Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
770 | Luft/Wasser | Waterkotte - Ai1QL | 8.0 | 2015 | 210 | 2 | 6852.0 | 22886.0 | 3149 | 3.34 | 1385.0 | 4020.0 | 516 | 2.90 | 1390.0 | 3838.0 | 503 | 2.76 | 998.0 | 3531.0 | 493 | 3.54 | 691.0 | 2621.0 | 360 | 3.79 | 373.0 | 1530.0 | 210 | 4.10 | 148.0 | 472.0 | 58 | 3.19 | 90.0 | 183.0 | 17 | 2.03 | 83.0 | 152.0 | 15 | 1.83 | 315.0 | 1276.0 | 180 | 4.05 | 593.0 | 2418.0 | 363 | 4.08 | 786.0 | 2845.0 | 434 | 3.62 | ||||||||||||||||
770 | Luft/Wasser | Waterkotte - Ai1QL | 8.0 | 2014 | 210 | 2 | 6849.0 | 22782.0 | 3009 | 3.33 | 1289.0 | 3499.0 | 408 | 2.71 | 1140.0 | 3529.0 | 392 | 3.10 | 760.0 | 2835.0 | 421 | 3.73 | 457.0 | 1849.0 | 264 | 4.05 | 328.0 | 1298.0 | 179 | 3.96 | 101.0 | 227.0 | 36 | 2.25 | 91.0 | 181.0 | 17 | 1.99 | 104.0 | 250.0 | 29 | 2.40 | 236.0 | 911.0 | 121 | 3.86 | 432.0 | 1784.0 | 250 | 4.13 | 679.0 | 2614.0 | 381 | 3.85 | 1232.0 | 3805.0 | 511 | 3.09 | ||||||||||||
770 | Luft/Wasser | Waterkotte - Ai1QL | 8.0 | 2013 | 210 | 3 | 8241.0 | 24470.0 | 2756 | 2.97 | 1573.0 | 4012.0 | 447 | 2.55 | 1328.0 | 3446.0 | 351 | 2.59 | 1203.0 | 3513.0 | 389 | 2.92 | 552.0 | 1999.0 | 227 | 3.62 | 297.0 | 1117.0 | 126 | 3.76 | 196.0 | 681.0 | 126 | 3.47 | 92.0 | 195.0 | 22 | 2.12 | 85.0 | 155.0 | 20 | 1.82 | 265.0 | 1039.0 | 128 | 3.92 | 502.0 | 2003.0 | 234 | 3.99 | 801.0 | 2614.0 | 281 | 3.26 | 1347.0 | 3696.0 | 405 | 2.74 | ||||||||||||
770 | Luft/Wasser | Waterkotte - Ai1QL | 8.0 | 2012 | 210 | 3 | 8507.0 | 25808.0 | 2930 | 3.03 | 1315.0 | 4141.0 | 466 | 3.15 | 1766.0 | 4380.0 | 471 | 2.48 | 817.0 | 2880.0 | 327 | 3.53 | 601.0 | 2142.0 | 253 | 3.56 | 243.0 | 861.0 | 112 | 3.54 | 196.0 | 737.0 | 83 | 3.76 | 97.0 | 208.0 | 24 | 2.14 | 95.0 | 203.0 | 26 | 2.14 | 254.0 | 991.0 | 126 | 3.90 | 608.0 | 2216.0 | 261 | 3.64 | 807.0 | 2785.0 | 301 | 3.45 | 1708.0 | 4264.0 | 480 | 2.50 | ||||||||||||
770 | Luft/Wasser | Waterkotte - Ai1QL | 8.0 | 2011 | 210 | 3 | 1498.0 | 547 | 218.0 | 80 | 1280.0 | 467 |
NR | 770 |
Username | ABC |
Einbaujahr der WP | 2011-11-18 |
PLZ des Wohnortes | A-4076 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Waterkotte - Ai1QL |
modulierend | |
Leistung (0/35) | 8.0 kW |
berechneter Primärenergiebedarf | 141.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 200 Watt gem. |
elektr. Verbrauch HP gem./DB | 70 Watt |
elektr. Verbrauch WQ P gem./DB | 140 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 2.0 °C |
Heizung max. Vorlauf Temp. | 45.0 °C |
Spreizung Heizkr. | 7.0 |
Heizflaeche | 210 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Haus Bj. 1979 mit Vollwärmeschutz. 210m² mit FBH (Verlegeabstand ca. 20cm), in jedem Raum zusätzlich ein Heizkörper. FBH und Heizkörper werden mit der selben Temperatur gefahren. vorheriger Heizölverbrauch 2700L. 3fach Fenster ab 06/12 |