Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2301 | Luft/Wasser | Tecalor THZ504 | 10.0 | 2022 | 167 | 4 | 2111.0 | 6162.0 | 2.92 | 476.0 | 1847.0 | 3.88 | 388.0 | 1518.0 | 3.91 | 349.0 | 1155.0 | 3.31 | 262.0 | 857.0 | 3.27 | 147.0 | 268.0 | 1.82 | 129.0 | 129.0 | 1.00 | 105.0 | 57.0 | 0.54 | 135.0 | 62.0 | 0.46 | 96.0 | 180.0 | 1.88 | 24.0 | 89.0 | 3.71 | |||||||||||||||||||||||||||||||
2301 | Luft/Wasser | Tecalor THZ504 | 10.0 | 2021 | 167 | 4 | 3667.4 | 9699.0 | 3.13 | 602.0 | 2161.0 | 3.59 | 560.0 | 1643.0 | 2.93 | 381.0 | 1511.0 | 3.97 | 318.6 | 203.4 | 681.0 | 3.35 | 148.0 | 124.0 | 0.84 | 95.3 | 99.0 | 1.04 | 123.6 | 126.0 | 1.02 | 111.6 | 155.0 | 1.39 | 247.9 | 364.0 | 1302.0 | 3.58 | 512.0 | 1897.0 | 3.71 | |||||||||||||||||||||||||||||
2301 | Luft/Wasser | Tecalor THZ504 | 10.0 | 2020 | 167 | 4 | 2581.8 | 6826.0 | 2.64 | 507.7 | 647.0 | 1.27 | 453.4 | 1648.0 | 3.63 | 461.3 | 1608.0 | 3.49 | 251.5 | 708.0 | 2.82 | 217.5 | 570.0 | 2.62 | 105.1 | 166.0 | 1.58 | 121.8 | 236.0 | 1.94 | 137.9 | 132.0 | 0.96 | 133.1 | 183.0 | 1.37 | 13.5 | 20.0 | 1.48 | 179.0 | 908.0 | 5.07 | ||||||||||||||||||||||||||||
2301 | Luft/Wasser | Tecalor THZ504 | 10.0 | 2019 | 167 | 4 | 3787.5 | 13122.0 | 3.46 | 793.7 | 3494.0 | 4.40 | 482.0 | 1783.0 | 3.70 | 436.1 | 1679.0 | 3.85 | 317.6 | 1098.0 | 3.46 | 206.2 | 565.0 | 2.74 | 85.6 | 120.0 | 1.40 | 108.2 | 143.0 | 1.32 | 92.1 | 107.0 | 1.16 | 139.5 | 237.0 | 1.70 | 240.1 | 713.0 | 2.97 | 402.0 | 1459.0 | 3.63 | 484.4 | 1724.0 | 3.56 | |||||||||||||||||||||||||
2301 | Luft/Wasser | Tecalor THZ504 | 10.0 | 2018 | 167 | 4 | 1988.4 | 560.0 | 267.0 | 545.0 | 616.4 |
NR | 2301 |
Username | selfisch |
Einbaujahr der WP | 2018-10-01 |
PLZ des Wohnortes | 49134 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Tecalor THZ504 |
modulierend | Ja |
Leistung (0/35) | 10.0 kW |
berechneter Primärenergiebedarf | 55.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 40.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 167 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Zu Beginn im September 2018 ist ein FBH Aufheizprogramm mit drin. |