Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
794 | Luft/Wasser | Rotex HPSU Compact | 8.0 | 2023 | 142 | 2 | 2559.0 | 10569.0 | 4.13 | 440.0 | 1137.0 | 2.58 | 445.0 | 909.0 | 2.04 | 433.0 | 987.0 | 2.28 | 299.0 | 976.0 | 3.26 | 138.0 | 584.0 | 4.23 | 46.0 | 139.0 | 3.02 | 34.0 | 93.0 | 2.74 | 48.0 | 134.0 | 2.79 | 76.0 | 291.0 | 3.83 | 219.0 | 1642.0 | 7.50 | 381.0 | 3677.0 | 9.65 | ||||||||||||||||||||||||||||
794 | Luft/Wasser | Rotex HPSU Compact | 8.0 | 2022 | 142 | 2 | 3121.0 | 7784.0 | 2.49 | 478.0 | 1387.0 | 2.90 | 380.0 | 1133.0 | 2.98 | 474.0 | 1232.0 | 2.60 | 286.0 | 778.0 | 2.72 | 112.0 | 339.0 | 3.03 | 41.0 | 119.0 | 2.90 | 32.0 | 86.0 | 2.69 | 32.0 | 80.0 | 2.50 | 125.0 | 548.0 | 4.38 | 172.0 | 281.0 | 1.63 | 399.0 | 907.0 | 2.27 | 590.0 | 894.0 | 1.52 | |||||||||||||||||||||||||
794 | Luft/Wasser | Rotex HPSU Compact | 8.0 | 2021 | 142 | 2 | 3726.0 | 11351.0 | 3.05 | 612.0 | 1672.0 | 2.73 | 579.0 | 1565.0 | 2.70 | 426.0 | 1377.0 | 3.23 | 335.0 | 1166.0 | 3.48 | 193.0 | 740.0 | 3.83 | 32.0 | 101.0 | 3.16 | 43.0 | 126.0 | 2.93 | 82.0 | 296.0 | 3.61 | 124.0 | 371.0 | 2.99 | 294.0 | 1073.0 | 3.65 | 401.0 | 1278.0 | 3.19 | 605.0 | 1586.0 | 2.62 | |||||||||||||||||||||||||
794 | Luft/Wasser | Rotex HPSU Compact | 8.0 | 2020 | 142 | 2 | 3167.0 | 9830.0 | 3.10 | 485.0 | 1241.0 | 2.56 | 393.0 | 1033.0 | 2.63 | 438.0 | 1315.0 | 3.00 | 283.0 | 819.0 | 2.89 | 176.0 | 685.0 | 3.89 | 63.0 | 239.0 | 3.79 | 60.0 | 237.0 | 3.95 | 53.0 | 194.0 | 3.66 | 137.0 | 551.0 | 4.02 | 234.0 | 868.0 | 3.71 | 334.0 | 1137.0 | 3.40 | 511.0 | 1511.0 | 2.96 | |||||||||||||||||||||||||
794 | Luft/Wasser | Rotex HPSU Compact | 8.0 | 2019 | 142 | 2 | 3548.0 | 9874.0 | 2.78 | 591.0 | 1671.0 | 2.83 | 448.0 | 1375.0 | 3.07 | 332.0 | 1046.0 | 3.15 | 298.0 | 824.0 | 2.77 | 239.0 | 602.0 | 2.52 | 75.0 | 86.0 | 1.15 | 76.0 | 150.0 | 1.97 | 91.0 | 121.0 | 1.33 | 294.0 | 633.0 | 2.15 | 255.0 | 677.0 | 2.65 | 345.0 | 1164.0 | 3.37 | 504.0 | 1525.0 | 3.03 | |||||||||||||||||||||||||
794 | Luft/Wasser | Rotex HPSU Compact | 8.0 | 2018 | 142 | 2 | 3599.0 | 9506.0 | 2.64 | 513.0 | 1173.0 | 2.29 | 627.0 | 1198.0 | 1.91 | 613.0 | 1233.0 | 2.01 | 204.0 | 529.0 | 2.59 | 110.0 | 257.0 | 2.34 | 67.0 | 212.0 | 3.16 | 60.0 | 190.0 | 3.17 | 59.0 | 220.0 | 3.73 | 127.0 | 379.0 | 2.98 | 295.0 | 1167.0 | 3.96 | 542.0 | 1455.0 | 2.68 | 382.0 | 1493.0 | 3.91 | |||||||||||||||||||||||||
794 | Luft/Wasser | Rotex HPSU Compact | 8.0 | 2017 | 142 | 3 | 3485.0 | 7578.0 | 2.17 | 652.0 | 824.0 | 1.26 | 460.0 | 552.0 | 1.20 | 376.0 | 434.0 | 1.15 | 308.0 | 477.0 | 1.55 | 159.0 | 591.0 | 3.72 | 74.0 | 337.0 | 4.55 | 75.0 | 324.0 | 4.32 | 88.0 | 318.0 | 3.61 | 174.0 | 637.0 | 3.66 | 251.0 | 843.0 | 3.36 | 363.0 | 1057.0 | 2.91 | 505.0 | 1184.0 | 2.34 | |||||||||||||||||||||||||
794 | Luft/Wasser | Rotex HPSU Compact | 8.0 | 2016 | 142 | 3 | 3506.0 | 6305.0 | 1.80 | 687.0 | 1044.0 | 1.52 | 440.0 | 859.0 | 1.95 | 445.0 | 889.0 | 2.00 | 280.0 | 575.0 | 2.05 | 129.0 | 256.0 | 1.98 | 51.0 | 114.0 | 2.24 | 67.0 | 87.0 | 1.30 | 78.0 | 137.0 | 1.76 | 114.0 | 247.0 | 2.17 | 256.0 | 506.0 | 1.98 | 446.0 | 759.0 | 1.70 | 513.0 | 832.0 | 1.62 | |||||||||||||||||||||||||
794 | Luft/Wasser | Rotex HPSU Compact | 8.0 | 2015 | 142 | 3 | 3194.0 | 5393.0 | 1.69 | 494.0 | 518.0 | 1.05 | 504.0 | 673.0 | 1.34 | 394.0 | 686.0 | 1.74 | 276.0 | 507.0 | 1.84 | 174.0 | 336.0 | 1.93 | 97.0 | 180.0 | 1.86 | 55.0 | 81.0 | 1.47 | 59.0 | 75.0 | 1.27 | 137.0 | 374.0 | 2.73 | 325.0 | 608.0 | 1.87 | 333.0 | 657.0 | 1.97 | 346.0 | 698.0 | 2.02 | |||||||||||||||||||||||||
794 | Luft/Wasser | Rotex HPSU Compact | 8.0 | 2014 | 142 | 3 | 3184.0 | 5077.0 | 1.59 | 627.0 | 934.0 | 1.49 | 397.0 | 628.0 | 1.58 | 354.0 | 526.0 | 1.49 | 188.0 | 311.0 | 1.65 | 175.0 | 253.0 | 1.45 | 88.0 | 118.0 | 1.34 | 56.0 | 65.0 | 1.16 | 93.0 | 164.0 | 1.76 | 128.0 | 254.0 | 1.98 | 220.0 | 439.0 | 2.00 | 341.0 | 591.0 | 1.73 | 517.0 | 794.0 | 1.54 | |||||||||||||||||||||||||
794 | Luft/Wasser | Rotex HPSU Compact | 8.0 | 2013 | 142 | 3 | 3823.0 | 7916.0 | 2.07 | 740.0 | 1759.0 | 2.38 | 622.0 | 1094.0 | 1.76 | 700.0 | 1578.0 | 2.25 | 294.0 | 643.0 | 2.19 | 141.0 | 350.0 | 2.48 | 72.0 | 142.0 | 1.97 | 45.0 | 57.0 | 1.27 | 57.0 | 88.0 | 1.54 | 149.0 | 376.0 | 2.52 | 212.0 | 385.0 | 1.82 | 331.0 | 651.0 | 1.97 | 460.0 | 793.0 | 1.72 | |||||||||||||||||||||||||
794 | Luft/Wasser | Rotex HPSU Compact | 8.0 | 2012 | 142 | 3 | 4585.0 | 11909.0 | 4.25 | 556.0 | 1227.0 | 472.0 | 1956.0 | 4.14 | 392.0 | 1692.0 | 4.32 | 165.0 | 901.0 | 5.46 | 107.0 | 641.0 | 5.99 | 89.0 | 490.0 | 5.51 | 90.0 | 488.0 | 5.42 | 124.0 | 703.0 | 5.67 | 296.0 | 1369.0 | 4.63 | 406.0 | 1598.0 | 3.94 | 661.0 | 2071.0 | 3.13 |
NR | 794 |
Username | spekulant110 |
Einbaujahr der WP | 2011-11-10 |
PLZ des Wohnortes | 14558 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Rotex HPSU Compact |
modulierend | Ja |
Leistung (0/35) | 8.0 kW |
berechneter Primärenergiebedarf | 75.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: |
WMZ | intern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 142 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Erste Reparatur im Mai 2017, Fehler 7H (Durchflussmengensensor). Kosten ca. 200€. Seit Ende 2023 scheint der eingebaute Wärmemengenzähler der Rotex nicht mehr korrekt zu zählen, die Werte sind sehr hoch und nicht plausibel. |