Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 963 | Luft/Wasser | Fujitsu Waterstage WOYK160 | 16.0 | 2021 | 190 | 4 | 8031.0 | 21624.0 | 2.69 | 8031.0 | 21624.0 | 2.69 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 963 | Luft/Wasser | Fujitsu Waterstage WOYK160 | 16.0 | 2020 | 190 | 4 | 8809.0 | 23094.0 | 2.62 | 8809.0 | 23094.0 | 2.62 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 963 | Luft/Wasser | Fujitsu Waterstage WOYK160 | 16.0 | 2019 | 190 | 4 | 7384.0 | 22128.0 | 3.00 | 7384.0 | 22128.0 | 3.00 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 963 | Luft/Wasser | Fujitsu Waterstage WOYK160 | 16.0 | 2018 | 190 | 4 | 8235.0 | 23434.0 | 2.85 | 8235.0 | 23434.0 | 2.85 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 963 | Luft/Wasser | Fujitsu Waterstage WOYK160 | 16.0 | 2017 | 190 | 4 | 9325.0 | 25169.0 | 2.70 | 9325.0 | 25169.0 | 2.70 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 963 | Luft/Wasser | Fujitsu Waterstage WOYK160 | 16.0 | 2016 | 190 | 4 | 5317.0 | 15486.0 | 2007 | 2.91 | 1367.0 | 3647.0 | 509 | 2.67 | 1297.0 | 3677.0 | 499 | 2.84 | 1368.0 | 3773.0 | 521 | 2.76 | 940.0 | 3169.0 | 382 | 3.37 | 345.0 | 1220.0 | 96 | 3.54 | ||||||||||||||||||||||||||||||||||||||||
| 963 | Luft/Wasser | Fujitsu Waterstage WOYK160 | 16.0 | 2015 | 190 | 4 | 7702.0 | 23152.0 | 2464 | 3.01 | 1707.0 | 4407.0 | 509 | 2.58 | 1640.0 | 4256.0 | 554 | 2.60 | 1029.0 | 3291.0 | 3.20 | 700.0 | 2369.0 | 3.38 | 281.0 | 1157.0 | 151 | 4.12 | 592.0 | 2030.0 | 369 | 3.43 | 805.0 | 2571.0 | 395 | 3.19 | 948.0 | 3071.0 | 486 | 3.24 | ||||||||||||||||||||||||||||||
| 963 | Luft/Wasser | Fujitsu Waterstage WOYK160 | 16.0 | 2014 | 190 | 4 | 7018.0 | 20456.0 | 1294 | 2.91 | 1429.0 | 3676.0 | 2.57 | 1063.0 | 2980.0 | 2.80 | 920.0 | 2711.0 | 2.95 | 418.0 | 1377.0 | 3.29 | 344.0 | 1031.0 | 3.00 | 5 | 167.0 | 491.0 | 70 | 2.94 | 150.0 | 478.0 | 76 | 3.19 | 384.0 | 1341.0 | 238 | 3.49 | 724.0 | 2466.0 | 416 | 3.41 | 1419.0 | 3905.0 | 489 | 2.75 | ||||||||||||||||||||||||
| 963 | Luft/Wasser | Fujitsu Waterstage WOYK160 | 16.0 | 2013 | 190 | 4 | 10870.0 | 26841.0 | 2.47 | 2201.0 | 4407.0 | 2.00 | 2113.0 | 4494.0 | 2.13 | 1815.0 | 4312.0 | 2.38 | 812.0 | 2377.0 | 2.93 | 482.0 | 1539.0 | 3.19 | 113.0 | 356.0 | 3.15 | 6.0 | 20.0 | 3.33 | 258.0 | 840.0 | 3.26 | 553.0 | 1797.0 | 3.25 | 1167.0 | 3126.0 | 2.68 | 1350.0 | 3573.0 | 2.65 | ||||||||||||||||||||||||||||
| 963 | Luft/Wasser | Fujitsu Waterstage WOYK160 | 16.0 | 2012 | 190 | 4 | 3876.0 | 10044.0 | 2.59 | 268.0 | 917.0 | 3.42 | 684.0 | 2042.0 | 2.99 | 1159.0 | 3151.0 | 2.72 | 1765.0 | 3934.0 | 2.23 |
| NR | 963 |
| Username | Maddinsche |
| Einbaujahr der WP | 2012-08-15 |
| PLZ des Wohnortes | 51519 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Fujitsu Waterstage WOYK160 |
| modulierend | Ja |
| Leistung (0/35) | 16.0 kW |
| berechneter Primärenergiebedarf | 127.0 kWh/m²/anno |
| WW über WP | Nein |
| WW Temperatur | 0 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | Radiatoren |
| elektr. Verbrauch WP ohne NA gem./DB | 13 Watt gem. |
| elektr. Verbrauch HP gem./DB | 130 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | extern_geeicht |
| Mittlere Raumtemp. | 21.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 43.0 °C |
| Spreizung Heizkr. | 6.0 |
| Heizflaeche | 190 m² |
| Lüftung | Fenster |
| Personen | 4 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Heizölbedarf vorher ca. 2900 Liter, Vorlauftemperaturen: 10°C -> 35°C; -15°C->45°C - 16.02.13: Puffer in den Rücklauf. Strombedarf inkl. Pumpenstrom. Heizkurve: 0,80; Verschiebung: +4, Heizkörper mit Lüfter nachgerüstet. Betriebsstunden=Verdichter AN ab 2022: Heizkurve 0,90 |