Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2024 | 280 | 2+Pra | 3019.0 | 15884.0 | 5.26 | 682.0 | 3576.0 | 5.24 | 590.0 | 3140.0 | 5.32 | 652.0 | 3449.0 | 5.29 | 447.0 | 2374.0 | 5.31 | 375.0 | 1952.0 | 5.21 | 157.0 | 833.0 | 5.31 | 83.0 | 430.0 | 5.18 | 33.0 | 130.0 | 3.94 | |||||||||||||||||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2023 | 280 | 2+Praxis | 4938.0 | 26746.0 | 5.42 | 732.0 | 3940.0 | 5.38 | 677.0 | 3662.0 | 5.41 | 590.0 | 3228.0 | 5.47 | 550.0 | 3025.0 | 5.50 | 350.0 | 1911.0 | 5.46 | 67.0 | 334.0 | 4.99 | 102.0 | 522.0 | 5.12 | 77.0 | 414.0 | 5.38 | 141.0 | 768.0 | 5.45 | 340.0 | 1887.0 | 5.55 | 614.0 | 3333.0 | 5.43 | 698.0 | 3722.0 | 5.33 | |||||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2022 | 280 | 2+Praxis | 5175.0 | 26857.0 | 5.19 | 800.0 | 4107.0 | 5.13 | 697.0 | 3559.0 | 5.11 | 661.0 | 3379.0 | 5.11 | 529.0 | 2687.0 | 5.08 | 334.0 | 1714.0 | 5.13 | 131.0 | 630.0 | 4.81 | 90.0 | 402.0 | 4.47 | 91.0 | 409.0 | 4.49 | 239.0 | 1230.0 | 5.15 | 336.0 | 1865.0 | 5.55 | 492.0 | 2750.0 | 5.59 | 775.0 | 4125.0 | 5.32 | |||||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2021 | 280 | 3+Praxis | 5760.0 | 29744.0 | 5.16 | 742.0 | 3776.0 | 5.09 | 656.0 | 3320.0 | 5.06 | 673.0 | 3453.0 | 5.13 | 641.0 | 3311.0 | 5.17 | 433.0 | 2295.0 | 5.30 | 124.0 | 568.0 | 4.58 | 114.0 | 521.0 | 4.57 | 210.0 | 935.0 | 4.45 | 251.0 | 1330.0 | 5.30 | 486.0 | 2653.0 | 5.46 | 528.0 | 2755.0 | 5.22 | 902.0 | 4827.0 | 5.35 | |||||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2020 | 280 | 3+Praxis | 5063.0 | 26412.0 | 2048 | 5.22 | 706.0 | 3786.0 | 5.36 | 724.0 | 3867.0 | 5.34 | 643.0 | 3358.0 | 5.22 | 354.0 | 1820.0 | 5.14 | 362.0 | 1889.0 | 5.22 | 197.0 | 994.0 | 5.05 | 102.0 | 467.0 | 4.58 | 105.0 | 470.0 | 4.48 | 203.0 | 1035.0 | 5.10 | 374.0 | 1991.0 | 5.32 | 526.0 | 2753.0 | 5.23 | 767.0 | 3982.0 | 2048 | 5.19 | |||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2019 | 280 | 3+Praxis | 4607.0 | 25325.0 | 5.50 | 640.0 | 3423.0 | 5.35 | 630.0 | 3390.0 | 5.38 | 603.0 | 3296.0 | 5.47 | 457.0 | 2539.0 | 5.56 | 372.0 | 2094.0 | 5.63 | 119.0 | 645.0 | 5.42 | 60.0 | 270.0 | 4.50 | 122.0 | 680.0 | 5.57 | 220.0 | 1283.0 | 5.83 | 227.0 | 1327.0 | 5.85 | 537.0 | 2997.0 | 5.58 | 620.0 | 3381.0 | 5.45 | |||||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2018 | 280 | 3+Praxis | 4837.0 | 26036.0 | 5.38 | 638.0 | 3402.0 | 5.33 | 848.0 | 4400.0 | 5.19 | 775.0 | 4030.0 | 5.20 | 306.0 | 1678.0 | 5.48 | 212.0 | 1169.0 | 5.51 | 100.0 | 548.0 | 5.48 | 45.0 | 218.0 | 4.84 | 32.0 | 135.0 | 4.22 | 239.0 | 1346.0 | 5.63 | 322.0 | 1825.0 | 5.67 | 465.0 | 2611.0 | 5.62 | 855.0 | 4674.0 | 5.47 | |||||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2017 | 280 | 4+Praxis | 4945.0 | 26942.0 | 5.45 | 893.0 | 4729.0 | 5.30 | 586.0 | 3184.0 | 5.43 | 537.0 | 2940.0 | 5.47 | 449.0 | 2496.0 | 5.56 | 281.0 | 1557.0 | 5.54 | 78.0 | 404.0 | 5.18 | 44.0 | 210.0 | 4.77 | 138.0 | 758.0 | 5.49 | 218.0 | 1255.0 | 5.76 | 366.0 | 2095.0 | 5.72 | 455.0 | 2494.0 | 5.48 | 900.0 | 4820.0 | 5.36 | |||||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2016 | 280 | 4+Praxis | 4741.0 | 26017.0 | 5.49 | 721.0 | 3926.0 | 5.45 | 618.0 | 3389.0 | 5.48 | 694.0 | 3778.0 | 5.44 | 536.0 | 2978.0 | 5.56 | 265.0 | 1474.0 | 5.56 | 188.0 | 1041.0 | 5.54 | 50.0 | 251.0 | 5.02 | 61.0 | 310.0 | 5.08 | 81.0 | 463.0 | 5.72 | 401.0 | 2276.0 | 5.68 | 482.0 | 2645.0 | 5.49 | 644.0 | 3486.0 | 5.41 | |||||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2015 | 280 | 4+Praxis | 4693.0 | 26141.0 | 5.57 | 675.0 | 3764.0 | 5.58 | 674.0 | 3660.0 | 5.43 | 647.0 | 3558.0 | 5.50 | 420.0 | 2343.0 | 5.58 | 270.0 | 1530.0 | 5.67 | 136.0 | 748.0 | 5.50 | 95.0 | 453.0 | 4.77 | 185.0 | 1076.0 | 5.82 | 402.0 | 2306.0 | 5.74 | 449.0 | 2546.0 | 5.67 | 740.0 | 4157.0 | 5.62 | ||||||||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2014 | 280 | 4+Praxis | 3771.0 | 20922.0 | 5.55 | 646.0 | 3592.0 | 5.56 | 483.0 | 2701.0 | 5.59 | 445.0 | 2486.0 | 5.59 | 287.0 | 1618.0 | 5.64 | 245.0 | 1334.0 | 5.44 | 88.0 | 431.0 | 4.90 | 63.0 | 281.0 | 4.46 | 126.0 | 672.0 | 5.33 | 116.0 | 623.0 | 5.37 | 230.0 | 1303.0 | 5.67 | 361.0 | 2065.0 | 5.72 | 681.0 | 3816.0 | 5.60 | |||||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2013 | 280 | 4+Praxis | 6059.0 | 25680.9 | 4.24 | 4951.0 | 19511.9 | 3.94 | 489.0 | 2782.0 | 5.69 | 619.0 | 3387.0 | 5.47 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2012 | 280 | 4+Praxis | 5175.0 | 22804.0 | 4.41 | 734.0 | 3527.0 | 4.81 | 997.0 | 4577.0 | 4.59 | 543.0 | 2633.0 | 4.85 | 462.0 | 2204.0 | 4.77 | 228.0 | 997.0 | 4.37 | 129.0 | 539.0 | 4.18 | 101.0 | 367.0 | 3.63 | 44.0 | 147.0 | 3.34 | 141.0 | 590.0 | 4.18 | 392.0 | 1101.0 | 2.81 | 552.0 | 2455.0 | 4.45 | 852.0 | 3667.0 | 4.30 | |||||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2011 | 280 | 4+Praxis | 4370.0 | 19649.0 | 1553 | 4.50 | 776.0 | 3501.0 | 4.51 | 631.0 | 2871.0 | 4.55 | 558.0 | 2529.0 | 4.53 | 285.0 | 1291.0 | 4.53 | 182.0 | 750.0 | 4.12 | 127.0 | 553.0 | 4.35 | 163.0 | 531.0 | 3.26 | 142.0 | 431.0 | 3.04 | 102.0 | 413.0 | 4.05 | 286.0 | 1395.0 | 4.88 | 475.0 | 2306.0 | 4.85 | 643.0 | 3078.0 | 1553 | 4.79 | |||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2010 | 280 | 4+Praxis | 5707.0 | 24786.0 | 4.34 | 903.0 | 3954.0 | 4.38 | 774.0 | 3421.0 | 4.42 | 659.0 | 2979.0 | 4.52 | 405.0 | 1866.0 | 4.61 | 329.0 | 1508.0 | 4.58 | 189.0 | 723.0 | 3.83 | 612.0 | 1955.0 | 3.19 | 395.0 | 1869.0 | 4.73 | 551.0 | 2578.0 | 4.68 | 890.0 | 3933.0 | 4.42 | |||||||||||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2009 | 280 | 4+Praxis | 5169.0 | 22547.0 | 4.36 | 985.0 | 4217.0 | 4.28 | 812.0 | 3548.0 | 4.37 | 742.0 | 3298.0 | 4.44 | 392.0 | 1756.0 | 4.48 | 269.0 | 1194.0 | 4.44 | 195.0 | 823.0 | 4.22 | 70.0 | 230.0 | 3.29 | 60.0 | 177.0 | 2.95 | 134.0 | 561.0 | 4.19 | 355.0 | 1589.0 | 4.48 | 459.0 | 2064.0 | 4.50 | 696.0 | 3090.0 | 4.44 | |||||||||||||||||||||||||
144 | Sole/Wasser | Stiebel-eltron | 9.9 | 2008 | 280 | 4+Praxis | 1444.0 | 6438.0 | 4.46 | 141.0 | 590.0 | 4.18 | 543.0 | 2491.0 | 4.59 | 760.0 | 3357.0 | 4.42 |
NR | 144 |
Username | schwotte |
Einbaujahr der WP | 2008-05-30 |
PLZ des Wohnortes | 75331 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Stiebel-eltron |
modulierend | Nein |
Leistung (0/35) | 9.9 kW |
berechneter Primärenergiebedarf | 110.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 128.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2200 Watt gem. |
elektr. Verbrauch HP gem./DB | 20 Watt |
elektr. Verbrauch WQ P gem./DB | 25 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | extern_geeicht |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 5.5 °C |
Heizung max. Vorlauf Temp. | 38.5 °C |
Spreizung Heizkr. | 9.5 |
Heizflaeche | 280 m² |
Lüftung | Fenster |
Personen | 2+ Praxis |
Grabenkollektor Helfer | Ja |
Grabenkollektor Erfahrung | bei Bekanntem die Planung für Erdkollektor Slinky gemacht , sehr steinig, wenig Platz, Haus Bj 1985 orginal, AZ >4 erwartet, AZ bei 4,5 |
Bemerkungen | Update 6/2021: wegen dem in der Corona-Zeit zusätzlichem Händewaschen der Patienten und aktiver WW-Zirkulationspumpe ist die WW-Anteil an der Wärmeerzeugung erheblich höher. Das wirkt sich signifikant auf die AZ aus da der WW-speicher statt 1-2x/Tag jetzt 5-7x/Tag aufgeheizt werden muss. Im Juni 2021 wurde nahezu auschließlich WW-erwärmt, eine WW-AZ von >4.5 ist aber nicht wirklich dramatisch schlecht. Update 5/2019: Heute hat sich die komplette Wärmepumpenanlage amortisiert! Incl. kalkulatorischem Zinseszins der Investitionskosten und bisher angefallenen Reparaturkosten (z.B. WW-Speicher & WP-Verdichter) Update 5/2018: Die Soletemperatur entwickelt sich wie von Fdl1409 berechnet. Ein von -"SHK-Fachleuten"- vorhergesagtes signifantes "Auskühlen" der Umgebung um die Sonden findet definitiv im Lauf der Jahre nicht statt, die Soleeingangstemperatur bleibt auch nach 10 Betriebsjahren konstant auch bei höchster Entzugsleistung (WP-Laufzeit >18 Std/Tag an kältesten Tagen, erfasst mit Datenlogger). Was aber wirklich überraschend ist: Die Sonden können auch weiterhin ohne Frostschutzmittel betrieben werden. Danke HTD und vor allem Fdl1409!!! |