Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1421 | Luft/Wasser | Viessmann Vitocal 300A | 9.0 | 2022 | 134 | 3 | 656.0 | 2796.0 | 392 | 4.26 | 371.0 | 1596.0 | 223 | 4.30 | 285.0 | 1200.0 | 169 | 4.21 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
1421 | Luft/Wasser | Viessmann Vitocal 300A | 9.0 | 2021 | 134 | 3 | 2381.2 | 8849.6 | 1320 | 3.72 | 421.0 | 1408.0 | 256 | 3.34 | 385.0 | 943.8 | 241 | 2.45 | 279.0 | 1118.1 | 155 | 4.01 | 216.0 | 864.0 | 110 | 4.00 | 116.0 | 516.7 | 50 | 4.45 | 36.2 | 201.4 | 15 | 5.56 | 41.0 | 191.7 | 14 | 4.68 | 35.0 | 116.9 | 13 | 3.34 | 61.0 | 312.0 | 23 | 5.11 | 150.0 | 703.0 | 70 | 4.69 | 262.0 | 1223.0 | 136 | 4.67 | 379.0 | 1251.0 | 237 | 3.30 | ||||||||||||
1421 | Luft/Wasser | Viessmann Vitocal 300A | 9.0 | 2020 | 134 | 3 | 1813.0 | 7546.2 | 888 | 4.16 | 327.0 | 1333.0 | 175 | 4.08 | 221.0 | 964.0 | 113 | 4.36 | 249.0 | 1012.0 | 130 | 4.06 | 118.0 | 495.0 | 54 | 4.19 | 87.0 | 371.8 | 37 | 4.27 | 38.0 | 157.0 | 14 | 4.13 | 38.0 | 160.3 | 12 | 4.22 | 21.0 | 113.0 | 8 | 5.38 | 53.0 | 233.1 | 19 | 4.40 | 135.0 | 617.0 | 61 | 4.57 | 227.0 | 968.0 | 108 | 4.26 | 299.0 | 1122.0 | 157 | 3.75 | ||||||||||||
1421 | Luft/Wasser | Viessmann Vitocal 300A | 9.0 | 2019 | 134 | 3 | 1996.0 | 8835.8 | 1064 | 4.43 | 437.0 | 1655.0 | 275 | 3.79 | 307.0 | 1585.0 | 193 | 5.16 | 226.0 | 1119.0 | 115 | 4.95 | 138.0 | 605.0 | 65 | 4.38 | 102.0 | 483.0 | 45 | 4.74 | 34.0 | 151.2 | 11 | 4.45 | 18.0 | 75.0 | 6 | 4.17 | 26.0 | 119.0 | 9 | 4.58 | 50.0 | 236.6 | 19 | 4.73 | 123.0 | 558.0 | 56 | 4.54 | 237.0 | 1031.0 | 114 | 4.35 | 298.0 | 1218.0 | 156 | 4.09 | ||||||||||||
1421 | Luft/Wasser | Viessmann Vitocal 300A | 9.0 | 2018 | 134 | 3 | 2116.0 | 8773.3 | 1164 | 4.15 | 347.0 | 1428.0 | 182 | 4.12 | 417.0 | 1612.0 | 277 | 3.87 | 367.0 | 1370.0 | 221 | 3.73 | 114.0 | 496.0 | 52 | 4.35 | 49.0 | 205.7 | 14 | 4.20 | 30.0 | 142.0 | 15 | 4.73 | 29.0 | 124.3 | 9 | 4.29 | 21.0 | 86.5 | 7 | 4.12 | 50.0 | 211.6 | 20 | 4.23 | 148.0 | 658.0 | 67 | 4.45 | 251.0 | 1003.2 | 144 | 4.00 | 293.0 | 1436.0 | 156 | 4.90 | ||||||||||||
1421 | Luft/Wasser | Viessmann Vitocal 300A | 9.0 | 2017 | 134 | 4 | 2470.0 | 10530.6 | 1270 | 4.26 | 505.0 | 1768.8 | 300 | 3.50 | 408.0 | 1950.0 | 232 | 4.78 | 256.0 | 1165.0 | 122 | 4.55 | 225.0 | 1090.0 | 105 | 4.84 | 103.0 | 531.0 | 44 | 5.16 | 39.0 | 200.0 | 13 | 5.13 | 28.0 | 123.0 | 10 | 4.39 | 44.0 | 191.8 | 14 | 4.36 | 92.0 | 445.0 | 39 | 4.84 | 155.0 | 784.0 | 68 | 5.06 | 270.0 | 897.0 | 133 | 3.32 | 345.0 | 1385.0 | 190 | 4.01 | ||||||||||||
1421 | Luft/Wasser | Viessmann Vitocal 300A | 9.0 | 2016 | 134 | 4 | 2319.8 | 8911.6 | 1356 | 3.84 | 440.7 | 1253.0 | 257 | 2.84 | 304.0 | 1174.2 | 172 | 3.86 | 292.0 | 1324.0 | 171 | 4.53 | 206.0 | 799.0 | 99 | 3.88 | 78.0 | 348.0 | 133 | 4.46 | 38.7 | 207.7 | 16 | 5.37 | 27.0 | 116.0 | 10 | 4.30 | 41.3 | 220.6 | 17 | 5.34 | 35.1 | 184.8 | 15 | 5.26 | 184.0 | 813.5 | 86 | 4.42 | 298.0 | 1284.8 | 162 | 4.31 | 375.0 | 1186.0 | 218 | 3.16 | ||||||||||||
1421 | Luft/Wasser | Viessmann Vitocal 300A | 9.0 | 2015 | 134 | 4 | 2067.3 | 7817.2 | 1034 | 3.78 | 374.0 | 1520.0 | 202 | 4.06 | 306.0 | 1226.0 | 176 | 4.01 | 276.3 | 1155.0 | 140 | 4.18 | 177.4 | 738.1 | 92 | 4.16 | 62.6 | 260.9 | 22 | 4.17 | 63.8 | 244.5 | 22 | 3.83 | 38.8 | 200.0 | 15 | 5.15 | 37.9 | 146.7 | 12 | 3.87 | 65.0 | 273.7 | 24 | 4.21 | 179.3 | 351.1 | 87 | 1.96 | 223.0 | 906.0 | 109 | 4.06 | 263.2 | 795.2 | 133 | 3.02 | ||||||||||||
1421 | Luft/Wasser | Viessmann Vitocal 300A | 9.0 | 2014 | 134 | 4 | 2023.5 | 8241.4 | 1184 | 4.07 | 467.0 | 1467.0 | 319 | 3.14 | 262.0 | 1368.0 | 154 | 5.22 | 201.0 | 802.0 | 94 | 3.99 | 101.0 | 421.0 | 44 | 4.17 | 84.0 | 385.0 | 35 | 4.58 | 55.0 | 223.0 | 20 | 4.05 | 45.0 | 208.0 | 16 | 4.62 | 36.0 | 156.0 | 12 | 4.33 | 55.0 | 215.1 | 19 | 3.91 | 103.0 | 461.0 | 41 | 4.48 | 234.9 | 1004.7 | 113 | 4.28 | 379.6 | 1530.6 | 317 | 4.03 | ||||||||||||
1421 | Luft/Wasser | Viessmann Vitocal 300A | 9.0 | 2013 | 134 | 4 | 687.0 | 2670.0 | 399 | 3.89 | 350.0 | 1440.0 | 225 | 4.11 | 337.0 | 1230.0 | 174 | 3.65 |
NR | 1421 |
Username | fdhallo |
Einbaujahr der WP | 2014-09-15 |
PLZ des Wohnortes | 04288 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Viessmann Vitocal 300A |
modulierend | Ja |
Leistung (0/35) | 9.0 kW |
berechneter Primärenergiebedarf | 57.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 47 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2100 Watt DB |
elektr. Verbrauch HP gem./DB | 60 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 4.0 |
Heizflaeche | 134 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |