| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3057 | Luft/Wasser | Panasonic Aquarea KIT-WC07J3E5 | 7.0 | 2025 | 96 | 4 | 2222.7 | 10578.1 | 4.76 | 430.4 | 1930.0 | 4.48 | 384.2 | 1720.0 | 4.48 | 296.1 | 1420.0 | 4.80 | 137.0 | 726.0 | 5.30 | 91.6 | 482.0 | 5.26 | 42.0 | 167.0 | 3.98 | 36.2 | 134.0 | 3.70 | 46.8 | 185.0 | 3.95 | 55.0 | 61.1 | 1.11 | 140.0 | 523.0 | 3.74 | 250.0 | 1730.0 | 6.92 | 313.4 | 1500.0 | 4.79 | |||||||||||||||||||||||||
| 3057 | Luft/Wasser | Panasonic Aquarea KIT-WC07J3E5 | 7.0 | 2024 | 96 | 4 | 2010.1 | 10211.0 | 5.08 | 473.4 | 2120.0 | 4.48 | 263.5 | 1450.0 | 5.50 | 209.4 | 1170.0 | 5.59 | 167.7 | 959.0 | 5.72 | 56.1 | 256.0 | 4.56 | 38.1 | 175.0 | 4.59 | 44.6 | 171.0 | 3.83 | 36.8 | 134.0 | 3.64 | 53.4 | 244.0 | 4.57 | 111.2 | 652.0 | 5.86 | 243.7 | 1270.0 | 5.21 | 312.2 | 1610.0 | 5.16 | |||||||||||||||||||||||||
| 3057 | Luft/Wasser | Panasonic Aquarea KIT-WC07J3E5 | 7.0 | 2023 | 96 | 3 | 1386.1 | 7032.0 | 2166 | 5.07 | 334.9 | 1750.0 | 589 | 5.23 | 311.0 | 1580.0 | 529 | 5.08 | 283.8 | 1470.0 | 469 | 5.18 | 200.7 | 1090.0 | 322 | 5.43 | 104.1 | 537.0 | 140 | 5.16 | 37.4 | 144.0 | 32 | 3.85 | 43.7 | 173.0 | 32 | 3.96 | 37.5 | 144.0 | 26 | 3.84 | 33.0 | 144.0 | 27 | 4.36 | ||||||||||||||||||||||||
| 3057 | Luft/Wasser | Panasonic Aquarea KIT-WC07J3E5 | 7.0 | 2022 | 96 | 3 | 1045.7 | 5349.0 | 1405 | 5.12 | 16.8 | 74.0 | 15 | 4.40 | 29.4 | 111.0 | 20 | 3.78 | 68.5 | 420.0 | 6.13 | 103.0 | 664.0 | 160 | 6.45 | 390.1 | 2090.0 | 586 | 5.36 | 437.9 | 1990.0 | 624 | 4.54 |
| NR | 3057 |
| Username | Hypo93 |
| Einbaujahr der WP | 2022-07-16 |
| PLZ des Wohnortes | 21077 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Panasonic Aquarea KIT-WC07J3E5 |
| modulierend | Ja |
| Leistung (0/35) | 7.0 kW |
| berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 46 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH und Radiatoren |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | extern_geeicht |
| Mittlere Raumtemp. | 21.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 0.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 96 m² |
| Lüftung | Fenster |
| Personen | 3 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Freistehendes EFH Bj. 1938, Anbau Bj. 1956 - WDVS System U-Wert 0,24 Altbau, 0,20 Anbau - Dachaufbau U-Wert 0,24 - Keller 0,30 - 8,855kWp Photovoltaik -10 Grad Süd / DN 57° - 4,62 kWp PV auf dem Garagendach -10 Grad Süd / DN 4 |