Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
866 | Sole/Wasser | Vaillant VWS 102/3 | 10.9 | 2018 | 282 | 4 | 2222.0 | 10228.7 | 786 | 4.60 | 487.2 | 2368.3 | 183 | 4.86 | 539.4 | 2576.0 | 203 | 4.78 | 503.6 | 2390.9 | 188 | 4.75 | 226.6 | 1036.6 | 79 | 4.57 | 108.2 | 439.2 | 32 | 4.06 | 80.3 | 303.5 | 22 | 3.78 | 68.0 | 234.8 | 17 | 3.45 | 107.1 | 451.3 | 32 | 4.21 | 101.6 | 428.1 | 30 | 4.21 | ||||||||||||||||||||||||
866 | Sole/Wasser | Vaillant VWS 102/3 | 10.9 | 2017 | 282 | 4 | 3066.3 | 14622.3 | 1108 | 4.77 | 557.5 | 2714.5 | 213 | 4.87 | 424.2 | 2080.2 | 162 | 4.90 | 320.3 | 1572.8 | 120 | 4.91 | 250.7 | 1236.8 | 92 | 4.93 | 136.5 | 595.0 | 45 | 4.36 | 67.6 | 238.6 | 17 | 3.53 | 60.6 | 205.5 | 14 | 3.39 | 67.7 | 238.1 | 17 | 3.52 | 145.8 | 662.0 | 47 | 4.54 | 204.3 | 969.1 | 70 | 4.74 | 379.0 | 1888.8 | 141 | 4.98 | 452.1 | 2220.9 | 170 | 4.91 | ||||||||||||
866 | Sole/Wasser | Vaillant VWS 102/3 | 10.9 | 2016 | 282 | 4 | 2971.8 | 14141.9 | 1068 | 4.76 | 477.5 | 2360.5 | 183 | 4.94 | 385.9 | 1920.9 | 146 | 4.98 | 354.3 | 1735.3 | 133 | 4.90 | 233.3 | 1128.3 | 84 | 4.84 | 122.3 | 508.2 | 37 | 4.16 | 72.2 | 255.6 | 19 | 3.54 | 72.4 | 252.5 | 18 | 3.49 | 76.6 | 278.2 | 20 | 3.63 | 71.0 | 260.0 | 18 | 3.66 | 228.7 | 1126.0 | 81 | 4.92 | 423.0 | 2079.4 | 158 | 4.92 | 454.6 | 2237.0 | 171 | 4.92 | ||||||||||||
866 | Sole/Wasser | Vaillant VWS 102/3 | 10.9 | 2015 | 282 | 4 | 2620.9 | 12436.7 | 931 | 4.75 | 440.5 | 2192.0 | 168 | 4.98 | 390.3 | 1923.8 | 148 | 4.93 | 315.4 | 1554.4 | 118 | 4.93 | 220.0 | 1043.9 | 79 | 4.75 | 145.1 | 643.2 | 47 | 4.43 | 89.9 | 342.8 | 25 | 3.81 | 71.1 | 249.2 | 18 | 3.50 | 66.7 | 227.9 | 16 | 3.42 | 107.9 | 450.6 | 32 | 4.18 | 213.0 | 1033.9 | 75 | 4.85 | 263.9 | 1302.8 | 96 | 4.94 | 297.1 | 1472.2 | 109 | 4.96 | ||||||||||||
866 | Sole/Wasser | Vaillant VWS 102/3 | 10.9 | 2014 | 282 | 4 | 3195.5 | 14104.7 | 1051 | 4.41 | 583.6 | 2632.7 | 204 | 4.51 | 438.1 | 1981.2 | 152 | 4.52 | 374.1 | 1665.8 | 125 | 4.45 | 244.2 | 1048.2 | 77 | 4.29 | 193.1 | 810.9 | 59 | 4.20 | 102.7 | 372.7 | 26 | 3.63 | 60.6 | 194.7 | 14 | 3.21 | 95.5 | 351.0 | 24 | 3.68 | 100.4 | 371.3 | 25 | 3.70 | 217.0 | 943.5 | 67 | 4.35 | 365.0 | 1654.3 | 121 | 4.53 | 421.2 | 2078.4 | 157 | 4.93 | ||||||||||||
866 | Sole/Wasser | Vaillant VWS 102/3 | 10.9 | 2013 | 282 | 4 | 3708.6 | 16697.9 | 1253 | 4.50 | 571.8 | 2700.0 | 209 | 4.72 | 518.8 | 2454.9 | 189 | 4.73 | 570.0 | 2644.0 | 204 | 4.64 | 332.3 | 1525.3 | 115 | 4.59 | 211.5 | 920.5 | 66 | 4.35 | 120.0 | 458.0 | 33 | 3.82 | 95.2 | 327.2 | 23 | 3.44 | 77.1 | 243.1 | 18 | 3.15 | 135.2 | 530.2 | 36 | 3.92 | 212.0 | 904.0 | 64 | 4.26 | 383.7 | 1782.7 | 130 | 4.65 | 481.0 | 2208.0 | 166 | 4.59 | ||||||||||||
866 | Sole/Wasser | Vaillant VWS 102/3 | 10.9 | 2012 | 282 | 4 | 2248.7 | 10115.9 | 803 | 4.50 | 331.7 | 1633.7 | 188 | 4.93 | 138.4 | 614.4 | 42 | 4.44 | 155.9 | 615.9 | 42 | 3.95 | 100.6 | 338.6 | 24 | 3.37 | 89.7 | 291.7 | 20 | 3.25 | 133.0 | 533.0 | 36 | 4.01 | 318.8 | 1476.8 | 105 | 4.63 | 409.4 | 1931.4 | 141 | 4.72 | 571.2 | 2680.4 | 205 | 4.69 |
NR | 866 |
Username | nommy |
Einbaujahr der WP | 2012-03-01 |
PLZ des Wohnortes | 27419 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Vaillant VWS 102/3 |
modulierend | |
Leistung (0/35) | 10.9 kW |
berechneter Primärenergiebedarf | 44.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 55 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 100.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt |
elektr. Verbrauch HP gem./DB | 44 Watt |
elektr. Verbrauch WQ P gem./DB | 114 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 7.0 °C |
Heizung max. Vorlauf Temp. | 33.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 282 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Seit Anfang Dez. 2014 wurde die ERR komplett deaktiviert und es wurde ein erneuter hydraulischer Abgleich durchgeführt. Heizkurve = 0,1 / Raumsolltemp = 23°C Die Verbräuche von HP und WQ P wurden nicht abgezogen. |