Systemtrennung FBH mit effiz. Pumpe, kein Puffer |