Verbrauchsdaten fuer Anlage Nr. 115
| Jahr | Pers. | GESAMT | Jan | Feb | Mar | Apr | Mai | Jun | Jul | Aug | Sep | Okt | Nov | Dez | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | ||
| 2023 | 4 | 2747 | 11101 | 4.04 | 521 | 2214 | 4.25 | 421 | 1735 | 4.12 | 326 | 1252 | 3.84 | 278 | 1106 | 3.98 | 76 | 228 | 3.00 | 16 | 39 | 2.44 | 0 | 0 | 0 | 0 | 45 | 190 | 4.22 | 162 | 565 | 3.49 | 446 | 1874 | 4.20 | 456 | 1898 | 4.16 | ||
| 2022 | 4 | 2388 | 8862 | 3.71 | 533 | 2213 | 4.15 | 338 | 1287 | 3.81 | 321 | 1167 | 3.64 | 227 | 739 | 3.26 | 0 | 0 | 0 | 0 | 0 | 0 | 59 | 0 | 69 | 77 | 1.12 | 38 | 52 | 1.37 | 310 | 1206 | 3.89 | 493 | 2121 | 4.30 | ||||
| 2021 | 4 | 2657 | 11099 | 4.18 | 443 | 1909 | 4.31 | 444 | 1910 | 4.30 | 336 | 1326 | 3.95 | 274 | 1080 | 3.94 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 101 | 289 | 2.86 | 174 | 684 | 3.93 | 402 | 1807 | 4.50 | 483 | 2094 | 4.34 | ||||
| 2020 | 4 | 2440 | 9632 | 3.95 | 514 | 2138 | 4.16 | 369 | 1534 | 4.16 | 286 | 1102 | 3.85 | 78 | 154 | 1.97 | 76 | 146 | 1.92 | 0 | 0 | 0 | 0 | 0 | 0 | 97 | 123 | 1.27 | 221 | 906 | 4.10 | 293 | 1323 | 4.52 | 506 | 2206 | 4.36 | |||
| 2019 | 4 | 2689 | 10803 | 4.02 | 720 | 3105 | 4.31 | 319 | 1284 | 4.03 | 295 | 1121 | 3.80 | 115 | 415 | 3.61 | 113 | 332 | 2.94 | 0 | 0 | 0 | 0 | 0 | 0 | 80 | 133 | 1.66 | 171 | 657 | 3.84 | 440 | 1897 | 4.31 | 436 | 1859 | 4.26 | |||
| 2018 | 4 | 3479 | 14509 | 4.17 | 489 | 2093 | 4.28 | 531 | 2232 | 4.20 | 518 | 2177 | 4.20 | 353 | 1370 | 3.88 | 0 | 0 | 0 | 0 | 0 | 0 | 140 | 450 | 3.21 | 340 | 1400 | 4.12 | 669 | 2872 | 4.29 | 439 | 1915 | 4.36 | ||||||
| 2017 | 4 | 2777 | 12828 | 4.62 | 522 | 2773 | 5.31 | 703 | 3491 | 4.97 | 394 | 1945 | 4.94 | 253 | 1067 | 4.22 | 173 | 803 | 4.64 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 148 | 428 | 2.89 | 147 | 472 | 3.21 | 437 | 1849 | 4.23 | ||||
| 2016 | 4 | 2701 | 12151 | 4.50 | 605 | 2972 | 4.91 | 318 | 1584 | 4.98 | 299 | 1407 | 4.71 | 186 | 808 | 4.34 | 61 | 197 | 3.23 | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 10 | 1.00 | 273 | 982 | 3.60 | 427 | 1912 | 4.48 | 522 | 2279 | 4.37 | |||
| 2014 | 4 | 1682 | 7888 | 4.69 | 481 | 2425 | 5.05 | 440 | 1976 | 4.49 | 152 | 580 | 3.83 | 113 | 491 | 4.35 | 147 | 752 | 5.12 | 350 | 1664 | 4.75 | ||||||||||||||||||
| 2013 | 4 | 0 | 0 | |||||||||||||||||||||||||||||||||||||
| 2012 | 4 | 2340 | 9928 | 4.24 | 513 | 2280 | 4.44 | 601 | 2556 | 4.25 | 242 | 873 | 3.61 | 229 | 925 | 4.05 | 24 | 53 | 2.17 | 0 | 0 | 0 | 0 | 0 | 0 | 23 | 59 | 2.57 | 272 | 1111 | 4.09 | 436 | 2070 | 4.75 | ||||||
| 2011 | 3 | 2600 | 10507 | 4.04 | 619 | 2636 | 4.26 | 452 | 1877 | 4.15 | 333 | 1136 | 3.41 | 83 | 228 | 2.75 | 23 | 24 | 1.04 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 180 | 646 | 3.59 | 439 | 1841 | 4.19 | 471 | 2119 | 4.50 | ||||
| 2010 | 3 | 3424 | 13345 | 3.90 | 859 | 2946 | 3.43 | 468 | 1786 | 3.82 | 345 | 1418 | 4.11 | 164 | 660 | 4.02 | 140 | 512 | 3.66 | 25 | 121 | 4.84 | 0 | 0 | 0 | 0 | 94 | 332 | 3.53 | 276 | 1159 | 4.20 | 375 | 1568 | 4.18 | 678 | 2843 | 4.19 | ||
Vollständige Anlagendetails
Allgemeine Daten
Anlagen Nr.
115
Username
Teckbau
Gebäude Daten
PLZ
73265
Heizfläche (m²)
180
Wärmeübertragung
FBH
Raumtemperatur (°C)
23.0
Lüftung
Fenster
Endenergiebedarf (kWh/m²/anno)
53.0
berechnet nach Norm
EnEV2007
Wärmepumpe Daten
Hersteller / Typ
Junkers Supraeco STE 90
Bauart
Sole/Wasser
Heizleistung (kW) (0/35 2/35)
9.2
Betriebsart Mono/Bi/Tri-valent
Bi
Modulierend
Nein
Einbaudatum
2009-11-01
Wärmepumpe Leistungsaufnahme (W)
Umwälzpumpe Leistungsaufnahme (W)
Wärme Quelle & Senke
Quelle
1 Erdbohrung
Tiefe (m)
140.0
Fläche (m²)
max. Vorlauftemperatur (°C)
35.0
Spreizung Heizkreise (°K)
8.0
Quellenpumpe Leistungsaufnahme (W)
RGK Helfer
Nein
RGK Erfahrung
Warmwasser
über WP erzeugt
teil
über WMZ erfasst
Ja
Temp (°C)
50
Legionellenschaltung
Nein
Zähler
Stromzähler
intern
Stromzähler erfasst
Kompressor,Steuerung,Pumpen
Wärmemengenzähler
intern
Informationen
Bemerkungen
Es gibt noch eine 10m² Solarthermie für Heizungsunterstützung. Deswegen sind die Verbrauchswerte im Sommer und in den Übergangszeiten mit Vorsicht zu genießen.
Links