Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1379 | Sole/Wasser | Vaillant GeoTherm VWS 81/3 | 7.4 | 2015 | 220 | 4 | 2888.0 | 9989.0 | 1439 | 3.46 | 501.0 | 1721.0 | 261 | 3.44 | 496.0 | 1636.0 | 266 | 3.30 | 399.0 | 1328.0 | 209 | 3.33 | 247.0 | 821.0 | 126 | 3.32 | 83.0 | 249.0 | 36 | 3.00 | 50.0 | 138.0 | 19 | 2.76 | 48.0 | 137.0 | 17 | 2.85 | 42.0 | 128.0 | 16 | 3.05 | 87.0 | 326.0 | 36 | 3.75 | 255.0 | 992.0 | 116 | 3.89 | 317.0 | 1195.0 | 155 | 3.77 | 363.0 | 1318.0 | 182 | 3.63 | ||||||||||||
1379 | Sole/Wasser | Vaillant GeoTherm VWS 81/3 | 7.4 | 2014 | 220 | 4 | 2646.0 | 9243.0 | 1306 | 3.49 | 491.0 | 1684.0 | 259 | 3.43 | 415.0 | 1375.0 | 216 | 3.31 | 333.0 | 1099.0 | 170 | 3.30 | 141.0 | 462.0 | 66 | 3.28 | 88.0 | 285.0 | 39 | 3.24 | 35.0 | 95.0 | 12 | 2.71 | 43.0 | 131.0 | 16 | 3.05 | 36.0 | 107.0 | 13 | 2.97 | 97.0 | 364.0 | 40 | 3.75 | 165.0 | 639.0 | 72 | 3.87 | 371.0 | 1438.0 | 180 | 3.88 | 431.0 | 1564.0 | 223 | 3.63 | ||||||||||||
1379 | Sole/Wasser | Vaillant GeoTherm VWS 81/3 | 7.4 | 2013 | 220 | 4 | 3369.0 | 11298.0 | 1719 | 3.35 | 607.0 | 2020.0 | 324 | 3.33 | 586.0 | 1877.0 | 312 | 3.20 | 566.0 | 1780.0 | 299 | 3.14 | 342.0 | 1060.0 | 175 | 3.10 | 160.0 | 530.0 | 77 | 3.31 | 78.0 | 237.0 | 33 | 3.04 | 43.0 | 120.0 | 16 | 2.79 | 23.0 | 67.0 | 8 | 2.91 | 41.0 | 122.0 | 15 | 2.98 | 151.0 | 598.0 | 69 | 3.96 | 334.0 | 1304.0 | 166 | 3.90 | 438.0 | 1583.0 | 225 | 3.61 | ||||||||||||
1379 | Sole/Wasser | Vaillant GeoTherm VWS 81/3 | 7.4 | 2012 | 220 | 4 | 3181.0 | 10789.0 | 1639 | 3.39 | 728.0 | 2042.0 | 300 | 2.80 | 654.0 | 2137.0 | 376 | 3.27 | 333.0 | 1129.0 | 192 | 3.39 | 163.0 | 832.0 | 135 | 5.10 | 79.0 | 229.0 | 34 | 2.90 | 35.0 | 102.0 | 13 | 2.91 | 1.0 | 0 | 0 | 2.0 | 8.0 | 1 | 4.00 | 41.0 | 129.0 | 15 | 3.15 | 259.0 | 1023.0 | 119 | 3.95 | 395.0 | 1482.0 | 197 | 3.75 | 491.0 | 1676.0 | 257 | 3.41 |
NR | 1379 |
Username | BerniTDT |
Einbaujahr der WP | 2011-11-22 |
PLZ des Wohnortes | 90587 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Vaillant GeoTherm VWS 81/3 |
modulierend | |
Leistung (0/35) | 7.4 kW |
berechneter Primärenergiebedarf | 15.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 55 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 1.7 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1500 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 1.0 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 220 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Sparsamer Grabenkollektor mit 35 m Slinkyverlegung und 40 m gerader Verlegung, 2x Rohre á 300 m Länge. Anlage mit Pufferspeicher Zeeh MTLS WP 850, deshalb verringerte Arbeitszahl da immer 5° mehr Temperaturniveau zur Ladung benötigt wird. Warmwasserbereitung im Durchlaufsystem. |