Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
852 | Sole/Wasser | Vaillant VWS 82/3 | 7.8 | 2016 | 157 | 4 | 2044.0 | 9186.0 | 1031 | 4.11 | 672.0 | 2947.0 | 340 | 4.39 | 2290.0 | 257 | 506.0 | 2263.0 | 252 | 4.47 | 499.0 | 1686.0 | 182 | 3.38 | 367.0 | |||||||||||||||||||||||||||||||||||||||||||||
852 | Sole/Wasser | Vaillant VWS 82/3 | 7.8 | 2015 | 157 | 4 | 3448.0 | 15961.0 | 1712 | 4.63 | 522.0 | 2426.0 | 270 | 4.65 | 510.0 | 2324.0 | 263 | 4.56 | 418.0 | 1950.0 | 214 | 4.67 | 304.0 | 1420.0 | 151 | 4.67 | 182.0 | 847.0 | 86 | 4.65 | 102.0 | 441.0 | 44 | 4.32 | 77.0 | 302.0 | 30 | 3.92 | 67.0 | 233.0 | 22 | 3.48 | 138.0 | 656.0 | 64 | 4.75 | 325.0 | 1573.0 | 162 | 4.84 | 387.0 | 1778.0 | 194 | 4.59 | 416.0 | 2011.0 | 212 | 4.83 | ||||||||||||
852 | Sole/Wasser | Vaillant VWS 82/3 | 7.8 | 2014 | 157 | 4 | 2988.0 | 13757.0 | 1482 | 4.60 | 565.0 | 2593.0 | 296 | 4.59 | 387.0 | 1812.0 | 200 | 4.68 | 328.0 | 1533.0 | 164 | 4.67 | 218.0 | 1000.0 | 105 | 4.59 | 151.0 | 682.0 | 70 | 4.52 | 81.0 | 322.0 | 32 | 3.98 | 53.0 | 200.0 | 20 | 3.77 | 72.0 | 288.0 | 28 | 4.00 | 87.0 | 359.0 | 35 | 4.13 | 164.0 | 781.0 | 78 | 4.76 | 369.0 | 1775.0 | 187 | 4.81 | 513.0 | 2412.0 | 267 | 4.70 | ||||||||||||
852 | Sole/Wasser | Vaillant VWS 82/3 | 7.8 | 2013 | 157 | 3 | 3276.0 | 15148.0 | 1659 | 4.62 | 536.0 | 2504.0 | 286 | 4.67 | 475.0 | 2204.0 | 248 | 4.64 | 511.0 | 2345.0 | 266 | 4.59 | 272.0 | 1268.0 | 137 | 4.66 | 115.0 | 522.0 | 54 | 4.54 | 73.0 | 269.0 | 26 | 3.68 | 40.0 | 150.0 | 15 | 3.75 | 52.0 | 174.0 | 17 | 3.35 | 120.0 | 543.0 | 56 | 4.53 | 213.0 | 1026.0 | 103 | 4.82 | 421.0 | 2015.0 | 218 | 4.79 | 448.0 | 2128.0 | 233 | 4.75 | ||||||||||||
852 | Sole/Wasser | Vaillant VWS 82/3 | 7.8 | 2012 | 157 | 3 | 2360.0 | 10868.0 | 902 | 4.61 | 341.0 | 1604.0 | 4.70 | 144.0 | 668.0 | 4.64 | 106.0 | 462.0 | 4.36 | 52.0 | 192.0 | 18 | 3.69 | 64.0 | 239.0 | 23 | 3.73 | 107.0 | 509.0 | 51 | 4.76 | 317.0 | 1542.0 | 160 | 4.86 | 532.0 | 2538.0 | 283 | 4.77 | 697.0 | 3114.0 | 367 | 4.47 |
NR | 852 |
Username | bleicher6 |
Einbaujahr der WP | 2011-12-01 |
PLZ des Wohnortes | 19053 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Vaillant VWS 82/3 |
modulierend | |
Leistung (0/35) | 7.8 kW |
berechneter Primärenergiebedarf | 59.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 1 Erdbohrung |
Tiefe | 134.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 10 Watt gem. |
elektr. Verbrauch HP gem./DB | 60 Watt |
elektr. Verbrauch WQ P gem./DB | 60 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 157 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Neubau - 36,5cm Poroton T9 Dachgeschoss (100qm Höhe 5m 45 Grad Dachneigung) noch nicht vollständig gedämmt. Dampfbremse noch nicht angebracht, 200mm 035 Zwischensparren-Dämmung vorerst eingebracht. Dachgeschoss unbeheizt, obere Stahlbetondecke erst Mitte Dezember 2012 teilweise gedämmt. Datenerfassung ab April 2012 Zähler erfasst auch Steuerung Zirkulations- und Umwälzpumpen Keine Nachtabsenkung |