Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1525 | Luft/Wasser | Nibe F750 | 6.0 | 2024 | 148 | 2 | 3667.0 | * | 1899.0 | 691.0 | 527.0 | 382.0 | 101.0 | 67.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1525 | Luft/Wasser | Nibe F750 | 6.0 | 2023 | 148 | 2 | 7552.0 | * | 1700.0 | 1510.0 | 1036.0 | 349.0 | 144.0 | 52.0 | 65.0 | 67.0 | 84.0 | 341.0 | 823.0 | 1381.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
1525 | Luft/Wasser | Nibe F750 | 6.0 | 2022 | 148 | 2 | 6960.0 | * | 1487.0 | 965.0 | 950.0 | 385.0 | 106.0 | 61.0 | 62.0 | 60.0 | 139.0 | 206.0 | 809.0 | 1730.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
1525 | Luft/Wasser | Nibe F750 | 6.0 | 2021 | 148 | 2 | 6887.0 | * | 1495.0 | 1065.0 | 741.0 | 384.0 | 169.0 | 89.0 | 72.0 | 72.0 | 105.0 | 352.0 | 956.0 | 1387.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
1525 | Luft/Wasser | Nibe F750 | 6.0 | 2020 | 148 | 2 | 5353.0 | * | 678.0 | 860.0 | 668.0 | 241.0 | 166.0 | 98.0 | 75.0 | 75.0 | 113.0 | 294.0 | 802.0 | 1283.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
1525 | Luft/Wasser | Nibe F750 | 6.0 | 2019 | 148 | 2 | 3860.0 | * | 1115.0 | 807.0 | 350.0 | 192.0 | 162.0 | 65.0 | 76.0 | 58.0 | 95.0 | 196.0 | 376.0 | 368.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
1525 | Luft/Wasser | Nibe F750 | 6.0 | 2018 | 148 | 2 | 4602.0 | * | 789.0 | 1126.0 | 690.0 | 281.0 | 79.0 | 72.0 | 75.0 | 60.0 | 108.0 | 237.0 | 435.0 | 650.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
1525 | Luft/Wasser | Nibe F750 | 6.0 | 2017 | 148 | 2 | 5910.0 | * | 1911.0 | 921.0 | 477.0 | 312.0 | 135.0 | 74.0 | 73.0 | 67.0 | 160.0 | 257.0 | 646.0 | 877.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
1525 | Luft/Wasser | Nibe F750 | 6.0 | 2016 | 148 | 2 | 5497.0 | * | 1200.0 | 741.0 | 665.0 | 280.0 | 136.0 | 77.0 | 78.0 | 66.0 | 100.0 | 410.0 | 683.0 | 1061.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
1525 | Luft/Wasser | Nibe F750 | 6.0 | 2015 | 148 | 2 | 5350.0 | * | 1070.0 | 1182.0 | 471.0 | 347.0 | 159.0 | 111.0 | 83.0 | 97.0 | 151.0 | 416.0 | 548.0 | 715.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
1525 | Luft/Wasser | Nibe F750 | 6.0 | 2014 | 148 | 2 | 5240.0 | * | 1147.0 | 876.0 | 495.0 | 214.0 | 191.0 | 97.0 | 78.0 | 56.0 | 123.0 | 274.0 | 710.0 | 979.0 |
NR | 1525 |
Username | flipflop |
Einbaujahr der WP | 2013-10-01 |
PLZ des Wohnortes | 93138 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe F750 |
modulierend | |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 49.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Abluft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 148 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |