Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
92 | Sole/Wasser | Vissmann Vitocal BWH113 | 16.2 | 2013 | 193 | 3 | 1130.9 | 4037.0 | 207 | 3.57 | 1130.9 | 4037.0 | 207 | 3.57 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
92 | Sole/Wasser | Vissmann Vitocal BWH113 | 16.2 | 2012 | 193 | 3 | 3955.9 | 14778.0 | 737 | 3.74 | 935.6 | 3530.0 | 181 | 3.77 | 1173.0 | 4177.0 | 219 | 3.56 | 519.0 | 1999.0 | 85 | 3.85 | 439.8 | 1692.0 | 86 | 3.85 | 151.0 | 559.0 | 28 | 3.70 | 75.0 | 276.0 | 13 | 3.68 | 39.9 | 144.0 | 7 | 3.61 | 35.7 | 126.0 | 6 | 3.53 | 169.4 | 655.0 | 32 | 3.87 | 417.5 | 1620.0 | 80 | 3.88 | ||||||||||||||||||||
92 | Sole/Wasser | Vissmann Vitocal BWH113 | 16.2 | 2011 | 193 | 3 | 4904.3 | 18207.0 | 927 | 3.71 | 1017.4 | 3665.0 | 192 | 3.60 | 820.0 | 3016.0 | 158 | 3.68 | 678.3 | 2515.0 | 131 | 3.71 | 220.8 | 813.0 | 41 | 3.68 | 66.9 | 240.0 | 12 | 3.59 | 39.1 | 133.0 | 6 | 3.40 | 73.9 | 265.0 | 13 | 3.59 | 64.4 | 234.0 | 11 | 3.63 | 122.7 | 467.0 | 22 | 3.81 | 368.0 | 1411.0 | 69 | 3.83 | 597.8 | 2274.0 | 112 | 3.80 | 835.0 | 3174.0 | 160 | 3.80 | ||||||||||||
92 | Sole/Wasser | Vissmann Vitocal BWH113 | 16.2 | 2010 | 193 | 3 | 6708.0 | 23613.0 | 1225 | 3.52 | 1243.0 | 4298.0 | 223 | 3.46 | 959.0 | 3397.0 | 180 | 3.54 | 732.3 | 2631.0 | 137 | 3.59 | 362.6 | 1312.0 | 67 | 3.62 | 294.1 | 1079.0 | 54 | 3.67 | 104.6 | 276.0 | 14 | 2.64 | 80.2 | 118.0 | 6 | 1.47 | 61.3 | 206.0 | 16 | 3.36 | 186.7 | 674.0 | 33 | 3.61 | 474.0 | 1766.0 | 88 | 3.73 | 779.1 | 2843.0 | 143 | 3.65 | 1431.1 | 5013.0 | 264 | 3.50 | ||||||||||||
92 | Sole/Wasser | Vissmann Vitocal BWH113 | 16.2 | 2009 | 193 | 3 | 6107.0 | 20552.0 | 1089 | 3.37 | 1439.0 | 4588.0 | 240 | 3.19 | 992.0 | 3350.0 | 172 | 3.38 | 810.0 | 2869.0 | 147 | 3.54 | 283.0 | 959.0 | 47 | 3.39 | 165.0 | 551.0 | 28 | 3.34 | 124.0 | 384.0 | 64 | 3.10 | 81.0 | 157.0 | 8 | 1.94 | 63.0 | 119.0 | 6 | 1.89 | 109.0 | 347.0 | 17 | 3.18 | 440.0 | 1635.0 | 81 | 3.72 | 540.0 | 1948.0 | 94 | 3.61 | 1061.0 | 3645.0 | 185 | 3.44 | ||||||||||||
92 | Sole/Wasser | Vissmann Vitocal BWH113 | 16.2 | 2008 | 193 | 3 | 4006.0 | 12715.0 | 665 | 3.17 | 345.0 | 1098.0 | 65 | 3.18 | 207.0 | 451.0 | 37 | 2.18 | 134.0 | 317.0 | 16 | 2.37 | 102.0 | 305.0 | 15 | 2.99 | 127.0 | 268.0 | 13 | 2.11 | 335.0 | 1068.0 | 52 | 3.19 | 605.0 | 2038.0 | 102 | 3.37 | 914.0 | 3093.0 | 156 | 3.38 | 1237.0 | 4077.0 | 209 | 3.30 |
NR | 92 |
Username | Arko |
Einbaujahr der WP | 2008-03-07 |
PLZ des Wohnortes | 45149 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Vissmann Vitocal BWH113 |
modulierend | |
Leistung (0/35) | 16.2 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 3 Erdbohrungen a |
Tiefe | 95.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 3800 Watt DB |
elektr. Verbrauch HP gem./DB | 72 Watt |
elektr. Verbrauch WQ P gem./DB | 96 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 6.0 °C |
Heizung max. Vorlauf Temp. | 43.0 °C |
Spreizung Heizkr. | 4.6 |
Heizflaeche | 193 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | FBH im Wintergarten 16m²mit 1.1Verglasung, 34m²nur 15-18°Beheizt, Garage ca.3°, Wärmepumpe mit cooling 118m². |