Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
563 | Sole/Wasser | vaillant-geoThermplus 64/2 | 5.9 | 2014 | 95 | 1.5 | 761.0 | 2141.0* | 480 | 2.81 | 761.0 | 2036.0 | 480 | 2.81 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
563 | Sole/Wasser | vaillant-geoThermplus 64/2 | 5.9 | 2013 | 95 | 1.5 | 4785.0 | 13837.0* | 2051 | 2.89 | 764.0 | 2115.0 | 495 | 2.91 | 688.0 | 1917.0 | 449 | 2.94 | 1034.0 | 2851.0 | 2.86 | 141.0 | 368.0 | 3.35 | 105.0 | 195.0 | 2.86 | 91.0 | 14.0 | 3 | 1.31 | 113.0 | 94.0 | 1.76 | 202.0 | 427.0 | 2.63 | 355.0 | 1012.0 | 3.15 | 560.0 | 1625.0 | 642 | 3.09 | 732.0 | 2064.0 | 462 | 2.96 | ||||||||||||||||||||||
563 | Sole/Wasser | vaillant-geoThermplus 64/2 | 5.9 | 2012 | 95 | 1.5 | 4655.0 | 11959.0* | 1983 | 2.98 | 663.0 | 1896.0 | 432 | 3.02 | 721.0 | 1890.0 | 463 | 2.77 | 430.0 | 1229.0 | 273 | 3.10 | 356.0 | 1017.0 | 217 | 3.15 | 141.0 | 372.0 | 70 | 3.38 | 164.0 | 389.0 | 75 | 3.01 | 110.0 | 164.0 | 28 | 2.45 | 67.0 | 93.0 | 21 | 2.96 | 223.0 | 414.0 | 602.0 | 1760.0 | 3.10 | 764.0 | 2099.0 | 404 | 2.88 | |||||||||||||||||||
563 | Sole/Wasser | vaillant-geoThermplus 64/2 | 5.9 | 2011 | 95 | 1.5 | 3842.0 | 11766.0* | 1652 | 3.06 | 643.0 | 1651.0 | 324 | 2.73 | 569.0 | 1478.0 | 366 | 2.78 | 483.0 | 1353.0 | 3.02 | 255.0 | 737.0 | 3.30 | 151.0 | 388.0 | 3.26 | 81.0 | 152.0 | 3.17 | 97.0 | 163.0 | 30 | 2.76 | 70.0 | 145.0 | 3.57 | 112.0 | 295.0 | 52 | 3.57 | 299.0 | 909.0 | 178 | 3.39 | 470.0 | 1451.0 | 303 | 3.31 | 612.0 | 1784.0 | 399 | 3.09 | |||||||||||||||||
563 | Sole/Wasser | vaillant-geoThermplus 64/2 | 5.9 | 2010 | 95 | 1.5 | 4129.0 | 11722.0* | 268 | 2.84 | 670.0 | 1192.0 | 1.94 | 456.0 | 1140.0 | 268 | 2.73 | 407.0 | 1016.0 | 2.75 | 299.0 | 790.0 | 2.99 | 329.0 | 936.0 | 3.16 | 136.0 | 392.0 | 3.65 | 101.0 | 201.0 | 3.03 | 106.0 | 303.0 | 3.85 | 138.0 | 422.0 | 3.82 | 230.0 | 728.0 | 3.62 | 502.0 | 1463.0 | 3.12 | 755.0 | 1879.0 | 2.63 |
NR | 563 |
Username | frankklaus |
Einbaujahr der WP | 2009-08-21 |
PLZ des Wohnortes | 24351 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | vaillant-geoThermplus 64/2 |
modulierend | |
Leistung (0/35) | 5.9 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 50.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1400 Watt DB |
elektr. Verbrauch HP gem./DB | 123 Watt |
elektr. Verbrauch WQ P gem./DB | 93 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 4.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 4.0 |
Heizflaeche | 95 m² |
Lüftung | zenKWLWR |
Personen | 1,5 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Spreizung Heizkreise=hier habe ich dieDifferenz WW 45max 40min eingetragen=5k. unter WMZ habe ich die daten der Displayanzeige eingetragen=also nur quellen wärmeabgabe.Vorlauf ist 36 bei minus 8 grad aussen,34 bei +2grad. im März2011 Solartherme 10m2 + 40m2 mehr Fuss- bodenheizung eingebaut= nun 95m2 heizfläche. Dann die kurve auf 0,20 runtergesetzt,solltemp 26max 23min für HK6(abgabe ans haus über mischer), HK2 im sommer runter auf 22max 22min(das ist der 1000liter kessel).Also nur HK2 (abgabe an Kessel)zwischen 22(Sommer) und 27(Winter)grad verstellen,dann bleibt die Temperatur in allen Räumen konstant bei zu 80% geöffneten Ventilen. Endlich!!2011 etwa 10m2 solarpanele von vaillant zur unterstützung des 1000l kessels,heizt diesen bei sonne bis zu knapp 60grad auf. |